Merge pull request #145 from petshopjke1337/add_more_faults_metric
Add chassis cooling fault and drive fault metrics
This commit is contained in:
commit
22285c9300
|
@ -31,6 +31,18 @@ var (
|
|||
[]string{},
|
||||
nil,
|
||||
)
|
||||
chassisDriveFaultDesc = prometheus.NewDesc(
|
||||
prometheus.BuildFQName(namespace, "chassis", "drive_fault_state"),
|
||||
"Current drive fault state (1=false, 0=true).",
|
||||
[]string{},
|
||||
nil,
|
||||
)
|
||||
chassisCoolingFaultDesc = prometheus.NewDesc(
|
||||
prometheus.BuildFQName(namespace, "chassis", "cooling_fault_state"),
|
||||
"Current Cooling/fan fault state (1=false, 0=true).",
|
||||
[]string{},
|
||||
nil,
|
||||
)
|
||||
)
|
||||
|
||||
type ChassisCollector struct{}
|
||||
|
@ -49,6 +61,8 @@ func (c ChassisCollector) Args() []string {
|
|||
|
||||
func (c ChassisCollector) Collect(result freeipmi.Result, ch chan<- prometheus.Metric, target ipmiTarget) (int, error) {
|
||||
currentChassisPowerState, err := freeipmi.GetChassisPowerState(result)
|
||||
currentChassisDriveFault, err := freeipmi.GetChassisDriveFault(result)
|
||||
currentChassisCoolingFault, err := freeipmi.GetChassisCoolingFault(result)
|
||||
if err != nil {
|
||||
level.Error(logger).Log("msg", "Failed to collect chassis data", "target", targetName(target.host), "error", err)
|
||||
return 0, err
|
||||
|
@ -58,5 +72,15 @@ func (c ChassisCollector) Collect(result freeipmi.Result, ch chan<- prometheus.M
|
|||
prometheus.GaugeValue,
|
||||
currentChassisPowerState,
|
||||
)
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
chassisDriveFaultDesc,
|
||||
prometheus.GaugeValue,
|
||||
currentChassisDriveFault,
|
||||
)
|
||||
ch <- prometheus.MustNewConstMetric(
|
||||
chassisCoolingFaultDesc,
|
||||
prometheus.GaugeValue,
|
||||
currentChassisCoolingFault,
|
||||
)
|
||||
return 1, nil
|
||||
}
|
||||
|
|
|
@ -35,6 +35,8 @@ import (
|
|||
var (
|
||||
ipmiDCMICurrentPowerRegex = regexp.MustCompile(`^Current Power\s*:\s*(?P<value>[0-9.]*)\s*Watts.*`)
|
||||
ipmiChassisPowerRegex = regexp.MustCompile(`^System Power\s*:\s(?P<value>.*)`)
|
||||
ipmiChassisDriveFaultRegex = regexp.MustCompile(`^Drive Fault\s*:\s(?P<value>.*)`)
|
||||
ipmiChassisCoolingFaultRegex = regexp.MustCompile(`^Cooling/fan fault\s*:\s(?P<value>.*)`)
|
||||
ipmiSELEntriesRegex = regexp.MustCompile(`^Number of log entries\s*:\s(?P<value>[0-9.]*)`)
|
||||
ipmiSELFreeSpaceRegex = regexp.MustCompile(`^Free space remaining\s*:\s(?P<value>[0-9.]*)\s*bytes.*`)
|
||||
bmcInfoFirmwareRevisionRegex = regexp.MustCompile(`^Firmware Revision\s*:\s*(?P<value>[0-9.]*).*`)
|
||||
|
@ -219,6 +221,34 @@ func GetChassisPowerState(ipmiOutput Result) (float64, error) {
|
|||
return 0, err
|
||||
}
|
||||
|
||||
func GetChassisDriveFault(ipmiOutput Result) (float64, error) {
|
||||
if ipmiOutput.err != nil {
|
||||
return -1, fmt.Errorf("%s: %s", ipmiOutput.err, ipmiOutput.output)
|
||||
}
|
||||
value, err := getValue(ipmiOutput.output, ipmiChassisDriveFaultRegex)
|
||||
if err != nil {
|
||||
return -1, err
|
||||
}
|
||||
if value == "false" {
|
||||
return 1, err
|
||||
}
|
||||
return 0, err
|
||||
}
|
||||
|
||||
func GetChassisCoolingFault(ipmiOutput Result) (float64, error) {
|
||||
if ipmiOutput.err != nil {
|
||||
return -1, fmt.Errorf("%s: %s", ipmiOutput.err, ipmiOutput.output)
|
||||
}
|
||||
value, err := getValue(ipmiOutput.output, ipmiChassisCoolingFaultRegex)
|
||||
if err != nil {
|
||||
return -1, err
|
||||
}
|
||||
if value == "false" {
|
||||
return 1, err
|
||||
}
|
||||
return 0, err
|
||||
}
|
||||
|
||||
func GetBMCInfoFirmwareRevision(ipmiOutput Result) (string, error) {
|
||||
// Workaround for an issue described here: https://github.com/prometheus-community/ipmi_exporter/issues/57
|
||||
// The command may fail, but produce usable output (minus the system firmware revision).
|
||||
|
|
Loading…