98 lines
2.7 KiB
Go
98 lines
2.7 KiB
Go
//go:build windows
|
|
// +build windows
|
|
|
|
package collector
|
|
|
|
import (
|
|
"errors"
|
|
"strconv"
|
|
"strings"
|
|
|
|
"github.com/StackExchange/wmi"
|
|
"github.com/prometheus-community/windows_exporter/log"
|
|
"github.com/prometheus/client_golang/prometheus"
|
|
)
|
|
|
|
func init() {
|
|
registerCollector("cpu_info", newCpuInfoCollector)
|
|
}
|
|
|
|
// If you are adding additional labels to the metric, make sure that they get added in here as well. See below for explanation.
|
|
const (
|
|
win32ProcessorQuery = "SELECT Architecture, DeviceId, Description, Family, L2CacheSize, L3CacheSize, Name FROM Win32_Processor"
|
|
)
|
|
|
|
// A CpuInfoCollector is a Prometheus collector for a few WMI metrics in Win32_Processor
|
|
type CpuInfoCollector struct {
|
|
CpuInfo *prometheus.Desc
|
|
}
|
|
|
|
func newCpuInfoCollector() (Collector, error) {
|
|
return &CpuInfoCollector{
|
|
CpuInfo: prometheus.NewDesc(
|
|
prometheus.BuildFQName(Namespace, "", "cpu_info"),
|
|
"Labeled CPU information as provided provided by Win32_Processor",
|
|
[]string{
|
|
"architecture",
|
|
"device_id",
|
|
"description",
|
|
"family",
|
|
"l2_cache_size",
|
|
"l3_cache_size",
|
|
"name"},
|
|
nil,
|
|
),
|
|
}, nil
|
|
}
|
|
|
|
type win32_Processor struct {
|
|
Architecture uint32
|
|
DeviceID string
|
|
Description string
|
|
Family uint16
|
|
L2CacheSize uint32
|
|
L3CacheSize uint32
|
|
Name string
|
|
}
|
|
|
|
// Collect sends the metric values for each metric
|
|
// to the provided prometheus Metric channel.
|
|
func (c *CpuInfoCollector) Collect(ctx *ScrapeContext, ch chan<- prometheus.Metric) error {
|
|
if desc, err := c.collect(ch); err != nil {
|
|
log.Error("failed collecting cpu_info metrics:", desc, err)
|
|
return err
|
|
}
|
|
return nil
|
|
}
|
|
|
|
func (c *CpuInfoCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
|
|
var dst []win32_Processor
|
|
// We use a static query here because the provided methods in wmi.go all issue a SELECT *;
|
|
// This results in the time consuming LoadPercentage field being read which seems to measure each CPU
|
|
// serially over a 1 second interval, so the scrape time is at least 1s * num_sockets
|
|
if err := wmi.Query(win32ProcessorQuery, &dst); err != nil {
|
|
return nil, err
|
|
}
|
|
if len(dst) == 0 {
|
|
return nil, errors.New("WMI query returned empty result set")
|
|
}
|
|
|
|
// Some CPUs end up exposing trailing spaces for certain strings, so clean them up
|
|
for _, processor := range dst {
|
|
ch <- prometheus.MustNewConstMetric(
|
|
c.CpuInfo,
|
|
prometheus.GaugeValue,
|
|
1.0,
|
|
strconv.Itoa(int(processor.Architecture)),
|
|
strings.TrimRight(processor.DeviceID, " "),
|
|
strings.TrimRight(processor.Description, " "),
|
|
strconv.Itoa(int(processor.Family)),
|
|
strconv.Itoa(int(processor.L2CacheSize)),
|
|
strconv.Itoa(int(processor.L3CacheSize)),
|
|
strings.TrimRight(processor.Name, " "),
|
|
)
|
|
}
|
|
|
|
return nil, nil
|
|
}
|