image: add FACTORY_SIZE to DEFAULT_DEVICE_VARS
FACTORY_SIZE is used as a device recipe variable on both the D-Link DIR-825-B1 and Trendnet TEW-673GRU, but is not listed as a device variable, neither globally, nor for ath79. Being assigned the same value, this probably hasn't caused any issues. Add FACTORY_SIZE to the global list DEFAULT_DEVICE_VARS, to ensure the variable is reset for every device, and to allow it to be used outside of the ath79 target. Signed-off-by: Sander Vanheule <sander@svanheule.net>
This commit is contained in:
parent
753efd45b2
commit
e5fe401908
|
@ -419,7 +419,7 @@ DEFAULT_DEVICE_VARS := \
|
|||
DEVICE_FDT_NUM DEVICE_IMG_PREFIX SOC BOARD_NAME UIMAGE_MAGIC UIMAGE_NAME \
|
||||
SUPPORTED_DEVICES IMAGE_METADATA KERNEL_ENTRY KERNEL_LOADADDR \
|
||||
UBOOT_PATH IMAGE_SIZE \
|
||||
FACTORY_IMG_NAME \
|
||||
FACTORY_IMG_NAME FACTORY_SIZE \
|
||||
DEVICE_PACKAGES DEVICE_COMPAT_VERSION DEVICE_COMPAT_MESSAGE \
|
||||
DEVICE_VENDOR DEVICE_MODEL DEVICE_VARIANT \
|
||||
DEVICE_ALT0_VENDOR DEVICE_ALT0_MODEL DEVICE_ALT0_VARIANT \
|
||||
|
|
Loading…