windows_exporter/collector/system.go

128 lines
3.9 KiB
Go

//go:build windows
// +build windows
package collector
import (
"github.com/go-kit/log"
"github.com/go-kit/log/level"
"github.com/prometheus/client_golang/prometheus"
)
// A SystemCollector is a Prometheus collector for WMI metrics
type SystemCollector struct {
logger log.Logger
ContextSwitchesTotal *prometheus.Desc
ExceptionDispatchesTotal *prometheus.Desc
ProcessorQueueLength *prometheus.Desc
SystemCallsTotal *prometheus.Desc
SystemUpTime *prometheus.Desc
Threads *prometheus.Desc
}
// newSystemCollector ...
func newSystemCollector(logger log.Logger) (Collector, error) {
const subsystem = "system"
return &SystemCollector{
logger: log.With(logger, "collector", subsystem),
ContextSwitchesTotal: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "context_switches_total"),
"Total number of context switches (WMI source: PerfOS_System.ContextSwitchesPersec)",
nil,
nil,
),
ExceptionDispatchesTotal: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "exception_dispatches_total"),
"Total number of exceptions dispatched (WMI source: PerfOS_System.ExceptionDispatchesPersec)",
nil,
nil,
),
ProcessorQueueLength: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "processor_queue_length"),
"Length of processor queue (WMI source: PerfOS_System.ProcessorQueueLength)",
nil,
nil,
),
SystemCallsTotal: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "system_calls_total"),
"Total number of system calls (WMI source: PerfOS_System.SystemCallsPersec)",
nil,
nil,
),
SystemUpTime: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "system_up_time"),
"System boot time (WMI source: PerfOS_System.SystemUpTime)",
nil,
nil,
),
Threads: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "threads"),
"Current number of threads (WMI source: PerfOS_System.Threads)",
nil,
nil,
),
}, nil
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *SystemCollector) Collect(ctx *ScrapeContext, ch chan<- prometheus.Metric) error {
if desc, err := c.collect(ctx, ch); err != nil {
_ = level.Error(c.logger).Log("failed collecting system metrics", "desc", desc, "err", err)
return err
}
return nil
}
// Win32_PerfRawData_PerfOS_System docs:
// - https://web.archive.org/web/20050830140516/http://msdn.microsoft.com/library/en-us/wmisdk/wmi/win32_perfrawdata_perfos_system.asp
type system struct {
ContextSwitchesPersec float64 `perflib:"Context Switches/sec"`
ExceptionDispatchesPersec float64 `perflib:"Exception Dispatches/sec"`
ProcessorQueueLength float64 `perflib:"Processor Queue Length"`
SystemCallsPersec float64 `perflib:"System Calls/sec"`
SystemUpTime float64 `perflib:"System Up Time"`
Threads float64 `perflib:"Threads"`
}
func (c *SystemCollector) collect(ctx *ScrapeContext, ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []system
if err := unmarshalObject(ctx.perfObjects["System"], &dst, c.logger); err != nil {
return nil, err
}
ch <- prometheus.MustNewConstMetric(
c.ContextSwitchesTotal,
prometheus.CounterValue,
dst[0].ContextSwitchesPersec,
)
ch <- prometheus.MustNewConstMetric(
c.ExceptionDispatchesTotal,
prometheus.CounterValue,
dst[0].ExceptionDispatchesPersec,
)
ch <- prometheus.MustNewConstMetric(
c.ProcessorQueueLength,
prometheus.GaugeValue,
dst[0].ProcessorQueueLength,
)
ch <- prometheus.MustNewConstMetric(
c.SystemCallsTotal,
prometheus.CounterValue,
dst[0].SystemCallsPersec,
)
ch <- prometheus.MustNewConstMetric(
c.SystemUpTime,
prometheus.GaugeValue,
dst[0].SystemUpTime,
)
ch <- prometheus.MustNewConstMetric(
c.Threads,
prometheus.GaugeValue,
dst[0].Threads,
)
return nil, nil
}