Add a cpu_info collector
The cpu_info collector exposes a single metric per socket with some information on installed CPUs, somewhat like the node_cpu_info metric Signed-off-by: Steffen Higel <higels@valvesoftware.com>
This commit is contained in:
parent
648b6e0ab5
commit
7086e0f627
|
@ -12,6 +12,7 @@ Name | Description | Enabled by default
|
||||||
[ad](docs/collector.ad.md) | Active Directory Domain Services |
|
[ad](docs/collector.ad.md) | Active Directory Domain Services |
|
||||||
[adfs](docs/collector.adfs.md) | Active Directory Federation Services |
|
[adfs](docs/collector.adfs.md) | Active Directory Federation Services |
|
||||||
[cpu](docs/collector.cpu.md) | CPU usage | ✓
|
[cpu](docs/collector.cpu.md) | CPU usage | ✓
|
||||||
|
[cpu_info](docs/collector.cpu_info.md) | CPU Information |
|
||||||
[cs](docs/collector.cs.md) | "Computer System" metrics (system properties, num cpus/total memory) | ✓
|
[cs](docs/collector.cs.md) | "Computer System" metrics (system properties, num cpus/total memory) | ✓
|
||||||
[container](docs/collector.container.md) | Container metrics |
|
[container](docs/collector.container.md) | Container metrics |
|
||||||
[dfsr](docs/collector.dfsr.md) | DFSR metrics |
|
[dfsr](docs/collector.dfsr.md) | DFSR metrics |
|
||||||
|
|
|
@ -0,0 +1,96 @@
|
||||||
|
// +build windows
|
||||||
|
|
||||||
|
package collector
|
||||||
|
|
||||||
|
import (
|
||||||
|
"errors"
|
||||||
|
"strconv"
|
||||||
|
"strings"
|
||||||
|
|
||||||
|
"github.com/StackExchange/wmi"
|
||||||
|
"github.com/prometheus/client_golang/prometheus"
|
||||||
|
"github.com/prometheus/common/log"
|
||||||
|
)
|
||||||
|
|
||||||
|
func init() {
|
||||||
|
registerCollector("cpu_info", newCpuInfoCollector)
|
||||||
|
}
|
||||||
|
|
||||||
|
// If you are adding additional labels to the metric, make sure that they get added in here as well. See below for explanation.
|
||||||
|
const (
|
||||||
|
win32ProcessorQuery = "SELECT Architecture, DeviceId, Description, Family, L2CacheSize, L3CacheSize, Name FROM Win32_Processor"
|
||||||
|
)
|
||||||
|
|
||||||
|
// A CpuInfoCollector is a Prometheus collector for a few WMI metrics in Win32_Processor
|
||||||
|
type CpuInfoCollector struct {
|
||||||
|
CpuInfo *prometheus.Desc
|
||||||
|
}
|
||||||
|
|
||||||
|
func newCpuInfoCollector() (Collector, error) {
|
||||||
|
return &CpuInfoCollector{
|
||||||
|
CpuInfo: prometheus.NewDesc(
|
||||||
|
prometheus.BuildFQName(Namespace, "", "cpu_info"),
|
||||||
|
"Labeled CPU information as provided provided by Win32_Processor",
|
||||||
|
[]string{
|
||||||
|
"architecture",
|
||||||
|
"device_id",
|
||||||
|
"description",
|
||||||
|
"family",
|
||||||
|
"l2_cache_size",
|
||||||
|
"l3_cache_size",
|
||||||
|
"name"},
|
||||||
|
nil,
|
||||||
|
),
|
||||||
|
}, nil
|
||||||
|
}
|
||||||
|
|
||||||
|
type win32_Processor struct {
|
||||||
|
Architecture uint32
|
||||||
|
DeviceID string
|
||||||
|
Description string
|
||||||
|
Family uint16
|
||||||
|
L2CacheSize uint32
|
||||||
|
L3CacheSize uint32
|
||||||
|
Name string
|
||||||
|
}
|
||||||
|
|
||||||
|
// Collect sends the metric values for each metric
|
||||||
|
// to the provided prometheus Metric channel.
|
||||||
|
func (c *CpuInfoCollector) Collect(ctx *ScrapeContext, ch chan<- prometheus.Metric) error {
|
||||||
|
if desc, err := c.collect(ch); err != nil {
|
||||||
|
log.Error("failed collecting cpu_info metrics:", desc, err)
|
||||||
|
return err
|
||||||
|
}
|
||||||
|
return nil
|
||||||
|
}
|
||||||
|
|
||||||
|
func (c *CpuInfoCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
|
||||||
|
var dst []win32_Processor
|
||||||
|
// We use a static query here because the provided methods in wmi.go all issue a SELECT *;
|
||||||
|
// This results in the time consuming LoadPercentage field being read which seems to measure each CPU
|
||||||
|
// serially over a 1 second interval, so the scrape time is at least 1s * num_sockets
|
||||||
|
if err := wmi.Query(win32ProcessorQuery, &dst); err != nil {
|
||||||
|
return nil, err
|
||||||
|
}
|
||||||
|
if len(dst) == 0 {
|
||||||
|
return nil, errors.New("WMI query returned empty result set")
|
||||||
|
}
|
||||||
|
|
||||||
|
// Some CPUs end up exposing trailing spaces for certain strings, so clean them up
|
||||||
|
for _, processor := range dst {
|
||||||
|
ch <- prometheus.MustNewConstMetric(
|
||||||
|
c.CpuInfo,
|
||||||
|
prometheus.GaugeValue,
|
||||||
|
1.0,
|
||||||
|
strconv.Itoa(int(processor.Architecture)),
|
||||||
|
strings.TrimRight(processor.DeviceID, " "),
|
||||||
|
strings.TrimRight(processor.Description, " "),
|
||||||
|
strconv.Itoa(int(processor.Family)),
|
||||||
|
strconv.Itoa(int(processor.L2CacheSize)),
|
||||||
|
strconv.Itoa(int(processor.L3CacheSize)),
|
||||||
|
strings.TrimRight(processor.Name, " "),
|
||||||
|
)
|
||||||
|
}
|
||||||
|
|
||||||
|
return nil, nil
|
||||||
|
}
|
|
@ -0,0 +1,31 @@
|
||||||
|
# cpu_info collector
|
||||||
|
|
||||||
|
The cpu_info collector exposes metrics detailing a per-socket breakdown of the Processors in the system
|
||||||
|
|
||||||
|
|||
|
||||||
|
-|-
|
||||||
|
Metric name prefix | `cpu_info`
|
||||||
|
Classes | [`Win32_Processor`](https://docs.microsoft.com/en-us/windows/win32/cimwin32prov/win32-processor)
|
||||||
|
Enabled by default? | No
|
||||||
|
|
||||||
|
## Flags
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
## Metrics
|
||||||
|
|
||||||
|
Name | Description | Type | Labels
|
||||||
|
-----|-------------|------|-------
|
||||||
|
`windows_cpu_info` | Labeled CPU information | gauge | `architecture`, `device_id`, `description`, `family`, `l2_cache_size` `l3_cache_size`, `name`
|
||||||
|
|
||||||
|
### Example metric
|
||||||
|
```
|
||||||
|
windows_cpu_info{architecture="9",description="AMD64 Family 23 Model 49 Stepping 0",device_id="CPU0",family="107",l2_cache_size="32768",l3_cache_size="262144",name="AMD EPYC 7702P 64-Core Processor"} 1
|
||||||
|
```
|
||||||
|
The value of the metric is irrelevant, but the labels expose some useful information on the CPU installed in each socket.
|
||||||
|
|
||||||
|
## Useful queries
|
||||||
|
_This collector does not yet have any useful queries added, we would appreciate your help adding them!_
|
||||||
|
|
||||||
|
## Alerting examples
|
||||||
|
_This collector does not yet have alerting examples, we would appreciate your help adding them!_
|
Loading…