mirror of
https://github.com/prometheus-community/windows_exporter
synced 2025-02-19 13:37:09 +00:00
Merge pull request #359 from StewartThomson/thermalzone
Added thermal zone information and documentation
This commit is contained in:
commit
6107a59306
@ -33,6 +33,7 @@ Name | Description | Enabled by default
|
||||
[service](docs/collector.service.md) | Service state metrics | ✓
|
||||
[system](docs/collector.system.md) | System calls | ✓
|
||||
[tcp](docs/collector.tcp.md) | TCP connections |
|
||||
[thermalzone](docs/collector.thermalzone.md) | Thermal information
|
||||
[textfile](docs/collector.textfile.md) | Read prometheus metrics from a text file | ✓
|
||||
[vmware](docs/collector.vmware.md) | Performance counters installed by the Vmware Guest agent |
|
||||
|
||||
|
103
collector/thermalzone.go
Normal file
103
collector/thermalzone.go
Normal file
@ -0,0 +1,103 @@
|
||||
package collector
|
||||
|
||||
import (
|
||||
"github.com/StackExchange/wmi"
|
||||
"github.com/prometheus/client_golang/prometheus"
|
||||
"github.com/prometheus/common/log"
|
||||
)
|
||||
|
||||
func init() {
|
||||
Factories["thermalzone"] = NewThermalZoneCollector
|
||||
}
|
||||
|
||||
// A ThermalZoneCollector is a Prometheus collector for WMI Win32_PerfRawData_Counters_ThermalZoneInformation metrics
|
||||
type ThermalZoneCollector struct {
|
||||
PercentPassiveLimit *prometheus.Desc
|
||||
Temperature *prometheus.Desc
|
||||
ThrottleReasons *prometheus.Desc
|
||||
}
|
||||
|
||||
// NewThermalZoneCollector ...
|
||||
func NewThermalZoneCollector() (Collector, error) {
|
||||
const subsystem = "thermalzone"
|
||||
return &ThermalZoneCollector{
|
||||
Temperature: prometheus.NewDesc(
|
||||
prometheus.BuildFQName(Namespace, subsystem, "temperature_celsius"),
|
||||
"(Temperature)",
|
||||
[]string{
|
||||
"Name",
|
||||
},
|
||||
nil,
|
||||
),
|
||||
PercentPassiveLimit: prometheus.NewDesc(
|
||||
prometheus.BuildFQName(Namespace, subsystem, "percent_passive_limit"),
|
||||
"(PercentPassiveLimit)",
|
||||
[]string{
|
||||
"Name",
|
||||
},
|
||||
nil,
|
||||
),
|
||||
ThrottleReasons: prometheus.NewDesc(
|
||||
prometheus.BuildFQName(Namespace, subsystem, "throttle_reasons"),
|
||||
"(ThrottleReasons)",
|
||||
[]string{
|
||||
"Name",
|
||||
},
|
||||
nil,
|
||||
),
|
||||
}, nil
|
||||
}
|
||||
|
||||
// Collect sends the metric values for each metric
|
||||
// to the provided prometheus Metric channel.
|
||||
func (c *ThermalZoneCollector) Collect(ch chan<- prometheus.Metric) error {
|
||||
if desc, err := c.collect(ch); err != nil {
|
||||
log.Error("failed collecting thermalzone metrics:", desc, err)
|
||||
return err
|
||||
}
|
||||
return nil
|
||||
}
|
||||
|
||||
// Win32_PerfRawData_Counters_ThermalZoneInformation docs:
|
||||
// https://wutils.com/wmi/root/cimv2/win32_perfrawdata_counters_thermalzoneinformation/
|
||||
type Win32_PerfRawData_Counters_ThermalZoneInformation struct {
|
||||
Name string
|
||||
|
||||
HighPrecisionTemperature uint32
|
||||
PercentPassiveLimit uint32
|
||||
ThrottleReasons uint32
|
||||
}
|
||||
|
||||
func (c *ThermalZoneCollector) collect(ch chan<- prometheus.Metric) (*prometheus.Desc, error) {
|
||||
var dst []Win32_PerfRawData_Counters_ThermalZoneInformation
|
||||
q := queryAll(&dst)
|
||||
if err := wmi.Query(q, &dst); err != nil {
|
||||
return nil, err
|
||||
}
|
||||
|
||||
for _, info := range dst {
|
||||
//Divide by 10 and subtract 273.15 to convert decikelvin to celsius
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
c.Temperature,
|
||||
prometheus.GaugeValue,
|
||||
(float64(info.HighPrecisionTemperature)/10.0)-273.15,
|
||||
info.Name,
|
||||
)
|
||||
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
c.PercentPassiveLimit,
|
||||
prometheus.GaugeValue,
|
||||
float64(info.PercentPassiveLimit),
|
||||
info.Name,
|
||||
)
|
||||
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
c.ThrottleReasons,
|
||||
prometheus.GaugeValue,
|
||||
float64(info.ThrottleReasons),
|
||||
info.Name,
|
||||
)
|
||||
}
|
||||
|
||||
return nil, nil
|
||||
}
|
32
docs/collector.thermalzone.md
Normal file
32
docs/collector.thermalzone.md
Normal file
@ -0,0 +1,32 @@
|
||||
# thermalzone collector
|
||||
|
||||
The thermalzone collector exposes metrics about system temps. Note that temperature is given in Kelvin
|
||||
|
||||
|||
|
||||
-|-
|
||||
Metric name prefix | `thermalzone`
|
||||
Classes | [`Win32_PerfRawData_Counters_ThermalZoneInformation`](https://wutils.com/wmi/root/cimv2/win32_perfrawdata_counters_thermalzoneinformation/#temperature_properties)
|
||||
Enabled by default? | No
|
||||
|
||||
## Flags
|
||||
|
||||
None
|
||||
|
||||
## Metrics
|
||||
|
||||
Name | Description | Type | Labels
|
||||
-----|-------------|------|-------
|
||||
`wmi_thermalzone_percent_passive_limit` | % Passive Limit is the current limit this thermal zone is placing on the devices it controls. A limit of 100% indicates the devices are unconstrained. A limit of 0% indicates the devices are fully constrained. | gauge | None
|
||||
`wmi_thermalzone_temperature_celsius ` | Temperature of the thermal zone, in degrees Celsius. | gauge | None
|
||||
`wmi_thermalzone_throttle_reasons ` | Throttle Reasons indicate reasons why the thermal zone is limiting performance of the devices it controls. 0x0 – The zone is not throttled. 0x1 – The zone is throttled for thermal reasons. 0x2 – The zone is throttled to limit electrical current. | gauge | None
|
||||
|
||||
[`Throttle reasons` source](https://docs.microsoft.com/en-us/windows-hardware/design/device-experiences/examples--requirements-and-diagnostics)
|
||||
|
||||
### Example metric
|
||||
_This collector does not yet have explained examples, we would appreciate your help adding them!_
|
||||
|
||||
## Useful queries
|
||||
_This collector does not yet have any useful queries added, we would appreciate your help adding them!_
|
||||
|
||||
## Alerting examples
|
||||
_This collector does not yet have alerting examples, we would appreciate your help adding them!_
|
Loading…
Reference in New Issue