There is a typo in document "Monitoring OSDs and PGs" as below
An OSD was ``down``, was restared, and is now ``recovering``.
This patch corrects 'restared' to 'restarted'. The whole code base
is also searched to ensure there is no more 'restared'.
Signed-off-by: Yilong Zhao <accelazh@gmail.com>
ceph osd pool set $POOL scrub_min_interval N
ceph osd pool set $POOL scrub_max_interval N
ceph osd pool set $POOL deep_scrub_interval N
If N > 0, this value is used for the pool instead of
the corresponding global parameter from the config
(osd_scrub_min_interval, osd_scrub_max_interval or
osd_deep_scrub_interval).
Fixes: #13077
Signed-off-by: Mykola Golub <mgolub@mirantis.com>
This reverts commit 30810da4b5.
After some discussion we have decided it is better to build a generic
dictionary in pg_pool_t to store infrequently used per-pool properties.
Signed-off-by: Sage Weil <sage@redhat.com>
ceph osd pool set $POOL scrub_min_interval N
ceph osd pool set $POOL scrub_max_interval N
ceph osd pool set $POOL deep_scrub_interval N
If N > 0, this value is used for the pool instead of
the corresponding global parameter from the config
(osd_scrub_min_interval, osd_scrub_max_interval or
osd_deep_scrub_interval).
Fixes: #13077
Signed-off-by: Mykola Golub <mgolub@mirantis.com>
These haven't existed since 0.84 -- the cephfs documentation
was updated at the time, but there were also references in the
rados documentation.
Signed-off-by: John Spray <john.spray@redhat.com>
always indent using tab, the rendered html looks good, but it helps with
editor to highlight the codeblock properly.
Signed-off-by: Kefu Chai <kchai@redhat.com>
doc/rados/operations/add-or-rm-mons: simplify the steps to add a mon
Reviewed-by: Joao Eduardo Luis <joao@suse.de>
Reviewed-by: Sage Weil <sage@redhat.com>
Reviewed-by: Loic Dachary <ldachary@redhat.com>
this change removes the step to "ceph mon add" before starting a new
monitor. because the existing leader will start an election at seeing
the MMonJoin message sent by the new joiner, after the quorum is
archieved, the monmap will be updated with the new monitor.
so, "ceph mon add" is not necessary to add a new monitor.
moreover, this command will be blocked until a new quorum is formed,
and the proposed monmap is accepted. but in case of adding a monitor
to a single monitor cluster, the leader will wait until at least two
of the monitors reply to it. apparently, this does not happen unless
the new monitor starts. so from the user's point of view, this
command hangs until timesout, if he/she does not start the mon.b
beforehand. but this is an expected behaviour.
so, to avoid this confusion and simplify the steps to add a new
monitor. we'd better simply remove this "ceph mon add" step.
Fixes: #12620
Signed-off-by: Kefu Chai <kchai@redhat.com>
I put in doc/rados/api/python.rst line numbers on every code samples in
order to make them look all the same.
Fixes: #12174
Signed off: Pierre Chaumont pierre.chaumont31@gmail.com
Wip writeback throttling for cache tiering
This patch is to do write back throttling for cache tiering, which is similar to what the Linux kernel does for page cache write back. A paramter 'cache_target_dirty_high_ratio' (default 0.6) is introduced as the high speed flushing threshold, while leave the 'cache_target_dirty_ratio' (default 0.4) to represent the low speed threshold. The flush speed is controlled by limiting the parallelism of flushing. The maximum parallelism under low speed is half of the parallelism under high speed. If there is at least one PG such that the dirty ratio beyond the high threshold, full speed mode is entered; If there is no PG such that dirty ratio beyond the low threshold, idle mode is entered; In other cases, slow speed mode is entered.
Signed-off-by: Mingxin Liu <mingxinliu@ubuntukylin.com>
Reviewed-by: Li Wang <liwang@ubuntukylin.com>
Suggested-by: Nick Fisk <nick@fisk.me.uk>
Tested-by: Kefu Chai <kchai@redhat.com>