ramips: increase SPI frequency for MT7620 Archer

Increase the SPI frequency for the MT7620 based TP-Link Archer
series to 30MHz.

TP-Link uses different SPI flash chips for the same board
revision, so be conservative to not break boards with a
different chip. 30MHz should be well supported by all chips.

Tested on Archer C2 v1 (GD25Q64B) and Archer C20i (W25Q64FV).

Archer C20i (before)
====================
root@OpenWrt:~# time dd if=/dev/mtd1 of=/tmp/test.bin bs=64k
122+0 records in
122+0 records out
real	0m 15.30s
user	0m 0.00s
sys	0m 15.29s

Archer C20i (after)
===================
root@OpenWrt:~# time dd if=/dev/mtd1 of=/tmp/test.bin bs=64k
122+0 records in
122+0 records out
real	0m 5.99s
user	0m 0.00s
sys	0m 5.98s

Signed-off-by: David Bauer <mail@david-bauer.net>
Acked-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
This commit is contained in:
David Bauer 2020-07-21 20:11:28 +02:00
parent 9a9cdc65c4
commit 4cd5ce5a7f
3 changed files with 3 additions and 3 deletions

View File

@ -82,7 +82,7 @@
flash@0 {
compatible = "jedec,spi-nor";
reg = <0>;
spi-max-frequency = <10000000>;
spi-max-frequency = <30000000>;
partitions {
compatible = "fixed-partitions";

View File

@ -121,7 +121,7 @@
flash@0 {
compatible = "jedec,spi-nor";
reg = <0>;
spi-max-frequency = <10000000>;
spi-max-frequency = <30000000>;
partitions {
compatible = "fixed-partitions";

View File

@ -43,7 +43,7 @@
flash@0 {
compatible = "jedec,spi-nor";
reg = <0>;
spi-max-frequency = <10000000>;
spi-max-frequency = <30000000>;
partitions {
compatible = "fixed-partitions";