collector/hwmon_linux: handle temperature sensor file which doesn't have item suffix (#1123)
In some cases the file might be called "temp" instead of the usual format "temp<index>_<item>" as described in the kernel docs: https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface In this case, treat this as an _input file containing the current temperature reading. Fixes #1122 Signed-off-by: Paul Gier <pgier@redhat.com>
This commit is contained in:
parent
38163f234f
commit
988f049040
|
@ -274,6 +274,9 @@ func (c *hwMonCollector) updateHwmon(ch chan<- prometheus.Metric, dir string) er
|
|||
continue
|
||||
}
|
||||
if sensorType == "temp" && element != "type" {
|
||||
if element == "" {
|
||||
element = "input"
|
||||
}
|
||||
desc := prometheus.NewDesc(name+"_celsius", "Hardware monitor for temperature ("+element+")", hwmonLabelDesc, nil)
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
||||
|
|
Loading…
Reference in New Issue