psymodel: dont apply lowpass filters with a cutoff close to the nyquist

The IIR filter numerically diverges in such cases, this could easily be
fixed but would make the filter slower on some platforms

Fixes Ticket2246

Signed-off-by: Michael Niedermayer <michaelni@gmx.at>
This commit is contained in:
Michael Niedermayer 2013-03-07 19:28:30 +01:00
parent cada996528
commit fee5da6b0a

View File

@ -106,7 +106,7 @@ av_cold struct FFPsyPreprocessContext* ff_psy_preprocess_init(AVCodecContext *av
if (!cutoff_coeff && avctx->codec_id == AV_CODEC_ID_AAC)
cutoff_coeff = 2.0 * AAC_CUTOFF(avctx) / avctx->sample_rate;
if (cutoff_coeff)
if (cutoff_coeff && cutoff_coeff < 0.98)
ctx->fcoeffs = ff_iir_filter_init_coeffs(avctx, FF_FILTER_TYPE_BUTTERWORTH,
FF_FILTER_MODE_LOWPASS, FILT_ORDER,
cutoff_coeff, 0.0, 0.0);