Misc doc fixes for README and example configs
This commit is contained in:
parent
35a6530c50
commit
2ae0db3934
34
README.md
34
README.md
|
@ -64,8 +64,10 @@ Make sure you have the following tools from the
|
|||
|
||||
- `ipmimonitoring`/`ipmi-sensors`
|
||||
- `ipmi-dcmi`
|
||||
- `ipmi-raw`
|
||||
- `bmc-info`
|
||||
- `ipmi-sel`
|
||||
- `ipmi-chassis`
|
||||
|
||||
### Running as unprivileged user
|
||||
|
||||
|
@ -77,6 +79,7 @@ FreeIPMI tools as root, you can do the following:
|
|||
ipmi-exporter ALL = NOPASSWD: /usr/sbin/ipmimonitoring,\
|
||||
/usr/sbin/ipmi-sensors,\
|
||||
/usr/sbin/ipmi-dcmi,\
|
||||
/usr/sbin/ipmi-raw,\
|
||||
/usr/sbin/bmc-info,\
|
||||
/usr/sbin/ipmi-chassis,\
|
||||
/usr/sbin/ipmi-sel
|
||||
|
@ -91,8 +94,10 @@ FreeIPMI tools as root, you can do the following:
|
|||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmimonitoring
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmi-sensors
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmi-dcmi
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmi-raw
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/bmc-info
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmi-chassis
|
||||
ln -s /home/ipmi-exporter/[script name] /home/ipmi-exporter/ipmi-raw
|
||||
````
|
||||
4. Execute ipmi-exporter with the option `--freeipmi.path=/home/ipmi-exporter`
|
||||
|
||||
|
@ -267,8 +272,14 @@ These metrics provide data about the scrape itself:
|
|||
will not be available
|
||||
- `dcmi`: collects DCMI data, currently only power consumption. If it fails,
|
||||
power consumption metrics (see below) will not be available
|
||||
- `bmc`: collects BMC details. If if fails, BMC info metrics (see below)
|
||||
- `bmc`: collects BMC details. If it fails, BMC info metrics (see below)
|
||||
will not be available
|
||||
- `chassis`: collects the current chassis power state (on/off). If it fails,
|
||||
the chassis power state metric (see below) will not be available
|
||||
- `sel`: collects system event log (SEL) details. If it fails, SEL metrics
|
||||
(see below) will not be available
|
||||
- `sm-lan-mode`: collects the "LAN mode" setting in the current BMC config.
|
||||
If it fails, the LAN mode metric (see below) will not be available
|
||||
- `ipmi_scrape_duration_seconds` is the amount of time it took to retrieve the
|
||||
data
|
||||
|
||||
|
@ -301,7 +312,7 @@ might suggest that they measure the same thing. This metric has no labels.
|
|||
|
||||
### System event log (SEL) info
|
||||
|
||||
These metrics is only provided if the `sel` collector is enabled (it isn't by
|
||||
These metrics are only provided if the `sel` collector is enabled (it isn't by
|
||||
default).
|
||||
|
||||
The metric `ipmi_sel_entries_count` contains the current number of entries in
|
||||
|
@ -311,9 +322,26 @@ no labels.
|
|||
The metric `ipmi_sel_free_space_bytes` contains the current number of free
|
||||
space for new SEL entries, in bytes. This metric has no labels.
|
||||
|
||||
### Supermicro LAN mode setting
|
||||
|
||||
This metric is only provided if the `sm-lan-mode` collector is enabled (it
|
||||
isn't by default).
|
||||
|
||||
**NOTE:** This is a vendor-specific collector, it will only work on Supermicro
|
||||
hardware, possibly even only on _some_ Supermicro systems.
|
||||
|
||||
**NOTE:** Retrieving this setting requires setting `privilege: "admin"` in the
|
||||
config.
|
||||
|
||||
See e.g. https://www.supermicro.com/support/faqs/faq.cfm?faq=28159
|
||||
|
||||
The metric `ipmi_config_lan_mode` contains the value for the current "LAN mode"
|
||||
setting (see link above): `0` for "dedicated", `1` for "shared", and `2` for
|
||||
"failover".
|
||||
|
||||
### Sensors
|
||||
|
||||
These metric are only provided if the `ipmi` collector is enabled.
|
||||
These metrics are only provided if the `ipmi` collector is enabled.
|
||||
|
||||
IPMI sensors in general have one or two distinct pieces of information that are
|
||||
of interest: a value and/or a state. The exporter always exports both, even if
|
||||
|
|
|
@ -4,7 +4,7 @@
|
|||
# In most cases, this should work without using a config file at all.
|
||||
modules:
|
||||
default:
|
||||
# Available collectors are bmc, ipmi, chassis, dcmi, and sel
|
||||
# Available collectors are bmc, ipmi, chassis, dcmi, sel, and sm-lan-mode
|
||||
collectors:
|
||||
- bmc
|
||||
- ipmi
|
||||
|
|
|
@ -21,7 +21,7 @@ modules:
|
|||
# to (session-timeout * #-of-collectors) milliseconds, so set the scrape
|
||||
# timeout in Prometheus accordingly.
|
||||
timeout: 10000
|
||||
# Available collectors are bmc, ipmi, chassis, dcmi, and sel
|
||||
# Available collectors are bmc, ipmi, chassis, dcmi, sel, and sm-lan-mode
|
||||
# If _not_ specified, bmc, ipmi, chassis, and dcmi are used
|
||||
collectors:
|
||||
- bmc
|
||||
|
|
Loading…