This commit rewrites the entire "Remove an OSD" section of the "OSD Service" chapter of the cephadm book. I got carried away and didn't break this one into four smaller PRs, and I'm sorry in advance to whomever ends up reviewing this. I'll break "Advanced OSD Service Specifications", the next section in the queue, into multiple sections. Signed-off-by: Zac Dover <zac.dover@gmail.com>
808 lines
20 KiB
ReStructuredText
808 lines
20 KiB
ReStructuredText
***********
|
|
OSD Service
|
|
***********
|
|
.. _device management: ../rados/operations/devices
|
|
.. _libstoragemgmt: https://github.com/libstorage/libstoragemgmt
|
|
|
|
List Devices
|
|
============
|
|
|
|
``ceph-volume`` scans each cluster in the host from time to time in order
|
|
to determine which devices are present and whether they are eligible to be
|
|
used as OSDs.
|
|
|
|
To print a list of devices discovered by ``cephadm``, run this command:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch device ls [--hostname=...] [--wide] [--refresh]
|
|
|
|
Example
|
|
::
|
|
|
|
Hostname Path Type Serial Size Health Ident Fault Available
|
|
srv-01 /dev/sdb hdd 15P0A0YFFRD6 300G Unknown N/A N/A No
|
|
srv-01 /dev/sdc hdd 15R0A08WFRD6 300G Unknown N/A N/A No
|
|
srv-01 /dev/sdd hdd 15R0A07DFRD6 300G Unknown N/A N/A No
|
|
srv-01 /dev/sde hdd 15P0A0QDFRD6 300G Unknown N/A N/A No
|
|
srv-02 /dev/sdb hdd 15R0A033FRD6 300G Unknown N/A N/A No
|
|
srv-02 /dev/sdc hdd 15R0A05XFRD6 300G Unknown N/A N/A No
|
|
srv-02 /dev/sde hdd 15R0A0ANFRD6 300G Unknown N/A N/A No
|
|
srv-02 /dev/sdf hdd 15R0A06EFRD6 300G Unknown N/A N/A No
|
|
srv-03 /dev/sdb hdd 15R0A0OGFRD6 300G Unknown N/A N/A No
|
|
srv-03 /dev/sdc hdd 15R0A0P7FRD6 300G Unknown N/A N/A No
|
|
srv-03 /dev/sdd hdd 15R0A0O7FRD6 300G Unknown N/A N/A No
|
|
|
|
Using the ``--wide`` option provides all details relating to the device,
|
|
including any reasons that the device might not be eligible for use as an OSD.
|
|
|
|
In the above example you can see fields named "Health", "Ident", and "Fault".
|
|
This information is provided by integration with `libstoragemgmt`_. By default,
|
|
this integration is disabled (because `libstoragemgmt`_ may not be 100%
|
|
compatible with your hardware). To make ``cephadm`` include these fields,
|
|
enable cephadm's "enhanced device scan" option as follows;
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph config set mgr mgr/cephadm/device_enhanced_scan true
|
|
|
|
.. warning::
|
|
Although the libstoragemgmt library performs standard SCSI inquiry calls,
|
|
there is no guarantee that your firmware fully implements these standards.
|
|
This can lead to erratic behaviour and even bus resets on some older
|
|
hardware. It is therefore recommended that, before enabling this feature,
|
|
you test your hardware's compatibility with libstoragemgmt first to avoid
|
|
unplanned interruptions to services.
|
|
|
|
There are a number of ways to test compatibility, but the simplest may be
|
|
to use the cephadm shell to call libstoragemgmt directly - ``cephadm shell
|
|
lsmcli ldl``. If your hardware is supported you should see something like
|
|
this:
|
|
|
|
::
|
|
|
|
Path | SCSI VPD 0x83 | Link Type | Serial Number | Health Status
|
|
----------------------------------------------------------------------------
|
|
/dev/sda | 50000396082ba631 | SAS | 15P0A0R0FRD6 | Good
|
|
/dev/sdb | 50000396082bbbf9 | SAS | 15P0A0YFFRD6 | Good
|
|
|
|
|
|
After you have enabled libstoragemgmt support, the output will look something
|
|
like this:
|
|
|
|
::
|
|
|
|
# ceph orch device ls
|
|
Hostname Path Type Serial Size Health Ident Fault Available
|
|
srv-01 /dev/sdb hdd 15P0A0YFFRD6 300G Good Off Off No
|
|
srv-01 /dev/sdc hdd 15R0A08WFRD6 300G Good Off Off No
|
|
:
|
|
|
|
In this example, libstoragemgmt has confirmed the health of the drives and the ability to
|
|
interact with the Identification and Fault LEDs on the drive enclosures. For further
|
|
information about interacting with these LEDs, refer to `device management`_.
|
|
|
|
.. note::
|
|
The current release of `libstoragemgmt`_ (1.8.8) supports SCSI, SAS, and SATA based
|
|
local disks only. There is no official support for NVMe devices (PCIe)
|
|
|
|
.. _cephadm-deploy-osds:
|
|
|
|
Deploy OSDs
|
|
===========
|
|
|
|
Listing Storage Devices
|
|
-----------------------
|
|
|
|
In order to deploy an OSD, there must be a storage device that is *available* on
|
|
which the OSD will be deployed.
|
|
|
|
Run this command to display an inventory of storage devices on all cluster hosts:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch device ls
|
|
|
|
A storage device is considered *available* if all of the following
|
|
conditions are met:
|
|
|
|
* The device must have no partitions.
|
|
* The device must not have any LVM state.
|
|
* The device must not be mounted.
|
|
* The device must not contain a file system.
|
|
* The device must not contain a Ceph BlueStore OSD.
|
|
* The device must be larger than 5 GB.
|
|
|
|
Ceph will not provision an OSD on a device that is not available.
|
|
|
|
Creating New OSDs
|
|
-----------------
|
|
|
|
There are a few ways to create new OSDs:
|
|
|
|
* Tell Ceph to consume any available and unused storage device:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch apply osd --all-available-devices
|
|
|
|
* Create an OSD from a specific device on a specific host:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch daemon add osd *<host>*:*<device-path>*
|
|
|
|
For example:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch daemon add osd host1:/dev/sdb
|
|
|
|
* You can use :ref:`drivegroups` to categorize device(s) based on their
|
|
properties. This might be useful in forming a clearer picture of which
|
|
devices are available to consume. Properties include device type (SSD or
|
|
HDD), device model names, size, and the hosts on which the devices exist:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch apply -i spec.yml
|
|
|
|
Dry Run
|
|
-------
|
|
|
|
The ``--dry-run`` flag causes the orchestrator to present a preview of what
|
|
will happen without actually creating the OSDs.
|
|
|
|
For example:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch apply osd --all-available-devices --dry-run
|
|
|
|
::
|
|
|
|
NAME HOST DATA DB WAL
|
|
all-available-devices node1 /dev/vdb - -
|
|
all-available-devices node2 /dev/vdc - -
|
|
all-available-devices node3 /dev/vdd - -
|
|
|
|
.. _cephadm-osd-declarative:
|
|
|
|
Declarative State
|
|
-----------------
|
|
|
|
Note that the effect of ``ceph orch apply`` is persistent; that is, drives which are added to the system
|
|
or become available (say, by zapping) after the command is complete will be automatically found and added to the cluster.
|
|
|
|
That is, after using::
|
|
|
|
ceph orch apply osd --all-available-devices
|
|
|
|
* If you add new disks to the cluster they will automatically be used to create new OSDs.
|
|
* A new OSD will be created automatically if you remove an OSD and clean the LVM physical volume.
|
|
|
|
If you want to avoid this behavior (disable automatic creation of OSD on available devices), use the ``unmanaged`` parameter:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch apply osd --all-available-devices --unmanaged=true
|
|
|
|
* For cephadm, see also :ref:`cephadm-spec-unmanaged`.
|
|
|
|
|
|
Remove an OSD
|
|
=============
|
|
|
|
Removing an OSD from a cluster involves two steps:
|
|
|
|
#. evacuating all placement groups (PGs) from the cluster
|
|
#. removing the PG-free OSD from the cluster
|
|
|
|
The following command performs these two steps:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm <osd_id(s)> [--replace] [--force]
|
|
|
|
Example:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm 0
|
|
|
|
Expected output::
|
|
|
|
Scheduled OSD(s) for removal
|
|
|
|
OSDs that are not safe to destroy will be rejected.
|
|
|
|
Monitoring OSD State
|
|
--------------------
|
|
|
|
You can query the state of OSD operation with the following command:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm status
|
|
|
|
Expected output::
|
|
|
|
OSD_ID HOST STATE PG_COUNT REPLACE FORCE STARTED_AT
|
|
2 cephadm-dev done, waiting for purge 0 True False 2020-07-17 13:01:43.147684
|
|
3 cephadm-dev draining 17 False True 2020-07-17 13:01:45.162158
|
|
4 cephadm-dev started 42 False True 2020-07-17 13:01:45.162158
|
|
|
|
|
|
When no PGs are left on the OSD, it will be decommissioned and removed from the cluster.
|
|
|
|
.. note::
|
|
After removing an OSD, if you wipe the LVM physical volume in the device used by the removed OSD, a new OSD will be created.
|
|
For more information on this, read about the ``unmanaged`` parameter in :ref:`cephadm-osd-declarative`.
|
|
|
|
Stopping OSD Removal
|
|
--------------------
|
|
|
|
It is possible to stop queued OSD removals by using the following command:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm stop <svc_id(s)>
|
|
|
|
Example:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm stop 4
|
|
|
|
Expected output::
|
|
|
|
Stopped OSD(s) removal
|
|
|
|
This resets the initial state of the OSD and takes it off the removal queue.
|
|
|
|
|
|
Replacing an OSD
|
|
----------------
|
|
|
|
.. prompt:: bash #
|
|
|
|
orch osd rm <svc_id(s)> --replace [--force]
|
|
|
|
Example:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch osd rm 4 --replace
|
|
|
|
Expected output::
|
|
|
|
Scheduled OSD(s) for replacement
|
|
|
|
This follows the same procedure as the procedure in the "Remove OSD" section, with
|
|
one exception: the OSD is not permanently removed from the CRUSH hierarchy, but is
|
|
instead assigned a 'destroyed' flag.
|
|
|
|
**Preserving the OSD ID**
|
|
|
|
The 'destroyed' flag is used to determine which OSD ids will be reused in the
|
|
next OSD deployment.
|
|
|
|
If you use OSDSpecs for OSD deployment, your newly added disks will be assigned
|
|
the OSD ids of their replaced counterparts. This assumes that the new disks
|
|
still match the OSDSpecs.
|
|
|
|
Use the ``--dry-run`` flag to make certain that the ``ceph orch apply osd``
|
|
command does what you want it to. The ``--dry-run`` flag shows you what the
|
|
outcome of the command will be without making the changes you specify. When
|
|
you are satisfied that the command will do what you want, run the command
|
|
without the ``--dry-run`` flag.
|
|
|
|
.. tip::
|
|
|
|
The name of your OSDSpec can be retrieved with the command ``ceph orch ls``
|
|
|
|
Alternatively, you can use your OSDSpec file:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch apply osd -i <osd_spec_file> --dry-run
|
|
|
|
Expected output::
|
|
|
|
NAME HOST DATA DB WAL
|
|
<name_of_osd_spec> node1 /dev/vdb - -
|
|
|
|
|
|
When this output reflects your intention, omit the ``--dry-run`` flag to
|
|
execute the deployment.
|
|
|
|
|
|
Erasing Devices (Zapping Devices)
|
|
---------------------------------
|
|
|
|
Erase (zap) a device so that it can be reused. ``zap`` calls ``ceph-volume
|
|
zap`` on the remote host.
|
|
|
|
.. prompt:: bash #
|
|
|
|
orch device zap <hostname> <path>
|
|
|
|
Example command:
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph orch device zap my_hostname /dev/sdx
|
|
|
|
.. note::
|
|
If the unmanaged flag is unset, cephadm automatically deploys drives that
|
|
match the DriveGroup in your OSDSpec. For example, if you use the
|
|
``all-available-devices`` option when creating OSDs, when you ``zap`` a
|
|
device the cephadm orchestrator automatically creates a new OSD in the
|
|
device. To disable this behavior, see :ref:`cephadm-osd-declarative`.
|
|
|
|
|
|
.. _drivegroups:
|
|
|
|
Advanced OSD Service Specifications
|
|
===================================
|
|
|
|
:ref:`orchestrator-cli-service-spec` of type ``osd`` are a way to describe a cluster layout using the properties of disks.
|
|
It gives the user an abstract way tell ceph which disks should turn into an OSD
|
|
with which configuration without knowing the specifics of device names and paths.
|
|
|
|
Instead of doing this
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
ceph orch daemon add osd *<host>*:*<path-to-device>*
|
|
|
|
for each device and each host, we can define a yaml|json file that allows us to describe
|
|
the layout. Here's the most basic example.
|
|
|
|
Create a file called i.e. osd_spec.yml
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: default_drive_group <- name of the drive_group (name can be custom)
|
|
placement:
|
|
host_pattern: '*' <- which hosts to target, currently only supports globs
|
|
data_devices: <- the type of devices you are applying specs to
|
|
all: true <- a filter, check below for a full list
|
|
|
|
This would translate to:
|
|
|
|
Turn any available(ceph-volume decides what 'available' is) into an OSD on all hosts that match
|
|
the glob pattern '*'. (The glob pattern matches against the registered hosts from `host ls`)
|
|
There will be a more detailed section on host_pattern down below.
|
|
|
|
and pass it to `osd create` like so
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
ceph orch apply osd -i /path/to/osd_spec.yml
|
|
|
|
This will go out on all the matching hosts and deploy these OSDs.
|
|
|
|
Since we want to have more complex setups, there are more filters than just the 'all' filter.
|
|
|
|
Also, there is a `--dry-run` flag that can be passed to the `apply osd` command, which gives you a synopsis
|
|
of the proposed layout.
|
|
|
|
Example
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
[monitor.1]# ceph orch apply osd -i /path/to/osd_spec.yml --dry-run
|
|
|
|
|
|
|
|
Filters
|
|
-------
|
|
|
|
.. note::
|
|
Filters are applied using a `AND` gate by default. This essentially means that a drive needs to fulfill all filter
|
|
criteria in order to get selected.
|
|
If you wish to change this behavior you can adjust this behavior by setting
|
|
|
|
`filter_logic: OR` # valid arguments are `AND`, `OR`
|
|
|
|
in the OSD Specification.
|
|
|
|
You can assign disks to certain groups by their attributes using filters.
|
|
|
|
The attributes are based off of ceph-volume's disk query. You can retrieve the information
|
|
with
|
|
|
|
.. code-block:: bash
|
|
|
|
ceph-volume inventory </path/to/disk>
|
|
|
|
Vendor or Model:
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
You can target specific disks by their Vendor or by their Model
|
|
|
|
.. code-block:: yaml
|
|
|
|
model: disk_model_name
|
|
|
|
or
|
|
|
|
.. code-block:: yaml
|
|
|
|
vendor: disk_vendor_name
|
|
|
|
|
|
Size:
|
|
^^^^^
|
|
|
|
You can also match by disk `Size`.
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: size_spec
|
|
|
|
Size specs:
|
|
___________
|
|
|
|
Size specification of format can be of form:
|
|
|
|
* LOW:HIGH
|
|
* :HIGH
|
|
* LOW:
|
|
* EXACT
|
|
|
|
Concrete examples:
|
|
|
|
Includes disks of an exact size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '10G'
|
|
|
|
Includes disks which size is within the range
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '10G:40G'
|
|
|
|
Includes disks less than or equal to 10G in size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: ':10G'
|
|
|
|
|
|
Includes disks equal to or greater than 40G in size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '40G:'
|
|
|
|
Sizes don't have to be exclusively in Gigabyte(G).
|
|
|
|
Supported units are Megabyte(M), Gigabyte(G) and Terrabyte(T). Also appending the (B) for byte is supported. MB, GB, TB
|
|
|
|
|
|
Rotational:
|
|
^^^^^^^^^^^
|
|
|
|
This operates on the 'rotational' attribute of the disk.
|
|
|
|
.. code-block:: yaml
|
|
|
|
rotational: 0 | 1
|
|
|
|
`1` to match all disks that are rotational
|
|
|
|
`0` to match all disks that are non-rotational (SSD, NVME etc)
|
|
|
|
|
|
All:
|
|
^^^^
|
|
|
|
This will take all disks that are 'available'
|
|
|
|
Note: This is exclusive for the data_devices section.
|
|
|
|
.. code-block:: yaml
|
|
|
|
all: true
|
|
|
|
|
|
Limiter:
|
|
^^^^^^^^
|
|
|
|
When you specified valid filters but want to limit the amount of matching disks you can use the 'limit' directive.
|
|
|
|
.. code-block:: yaml
|
|
|
|
limit: 2
|
|
|
|
For example, if you used `vendor` to match all disks that are from `VendorA` but only want to use the first two
|
|
you could use `limit`.
|
|
|
|
.. code-block:: yaml
|
|
|
|
data_devices:
|
|
vendor: VendorA
|
|
limit: 2
|
|
|
|
Note: Be aware that `limit` is really just a last resort and shouldn't be used if it can be avoided.
|
|
|
|
|
|
Additional Options
|
|
------------------
|
|
|
|
There are multiple optional settings you can use to change the way OSDs are deployed.
|
|
You can add these options to the base level of a DriveGroup for it to take effect.
|
|
|
|
This example would deploy all OSDs with encryption enabled.
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: example_osd_spec
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
all: true
|
|
encrypted: true
|
|
|
|
See a full list in the DriveGroupSpecs
|
|
|
|
.. py:currentmodule:: ceph.deployment.drive_group
|
|
|
|
.. autoclass:: DriveGroupSpec
|
|
:members:
|
|
:exclude-members: from_json
|
|
|
|
Examples
|
|
--------
|
|
|
|
The simple case
|
|
^^^^^^^^^^^^^^^
|
|
|
|
All nodes with the same setup
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: HDD-123-foo
|
|
Size: 4TB
|
|
|
|
2 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
This is a common setup and can be described quite easily:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: HDD-123-foo <- note that HDD-123 would also be valid
|
|
db_devices:
|
|
model: MC-55-44-XZ <- same here, MC-55-44 is valid
|
|
|
|
However, we can improve it by reducing the filters on core properties of the drives:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
rotational: 1
|
|
db_devices:
|
|
rotational: 0
|
|
|
|
Now, we enforce all rotating devices to be declared as 'data devices' and all non-rotating devices will be used as shared_devices (wal, db)
|
|
|
|
If you know that drives with more than 2TB will always be the slower data devices, you can also filter by size:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
size: '2TB:'
|
|
db_devices:
|
|
size: ':2TB'
|
|
|
|
Note: All of the above DriveGroups are equally valid. Which of those you want to use depends on taste and on how much you expect your node layout to change.
|
|
|
|
|
|
The advanced case
|
|
^^^^^^^^^^^^^^^^^
|
|
|
|
Here we have two distinct setups
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: HDD-123-foo
|
|
Size: 4TB
|
|
|
|
12 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
2 NVMEs
|
|
Vendor: VendorC
|
|
Model: NVME-QQQQ-987
|
|
Size: 256GB
|
|
|
|
|
|
* 20 HDDs should share 2 SSDs
|
|
* 10 SSDs should share 2 NVMes
|
|
|
|
This can be described with two layouts.
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_hdd
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
rotational: 0
|
|
db_devices:
|
|
model: MC-55-44-XZ
|
|
limit: 2 (db_slots is actually to be favoured here, but it's not implemented yet)
|
|
---
|
|
service_type: osd
|
|
service_id: osd_spec_ssd
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
vendor: VendorC
|
|
|
|
This would create the desired layout by using all HDDs as data_devices with two SSD assigned as dedicated db/wal devices.
|
|
The remaining SSDs(8) will be data_devices that have the 'VendorC' NVMEs assigned as dedicated db/wal devices.
|
|
|
|
The advanced case (with non-uniform nodes)
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The examples above assumed that all nodes have the same drives. That's however not always the case.
|
|
|
|
Node1-5
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: Intel
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
2 SSDs
|
|
Vendor: VendorA
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
Node6-10
|
|
|
|
.. code-block:: none
|
|
|
|
5 NVMEs
|
|
Vendor: Intel
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
20 SSDs
|
|
Vendor: VendorA
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
You can use the 'host_pattern' key in the layout to target certain nodes. Salt target notation helps to keep things easy.
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_node_one_to_five
|
|
placement:
|
|
host_pattern: 'node[1-5]'
|
|
data_devices:
|
|
rotational: 1
|
|
db_devices:
|
|
rotational: 0
|
|
---
|
|
service_type: osd
|
|
service_id: osd_spec_six_to_ten
|
|
placement:
|
|
host_pattern: 'node[6-10]'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
model: SSD-123-foo
|
|
|
|
This applies different OSD specs to different hosts depending on the `host_pattern` key.
|
|
|
|
Dedicated wal + db
|
|
^^^^^^^^^^^^^^^^^^
|
|
|
|
All previous cases co-located the WALs with the DBs.
|
|
It's however possible to deploy the WAL on a dedicated device as well, if it makes sense.
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
|
|
2 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
2 NVMEs
|
|
Vendor: VendorC
|
|
Model: NVME-QQQQ-987
|
|
Size: 256GB
|
|
|
|
|
|
The OSD spec for this case would look like the following (using the `model` filter):
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
model: SSD-123-foo
|
|
wal_devices:
|
|
model: NVME-QQQQ-987
|
|
|
|
|
|
It is also possible to specify directly device paths in specific hosts like the following:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_using_paths
|
|
placement:
|
|
hosts:
|
|
- Node01
|
|
- Node02
|
|
data_devices:
|
|
paths:
|
|
- /dev/sdb
|
|
db_devices:
|
|
paths:
|
|
- /dev/sdc
|
|
wal_devices:
|
|
paths:
|
|
- /dev/sdd
|
|
|
|
|
|
This can easily be done with other filters, like `size` or `vendor` as well.
|
|
|
|
Activate existing OSDs
|
|
======================
|
|
|
|
In case the OS of a host was reinstalled, existing OSDs need to be activated
|
|
again. For this use case, cephadm provides a wrapper for :ref:`ceph-volume-lvm-activate` that
|
|
activates all existing OSDs on a host.
|
|
|
|
.. prompt:: bash #
|
|
|
|
ceph cephadm osd activate <host>...
|
|
|
|
This will scan all existing disks for OSDs and deploy corresponding daemons.
|