Added thermal zone information and documentation

This commit is contained in:
Stewart Thomson 2019-07-12 14:54:20 -04:00
parent 56be7c63d5
commit c73f52338d
3 changed files with 137 additions and 0 deletions

View File

@ -33,6 +33,7 @@ Name | Description | Enabled by default
[service](docs/collector.service.md) | Service state metrics | ✓ [service](docs/collector.service.md) | Service state metrics | ✓
[system](docs/collector.system.md) | System calls | ✓ [system](docs/collector.system.md) | System calls | ✓
[tcp](docs/collector.tcp.md) | TCP connections | [tcp](docs/collector.tcp.md) | TCP connections |
[thermalzone](docs/collector.thermalzone.md) | Thermal information
[textfile](docs/collector.textfile.md) | Read prometheus metrics from a text file | ✓ [textfile](docs/collector.textfile.md) | Read prometheus metrics from a text file | ✓
[vmware](docs/collector.vmware.md) | Performance counters installed by the Vmware Guest agent | [vmware](docs/collector.vmware.md) | Performance counters installed by the Vmware Guest agent |

105
collector/thermalzone.go Normal file
View File

@ -0,0 +1,105 @@
package collector
import (
"github.com/StackExchange/wmi"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/common/log"
)
func init() {
Factories["thermalzone"] = NewThermalZoneCollector
}
// A ThermalZoneCollector is a Prometheus collector for WMI Win32_PerfRawData_Counters_ThermalZoneInformation metrics
type ThermalZoneCollector struct {
HighPrecisionTemperature *prometheus.Desc
PercentPassiveLimit *prometheus.Desc
Temperature *prometheus.Desc
ThrottleReasons *prometheus.Desc
}
// NewThermalZoneCollector ...
func NewThermalZoneCollector() (Collector, error) {
const subsystem = "thermalzone"
return &ThermalZoneCollector{
HighPrecisionTemperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "high_precision_temperature"),
"(HighPrecisionTemperature)",
nil,
nil,
),
PercentPassiveLimit: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "percent_passive_limit"),
"(PercentPassiveLimit)",
nil,
nil,
),
Temperature: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "temperature"),
"(Temperature)",
nil,
nil,
),
ThrottleReasons: prometheus.NewDesc(
prometheus.BuildFQName(Namespace, subsystem, "throttle_reasons"),
"(ThrottleReasons)",
nil,
nil,
),
}, nil
}
// Collect sends the metric values for each metric
// to the provided prometheus Metric channel.
func (c *ThermalZoneCollector) Collect(ch chan<- prometheus.Metric) error {
if desc, err := c.collect(ch); err != nil {
log.Error("failed collecting thermalzone metrics:", desc, err)
return err
}
return nil
}
// Win32_PerfRawData_Counters_ThermalZoneInformation docs:
// - <add link to documentation here>
type Win32_PerfRawData_Counters_ThermalZoneInformation struct {
Name string
HighPrecisionTemperature uint32
PercentPassiveLimit uint32
Temperature uint32
ThrottleReasons uint32
}
func (c *ThermalZoneCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
var dst []Win32_PerfRawData_Counters_ThermalZoneInformation
q := queryAll(&dst)
if err := wmi.Query(q, &dst); err != nil {
return nil, err
}
ch <- prometheus.MustNewConstMetric(
c.HighPrecisionTemperature,
prometheus.GaugeValue,
float64(dst[0].HighPrecisionTemperature),
)
ch <- prometheus.MustNewConstMetric(
c.PercentPassiveLimit,
prometheus.GaugeValue,
float64(dst[0].PercentPassiveLimit),
)
ch <- prometheus.MustNewConstMetric(
c.Temperature,
prometheus.GaugeValue,
float64(dst[0].Temperature),
)
ch <- prometheus.MustNewConstMetric(
c.ThrottleReasons,
prometheus.GaugeValue,
float64(dst[0].ThrottleReasons),
)
return nil, nil
}

View File

@ -0,0 +1,31 @@
# tcp collector
The thermalzone collector exposes metrics about system temps. Note that temperature is given in Kelvin
|||
-|-
Metric name prefix | `thermalzone`
Classes | [`Win32_PerfRawData_Counters_ThermalZoneInformation`](https://msdn.microsoft.com/en-us/library/aa394341(v=vs.85).aspx)
Enabled by default? | No
## Flags
None
## Metrics
Name | Description | Type | Labels
-----|-------------|------|-------
`wmi_thermalzone_high_precision_temperature` | _Not yet documented_ | gauge | None
`wmi_thermalzone_percent_passive_limit` | _Not yet documented_ | gauge | None
`wmi_thermalzone_temperature ` | _Not yet documented_ | gauge | None
`wmi_thermalzone_throttle_reasons ` | _Not yet documented_ | gauge | None
### Example metric
_This collector does not yet have explained examples, we would appreciate your help adding them!_
## Useful queries
_This collector does not yet have any useful queries added, we would appreciate your help adding them!_
## Alerting examples