.. _ceph-volume-zfs-api:
|
|
|
|
ZFS
|
|
===
|
|
The backend of ``ceph-volume zfs`` is ZFS, it relies heavily on the usage of
|
|
tags, which is a way for ZFS to allow extending its volume metadata. These
|
|
values can later be queried against devices and it is how they get discovered
|
|
later.
|
|
|
|
Currently this interface is only usable when running on FreeBSD.
|
|
|
|
.. warning:: These APIs are not meant to be public, but are documented so that
|
|
it is clear what the tool is doing behind the scenes. Do not alter
|
|
any of these values.
|
|
|
|
|
|
.. _ceph-volume-zfs-tag-api:
|
|
|
|
Tag API
|
|
-------
|
|
The process of identifying filesystems, volumes and pools as part of Ceph relies
|
|
on applying tags on all volumes. It follows a naming convention for the
|
|
namespace that looks like::
|
|
|
|
ceph.<tag name>=<tag value>
|
|
|
|
All tags are prefixed by the ``ceph`` keyword to claim ownership of that
|
|
namespace and make it easily identifiable. This is how the OSD ID would be used
|
|
in the context of zfs tags::
|
|
|
|
ceph.osd_id=0
|
|
|
|
Tags on filesystems are stored as property.
|
|
Tags on a zpool are stored in the comment property as a concatenated list
|
|
separated by ``;``
|
|
|
|
.. _ceph-volume-zfs-tags:
|
|
|
|
Metadata
|
|
--------
|
|
The following describes all the metadata from Ceph OSDs that is stored on a
|
|
ZFS filesystem, volume, pool:
|
|
|
|
|
|
``type``
|
|
--------
|
|
Describes if the device is an OSD or Journal, with the ability to expand to
|
|
other types when supported
|
|
|
|
Example::
|
|
|
|
ceph.type=osd
|
|
|
|
|
|
``cluster_fsid``
|
|
----------------
|
|
Example::
|
|
|
|
ceph.cluster_fsid=7146B649-AE00-4157-9F5D-1DBFF1D52C26
|
|
|
|
|
|
``data_device``
|
|
---------------
|
|
Example::
|
|
|
|
ceph.data_device=/dev/ceph/data-0
|
|
|
|
|
|
``data_uuid``
|
|
-------------
|
|
Example::
|
|
|
|
ceph.data_uuid=B76418EB-0024-401C-8955-AE6919D45CC3
|
|
|
|
|
|
``journal_device``
|
|
------------------
|
|
Example::
|
|
|
|
ceph.journal_device=/dev/ceph/journal-0
|
|
|
|
|
|
``journal_uuid``
|
|
----------------
|
|
Example::
|
|
|
|
ceph.journal_uuid=2070E121-C544-4F40-9571-0B7F35C6CB2B
|
|
|
|
|
|
``osd_fsid``
|
|
------------
|
|
Example::
|
|
|
|
ceph.osd_fsid=88ab9018-f84b-4d62-90b4-ce7c076728ff
|
|
|
|
|
|
``osd_id``
|
|
----------
|
|
Example::
|
|
|
|
ceph.osd_id=1
|
|
|
|
|
|
``block_device``
|
|
----------------
|
|
Just used on :term:`bluestore` backends. Captures the path to the logical
|
|
volume path.
|
|
|
|
Example::
|
|
|
|
ceph.block_device=/dev/gpt/block-0
|
|
|
|
|
|
``block_uuid``
|
|
--------------
|
|
Just used on :term:`bluestore` backends. Captures either the logical volume UUID or
|
|
the partition UUID.
|
|
|
|
Example::
|
|
|
|
ceph.block_uuid=E5F041BB-AAD4-48A8-B3BF-31F7AFD7D73E
|
|
|
|
|
|
``db_device``
|
|
-------------
|
|
Just used on :term:`bluestore` backends. Captures the path to the logical
|
|
volume path.
|
|
|
|
Example::
|
|
|
|
ceph.db_device=/dev/gpt/db-0
|
|
|
|
|
|
``db_uuid``
|
|
-----------
|
|
Just used on :term:`bluestore` backends. Captures either the logical volume UUID or
|
|
the partition UUID.
|
|
|
|
Example::
|
|
|
|
ceph.db_uuid=F9D02CF1-31AB-4910-90A3-6A6302375525
|
|
|
|
|
|
``wal_device``
|
|
--------------
|
|
Just used on :term:`bluestore` backends. Captures the path to the logical
|
|
volume path.
|
|
|
|
Example::
|
|
|
|
ceph.wal_device=/dev/gpt/wal-0
|
|
|
|
|
|
``wal_uuid``
|
|
------------
|
|
Just used on :term:`bluestore` backends. Captures either the logical volume UUID or
|
|
the partition UUID.
|
|
|
|
Example::
|
|
|
|
ceph.wal_uuid=A58D1C68-0D6E-4CB3-8E99-B261AD47CC39
|
|
|
|
|
|
``compression``
|
|
---------------
|
|
A compression-enabled device can always be set using the native zfs settings on
|
|
a volume or filesystem. This will/can be activated during creation of the volume
|
|
of filesystem.
|
|
When activated by ``ceph-volume zfs`` this tag will be created.
|
|
Compression manually set AFTER ``ceph-volume`` will go unnoticed, unless this
|
|
tag is also manually set.
|
|
|
|
Example for an enabled compression device::
|
|
|
|
ceph.vdo=1
|