windows_exporter/collector/vmware.go
2019-01-23 09:56:24 +01:00

345 lines
8.0 KiB
Go

// +build windows
package collector
import (
"errors"
"github.com/StackExchange/wmi"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/common/log"
)
func init() {
Factories["vmware"] = NewVmwareCollector
}
// A VmwareCollector is a Prometheus collector for WMI Win32_PerfRawData_vmGuestLib_VMem/Win32_PerfRawData_vmGuestLib_VCPU metrics
type VmwareCollector struct {
MemActive *prometheus.Desc
MemBallooned *prometheus.Desc
MemLimit *prometheus.Desc
MemMapped *prometheus.Desc
MemOverhead *prometheus.Desc
MemReservation *prometheus.Desc
MemShared *prometheus.Desc
MemSharedSaved *prometheus.Desc
MemShares *prometheus.Desc
MemSwapped *prometheus.Desc
MemTargetSize *prometheus.Desc
MemUsed *prometheus.Desc
CpuLimitMHz *prometheus.Desc
CpuReservationMHz *prometheus.Desc
CpuShares *prometheus.Desc
CpuStolenTotal *prometheus.Desc
CpuTimeTotal *prometheus.Desc
EffectiveVMSpeedMHz *prometheus.Desc
HostProcessorSpeedMHz *prometheus.Desc
}
// NewVmwareCollector constructs a new VmwareCollector
func NewVmwareCollector() (Collector, error) {
const subsystem = "vmware"
return &VmwareCollector{
MemActive: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_active_bytes"),
"(MemActiveMB)",
nil,
nil,
),
MemBallooned: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_ballooned_bytes"),
"(MemBalloonedMB)",
nil,
nil,
),
MemLimit: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_limit_bytes"),
"(MemLimitMB)",
nil,
nil,
),
MemMapped: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_mapped_bytes"),
"(MemMappedMB)",
nil,
nil,
),
MemOverhead: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_overhead_bytes"),
"(MemOverheadMB)",
nil,
nil,
),
MemReservation: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_reservation_bytes"),
"(MemReservationMB)",
nil,
nil,
),
MemShared: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_shared_bytes"),
"(MemSharedMB)",
nil,
nil,
),
MemSharedSaved: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_shared_saved_bytes"),
"(MemSharedSavedMB)",
nil,
nil,
),
MemShares: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_shares"),
"(MemShares)",
nil,
nil,
),
MemSwapped: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_swapped_bytes"),
"(MemSwappedMB)",
nil,
nil,
),
MemTargetSize: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_target_size_bytes"),
"(MemTargetSizeMB)",
nil,
nil,
),
MemUsed: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "mem_used_bytes"),
"(MemUsedMB)",
nil,
nil,
),
CpuLimitMHz: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "cpu_limit_mhz"),
"(CpuLimitMHz)",
nil,
nil,
),
CpuReservationMHz: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "cpu_reservation_mhz"),
"(CpuReservationMHz)",
nil,
nil,
),
CpuShares: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "cpu_shares"),
"(CpuShares)",
nil,
nil,
),
CpuStolenTotal: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "cpu_stolen_seconds_total"),
"(CpuStolenMs)",
nil,
nil,
),
CpuTimeTotal: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "cpu_time_seconds_total"),
"(CpuTimePercents)",
nil,
nil,
),
EffectiveVMSpeedMHz: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "effective_vm_speed_mhz"),
"(EffectiveVMSpeedMHz)",
nil,
nil,
),
HostProcessorSpeedMHz: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "host_processor_speed_mhz"),
"(HostProcessorSpeedMHz)",
nil,
nil,
),
}, nil
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *VmwareCollector) Collect(ch chan<- prometheus.Metric) error {
if desc, err := c.collectMem(ch); err != nil {
log.Error("failed collecting vmware memory metrics:", desc, err)
return err
}
if desc, err := c.collectCpu(ch); err != nil {
log.Error("failed collecting vmware cpu metrics:", desc, err)
return err
}
return nil
}
type Win32_PerfRawData_vmGuestLib_VMem struct {
MemActiveMB uint64
MemBalloonedMB uint64
MemLimitMB uint64
MemMappedMB uint64
MemOverheadMB uint64
MemReservationMB uint64
MemSharedMB uint64
MemSharedSavedMB uint64
MemShares uint64
MemSwappedMB uint64
MemTargetSizeMB uint64
MemUsedMB uint64
}
type Win32_PerfRawData_vmGuestLib_VCPU struct {
CpuLimitMHz uint64
CpuReservationMHz uint64
CpuShares uint64
CpuStolenMs uint64
CpuTimePercents uint64
EffectiveVMSpeedMHz uint64
HostProcessorSpeedMHz uint64
}
func (c *VmwareCollector) collectMem(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []Win32_PerfRawData_vmGuestLib_VMem
q := queryAll(&dst)
if err := wmi.Query(q, &dst); err != nil {
return nil, err
}
if len(dst) == 0 {
return nil, errors.New("WMI query returned empty result set")
}
ch <- prometheus.MustNewConstMetric(
c.MemActive,
prometheus.GaugeValue,
mbToBytes(dst[0].MemActiveMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemBallooned,
prometheus.GaugeValue,
mbToBytes(dst[0].MemBalloonedMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemLimit,
prometheus.GaugeValue,
mbToBytes(dst[0].MemLimitMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemMapped,
prometheus.GaugeValue,
mbToBytes(dst[0].MemMappedMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemOverhead,
prometheus.GaugeValue,
mbToBytes(dst[0].MemOverheadMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemReservation,
prometheus.GaugeValue,
mbToBytes(dst[0].MemReservationMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemShared,
prometheus.GaugeValue,
mbToBytes(dst[0].MemSharedMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemSharedSaved,
prometheus.GaugeValue,
mbToBytes(dst[0].MemSharedSavedMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemShares,
prometheus.GaugeValue,
float64(dst[0].MemShares),
)
ch <- prometheus.MustNewConstMetric(
c.MemSwapped,
prometheus.GaugeValue,
mbToBytes(dst[0].MemSwappedMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemTargetSize,
prometheus.GaugeValue,
mbToBytes(dst[0].MemTargetSizeMB),
)
ch <- prometheus.MustNewConstMetric(
c.MemUsed,
prometheus.GaugeValue,
mbToBytes(dst[0].MemUsedMB),
)
return nil, nil
}
func mbToBytes(mb uint64) float64 {
return float64(mb * 1024 * 1024)
}
func (c *VmwareCollector) collectCpu(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []Win32_PerfRawData_vmGuestLib_VCPU
q := queryAll(&dst)
if err := wmi.Query(q, &dst); err != nil {
return nil, err
}
if len(dst) == 0 {
return nil, errors.New("WMI query returned empty result set")
}
ch <- prometheus.MustNewConstMetric(
c.CpuLimitMHz,
prometheus.GaugeValue,
float64(dst[0].CpuLimitMHz),
)
ch <- prometheus.MustNewConstMetric(
c.CpuReservationMHz,
prometheus.GaugeValue,
float64(dst[0].CpuReservationMHz),
)
ch <- prometheus.MustNewConstMetric(
c.CpuShares,
prometheus.GaugeValue,
float64(dst[0].CpuShares),
)
ch <- prometheus.MustNewConstMetric(
c.CpuStolenTotal,
prometheus.CounterValue,
float64(dst[0].CpuStolenMs)*ticksToSecondsScaleFactor,
)
ch <- prometheus.MustNewConstMetric(
c.CpuTimeTotal,
prometheus.CounterValue,
float64(dst[0].CpuTimePercents)*ticksToSecondsScaleFactor,
)
ch <- prometheus.MustNewConstMetric(
c.EffectiveVMSpeedMHz,
prometheus.GaugeValue,
float64(dst[0].EffectiveVMSpeedMHz),
)
ch <- prometheus.MustNewConstMetric(
c.HostProcessorSpeedMHz,
prometheus.GaugeValue,
float64(dst[0].HostProcessorSpeedMHz),
)
return nil, nil
}