windows_exporter/collector/cpu_info.go

97 lines
2.6 KiB
Go

// +build windows
package collector
import (
"errors"
"strconv"
"strings"
"github.com/StackExchange/wmi"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/common/log"
)
func init() {
registerCollector("cpu_info", newCpuInfoCollector)
}
// If you are adding additional labels to the metric, make sure that they get added in here as well. See below for explanation.
const (
win32ProcessorQuery = "SELECT Architecture, DeviceId, Description, Family, L2CacheSize, L3CacheSize, Name FROM Win32_Processor"
)
// A CpuInfoCollector is a Prometheus collector for a few WMI metrics in Win32_Processor
type CpuInfoCollector struct {
CpuInfo *prometheus.Desc
}
func newCpuInfoCollector() (Collector, error) {
return &CpuInfoCollector{
CpuInfo: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, "", "cpu_info"),
"Labeled CPU information as provided provided by Win32_Processor",
[]string{
"architecture",
"device_id",
"description",
"family",
"l2_cache_size",
"l3_cache_size",
"name"},
nil,
),
}, nil
}
type win32_Processor struct {
Architecture uint32
DeviceID string
Description string
Family uint16
L2CacheSize uint32
L3CacheSize uint32
Name string
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *CpuInfoCollector) Collect(ctx *ScrapeContext, ch chan<- prometheus.Metric) error {
if desc, err := c.collect(ch); err != nil {
log.Error("failed collecting cpu_info metrics:", desc, err)
return err
}
return nil
}
func (c *CpuInfoCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []win32_Processor
// We use a static query here because the provided methods in wmi.go all issue a SELECT *;
// This results in the time consuming LoadPercentage field being read which seems to measure each CPU
// serially over a 1 second interval, so the scrape time is at least 1s * num_sockets
if err := wmi.Query(win32ProcessorQuery, &dst); err != nil {
return nil, err
}
if len(dst) == 0 {
return nil, errors.New("WMI query returned empty result set")
}
// Some CPUs end up exposing trailing spaces for certain strings, so clean them up
for _, processor := range dst {
ch <- prometheus.MustNewConstMetric(
c.CpuInfo,
prometheus.GaugeValue,
1.0,
strconv.Itoa(int(processor.Architecture)),
strings.TrimRight(processor.DeviceID, " "),
strings.TrimRight(processor.Description, " "),
strconv.Itoa(int(processor.Family)),
strconv.Itoa(int(processor.L2CacheSize)),
strconv.Itoa(int(processor.L3CacheSize)),
strings.TrimRight(processor.Name, " "),
)
}
return nil, nil
}