mirror of
https://github.com/ceph/ceph
synced 2024-12-14 23:46:28 +00:00
b0abab17e3
Signed-off-by: Jason Dillaman <dillaman@redhat.com>
37 lines
1.4 KiB
ReStructuredText
37 lines
1.4 KiB
ReStructuredText
----------------------------------
|
||
The iSCSI Initiator for VMware ESX
|
||
----------------------------------
|
||
|
||
**Prerequisite:**
|
||
|
||
- VMware ESX 6.0 or later
|
||
|
||
**iSCSI Discovery and Multipath Device Setup:**
|
||
|
||
#. From vSphere, open the Storage Adapters, on the Configuration tab. Right click
|
||
on the iSCSI Software Adapter and select Properties.
|
||
|
||
#. In the General tab click the "Advanced" button and in the "Advanced Settings"
|
||
set RecoveryTimeout to 25.
|
||
|
||
#. If CHAP was setup on the iSCSI gateway, in the General tab click the "CHAP…"
|
||
button. If CHAP is not being used, skip to step 4.
|
||
|
||
#. On the CHAP Credentials windows, select “Do not use CHAP unless required by target”,
|
||
and enter the "Name" and "Secret" values used on the initial setup for the iSCSI
|
||
gateway, then click on the "OK" button.
|
||
|
||
#. On the Dynamic Discovery tab, click the "Add…" button, and enter the IP address
|
||
and port of one of the iSCSI target portals. Click on the "OK" button.
|
||
|
||
#. Close the iSCSI Initiator Properties window. A prompt will ask to rescan the
|
||
iSCSI software adapter. Select Yes.
|
||
|
||
#. In the Details pane, the LUN on the iSCSI target will be displayed. Right click
|
||
on a device and select "Manage Paths".
|
||
|
||
#. On the Manage Paths window, select “Most Recently Used (VMware)” for the policy
|
||
path selection. Close and repeat for the other disks.
|
||
|
||