bcm63xx: use the generic nand upgrade on Sercomm devices
The Sercomm devices don't need the jffs2 cleanmarkers for the kernel partition. With the stock firmware they are only added when the bootloader partition is upgraded. Furthermore, on the Sercomm H500-s, the specific cfe_jffs2_upgrade_tar function causes OOB corruption. As a result of this, combined with the nature of the mtdsplit driver, the upgrade procedure ends in a bricked device. Use the generic nand_do_upgrade provided by the OpenWrt common functions. Signed-off-by: Daniel González Cabanelas <dgcbueu@gmail.com>
This commit is contained in:
parent
636b62e8e2
commit
e3eaf52ba3
|
@ -70,12 +70,15 @@ platform_do_upgrade() {
|
|||
comtrend,vg-8050|\
|
||||
comtrend,vr-3032u|\
|
||||
huawei,hg253s-v2|\
|
||||
netgear,dgnd3700-v2|\
|
||||
netgear,dgnd3700-v2)
|
||||
REQUIRE_IMAGE_METADATA=1
|
||||
cfe_jffs2_upgrade_tar "$1"
|
||||
;;
|
||||
sercomm,ad1018|\
|
||||
sercomm,h500-s-lowi|\
|
||||
sercomm,h500-s-vfes)
|
||||
REQUIRE_IMAGE_METADATA=1
|
||||
cfe_jffs2_upgrade_tar "$1"
|
||||
nand_do_upgrade "$1"
|
||||
;;
|
||||
*)
|
||||
default_do_upgrade "$1"
|
||||
|
|
Loading…
Reference in New Issue