mvebu: split interface configuration for clearfog pro and base

Handle both variants separately. This removes the need for calling
swconfig to detect the switch, and simplifies future changes.

Signed-off-by: Josua Mayer <josua.mayer@jm0.eu>
This commit is contained in:
Josua Mayer 2019-12-26 15:25:04 +01:00 committed by Adrian Schmutzler
parent 5e5e92b7c3
commit 12795ec9f1
1 changed files with 10 additions and 6 deletions

View File

@ -52,17 +52,21 @@ marvell,axp-gp)
methode,udpu)
ucidef_set_interfaces_lan_wan "eth1" "eth0"
;;
solidrun,clearfog*a1)
solidrun,clearfog-a1|solidrun,clearfog-pro-a1)
# eth0 is standalone ethernet
# eth1 is switch (-pro) or standalone ethernet (-base)
# eth1 is switch
# eth2 is SFP
ucidef_set_interfaces_lan_wan "eth1" "eth0 eth2"
# if switch exists (clearfog-pro)
# switch port 5 is connected to eth1
swconfig list 2>&1 | grep -q switch0 && \
ucidef_add_switch "switch0" \
"0:lan:5" "1:lan:4" "2:lan:3" "3:lan:2" "4:lan:1" "5u@eth1" "6:lan:6"
ucidef_add_switch "switch0" \
"0:lan:5" "1:lan:4" "2:lan:3" "3:lan:2" "4:lan:1" "5u@eth1" "6:lan:6"
;;
solidrun,clearfog-base-a1)
# eth0 is standalone ethernet
# eth1 is standalone ethernet
# eth2 is SFP
ucidef_set_interfaces_lan_wan "eth1" "eth0 eth2"
;;
*)
ucidef_set_interface_lan "eth0"