.. _rados_operations_bluestore_migration:
|
|
|
|
=====================
|
|
BlueStore Migration
|
|
=====================
|
|
.. warning:: Filestore has been deprecated in the Reef release and is no longer supported.
|
|
Please migrate to BlueStore.
|
|
|
|
Each OSD must be formatted as either Filestore or BlueStore. However, a Ceph
|
|
cluster can operate with a mixture of both Filestore OSDs and BlueStore OSDs.
|
|
Because BlueStore is superior to Filestore in performance and robustness, and
|
|
because Filestore is not supported by Ceph releases beginning with Reef, users
|
|
deploying Filestore OSDs should transition to BlueStore. There are several
|
|
strategies for making the transition to BlueStore.
|
|
|
|
BlueStore is so different from Filestore that an individual OSD cannot be
|
|
converted in place. Instead, the conversion process must use either (1) the
|
|
cluster's normal replication and healing support, or (2) tools and strategies
|
|
that copy OSD content from an old (Filestore) device to a new (BlueStore) one.
|
|
|
|
Deploying new OSDs with BlueStore
|
|
=================================
|
|
|
|
Use BlueStore when deploying new OSDs (for example, when the cluster is
|
|
expanded). Because this is the default behavior, no specific change is
|
|
needed.
|
|
|
|
Similarly, use BlueStore for any OSDs that have been reprovisioned after
|
|
a failed drive was replaced.
|
|
|
|
Converting existing OSDs
|
|
========================
|
|
|
|
"Mark-``out``" replacement
|
|
--------------------------
|
|
|
|
The simplest approach is to verify that the cluster is healthy and
|
|
then follow these steps for each Filestore OSD in succession: mark the OSD
|
|
``out``, wait for the data to replicate across the cluster, reprovision the OSD,
|
|
mark the OSD back ``in``, and wait for recovery to complete before proceeding
|
|
to the next OSD. This approach is easy to automate, but it entails unnecessary
|
|
data migration that carries costs in time and SSD wear.
|
|
|
|
#. Identify a Filestore OSD to replace::
|
|
|
|
ID=<osd-id-number>
|
|
DEVICE=<disk-device>
|
|
|
|
#. Determine whether a given OSD is Filestore or BlueStore:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd metadata $ID | grep osd_objectstore
|
|
|
|
#. Get a current count of Filestore and BlueStore OSDs:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd count-metadata osd_objectstore
|
|
|
|
#. Mark a Filestore OSD ``out``:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd out $ID
|
|
|
|
#. Wait for the data to migrate off this OSD:
|
|
|
|
.. prompt:: bash $
|
|
|
|
while ! ceph osd safe-to-destroy $ID ; do sleep 60 ; done
|
|
|
|
#. Stop the OSD:
|
|
|
|
.. prompt:: bash $
|
|
|
|
systemctl kill ceph-osd@$ID
|
|
|
|
.. _osd_id_retrieval:
|
|
|
|
#. Note which device the OSD is using:
|
|
|
|
.. prompt:: bash $
|
|
|
|
mount | grep /var/lib/ceph/osd/ceph-$ID
|
|
|
|
#. Unmount the OSD:
|
|
|
|
.. prompt:: bash $
|
|
|
|
umount /var/lib/ceph/osd/ceph-$ID
|
|
|
|
#. Destroy the OSD's data. Be *EXTREMELY CAREFUL*! These commands will destroy
|
|
the contents of the device; you must be certain that the data on the device is
|
|
not needed (in other words, that the cluster is healthy) before proceeding:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph-volume lvm zap $DEVICE
|
|
|
|
#. Tell the cluster that the OSD has been destroyed (and that a new OSD can be
|
|
reprovisioned with the same OSD ID):
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd destroy $ID --yes-i-really-mean-it
|
|
|
|
#. Provision a BlueStore OSD in place by using the same OSD ID. This requires
|
|
you to identify which device to wipe, and to make certain that you target
|
|
the correct and intended device, using the information that was retrieved in
|
|
the :ref:`"Note which device the OSD is using" <osd_id_retrieval>` step. BE
|
|
CAREFUL! Note that you may need to modify these commands when dealing with
|
|
hybrid OSDs:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph-volume lvm create --bluestore --data $DEVICE --osd-id $ID
|
|
|
|
#. Repeat.
|
|
|
|
You may opt to (1) have the balancing of the replacement BlueStore OSD take
|
|
place concurrently with the draining of the next Filestore OSD, or instead
|
|
(2) follow the same procedure for multiple OSDs in parallel. In either case,
|
|
however, you must ensure that the cluster is fully clean (in other words, that
|
|
all data has all replicas) before destroying any OSDs. If you opt to reprovision
|
|
multiple OSDs in parallel, be **very** careful to destroy OSDs only within a
|
|
single CRUSH failure domain (for example, ``host`` or ``rack``). Failure to
|
|
satisfy this requirement will reduce the redundancy and availability of your
|
|
data and increase the risk of data loss (or even guarantee data loss).
|
|
|
|
Advantages:
|
|
|
|
* Simple.
|
|
* Can be done on a device-by-device basis.
|
|
* No spare devices or hosts are required.
|
|
|
|
Disadvantages:
|
|
|
|
* Data is copied over the network twice: once to another OSD in the cluster (to
|
|
maintain the specified number of replicas), and again back to the
|
|
reprovisioned BlueStore OSD.
|
|
|
|
"Whole host" replacement
|
|
------------------------
|
|
|
|
If you have a spare host in the cluster, or sufficient free space to evacuate
|
|
an entire host for use as a spare, then the conversion can be done on a
|
|
host-by-host basis so that each stored copy of the data is migrated only once.
|
|
|
|
To use this approach, you need an empty host that has no OSDs provisioned.
|
|
There are two ways to do this: either by using a new, empty host that is not
|
|
yet part of the cluster, or by offloading data from an existing host that is
|
|
already part of the cluster.
|
|
|
|
Using a new, empty host
|
|
^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Ideally the host will have roughly the same capacity as each of the other hosts
|
|
you will be converting. Add the host to the CRUSH hierarchy, but do not attach
|
|
it to the root:
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
NEWHOST=<empty-host-name>
|
|
ceph osd crush add-bucket $NEWHOST host
|
|
|
|
Make sure that Ceph packages are installed on the new host.
|
|
|
|
Using an existing host
|
|
^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
If you would like to use an existing host that is already part of the cluster,
|
|
and if there is sufficient free space on that host so that all of its data can
|
|
be migrated off to other cluster hosts, you can do the following (instead of
|
|
using a new, empty host):
|
|
|
|
.. prompt:: bash $
|
|
|
|
OLDHOST=<existing-cluster-host-to-offload>
|
|
ceph osd crush unlink $OLDHOST default
|
|
|
|
where "default" is the immediate ancestor in the CRUSH map. (For
|
|
smaller clusters with unmodified configurations this will normally
|
|
be "default", but it might instead be a rack name.) You should now
|
|
see the host at the top of the OSD tree output with no parent:
|
|
|
|
.. prompt:: bash $
|
|
|
|
bin/ceph osd tree
|
|
|
|
::
|
|
|
|
ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF
|
|
-5 0 host oldhost
|
|
10 ssd 1.00000 osd.10 up 1.00000 1.00000
|
|
11 ssd 1.00000 osd.11 up 1.00000 1.00000
|
|
12 ssd 1.00000 osd.12 up 1.00000 1.00000
|
|
-1 3.00000 root default
|
|
-2 3.00000 host foo
|
|
0 ssd 1.00000 osd.0 up 1.00000 1.00000
|
|
1 ssd 1.00000 osd.1 up 1.00000 1.00000
|
|
2 ssd 1.00000 osd.2 up 1.00000 1.00000
|
|
...
|
|
|
|
If everything looks good, jump directly to the :ref:`"Wait for the data
|
|
migration to complete" <bluestore_data_migration_step>` step below and proceed
|
|
from there to clean up the old OSDs.
|
|
|
|
Migration process
|
|
^^^^^^^^^^^^^^^^^
|
|
|
|
If you're using a new host, start at :ref:`the first step
|
|
<bluestore_migration_process_first_step>`. If you're using an existing host,
|
|
jump to :ref:`this step <bluestore_data_migration_step>`.
|
|
|
|
.. _bluestore_migration_process_first_step:
|
|
|
|
#. Provision new BlueStore OSDs for all devices:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph-volume lvm create --bluestore --data /dev/$DEVICE
|
|
|
|
#. Verify that the new OSDs have joined the cluster:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd tree
|
|
|
|
You should see the new host ``$NEWHOST`` with all of the OSDs beneath
|
|
it, but the host should *not* be nested beneath any other node in the
|
|
hierarchy (like ``root default``). For example, if ``newhost`` is
|
|
the empty host, you might see something like::
|
|
|
|
$ bin/ceph osd tree
|
|
ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF
|
|
-5 0 host newhost
|
|
10 ssd 1.00000 osd.10 up 1.00000 1.00000
|
|
11 ssd 1.00000 osd.11 up 1.00000 1.00000
|
|
12 ssd 1.00000 osd.12 up 1.00000 1.00000
|
|
-1 3.00000 root default
|
|
-2 3.00000 host oldhost1
|
|
0 ssd 1.00000 osd.0 up 1.00000 1.00000
|
|
1 ssd 1.00000 osd.1 up 1.00000 1.00000
|
|
2 ssd 1.00000 osd.2 up 1.00000 1.00000
|
|
...
|
|
|
|
#. Identify the first target host to convert :
|
|
|
|
.. prompt:: bash $
|
|
|
|
OLDHOST=<existing-cluster-host-to-convert>
|
|
|
|
#. Swap the new host into the old host's position in the cluster:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph osd crush swap-bucket $NEWHOST $OLDHOST
|
|
|
|
At this point all data on ``$OLDHOST`` will begin migrating to the OSDs on
|
|
``$NEWHOST``. If there is a difference between the total capacity of the
|
|
old hosts and the total capacity of the new hosts, you may also see some
|
|
data migrate to or from other nodes in the cluster. Provided that the hosts
|
|
are similarly sized, however, this will be a relatively small amount of
|
|
data.
|
|
|
|
.. _bluestore_data_migration_step:
|
|
|
|
#. Wait for the data migration to complete:
|
|
|
|
.. prompt:: bash $
|
|
|
|
while ! ceph osd safe-to-destroy $(ceph osd ls-tree $OLDHOST); do sleep 60 ; done
|
|
|
|
#. Stop all old OSDs on the now-empty ``$OLDHOST``:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ssh $OLDHOST
|
|
systemctl kill ceph-osd.target
|
|
umount /var/lib/ceph/osd/ceph-*
|
|
|
|
#. Destroy and purge the old OSDs:
|
|
|
|
.. prompt:: bash $
|
|
|
|
for osd in `ceph osd ls-tree $OLDHOST`; do
|
|
ceph osd purge $osd --yes-i-really-mean-it
|
|
done
|
|
|
|
#. Wipe the old OSDs. This requires you to identify which devices are to be
|
|
wiped manually. BE CAREFUL! For each device:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph-volume lvm zap $DEVICE
|
|
|
|
#. Use the now-empty host as the new host, and repeat:
|
|
|
|
.. prompt:: bash $
|
|
|
|
NEWHOST=$OLDHOST
|
|
|
|
Advantages:
|
|
|
|
* Data is copied over the network only once.
|
|
* An entire host's OSDs are converted at once.
|
|
* Can be parallelized, to make possible the conversion of multiple hosts at the same time.
|
|
* No host involved in this process needs to have a spare device.
|
|
|
|
Disadvantages:
|
|
|
|
* A spare host is required.
|
|
* An entire host's worth of OSDs will be migrating data at a time. This
|
|
is likely to impact overall cluster performance.
|
|
* All migrated data still makes one full hop over the network.
|
|
|
|
Per-OSD device copy
|
|
-------------------
|
|
A single logical OSD can be converted by using the ``copy`` function
|
|
included in ``ceph-objectstore-tool``. This requires that the host have one or more free
|
|
devices to provision a new, empty BlueStore OSD. For
|
|
example, if each host in your cluster has twelve OSDs, then you need a
|
|
thirteenth unused OSD so that each OSD can be converted before the
|
|
previous OSD is reclaimed to convert the next OSD.
|
|
|
|
Caveats:
|
|
|
|
* This approach requires that we prepare an empty BlueStore OSD but that we do not allocate
|
|
a new OSD ID to it. The ``ceph-volume`` tool does not support such an operation. **IMPORTANT:**
|
|
because the setup of *dmcrypt* is closely tied to the identity of the OSD, this approach does not
|
|
work with encrypted OSDs.
|
|
|
|
* The device must be manually partitioned.
|
|
|
|
* An unsupported user-contributed script that demonstrates this process may be found here:
|
|
https://github.com/ceph/ceph/blob/master/src/script/contrib/ceph-migrate-bluestore.bash
|
|
|
|
Advantages:
|
|
|
|
* Provided that the 'noout' or the 'norecover'/'norebalance' flags are set on the OSD or the
|
|
cluster while the conversion process is underway, little or no data migrates over the
|
|
network during the conversion.
|
|
|
|
Disadvantages:
|
|
|
|
* Tooling is not fully implemented, supported, or documented.
|
|
|
|
* Each host must have an appropriate spare or empty device for staging.
|
|
|
|
* The OSD is offline during the conversion, which means new writes to PGs
|
|
with the OSD in their acting set may not be ideally redundant until the
|
|
subject OSD comes up and recovers. This increases the risk of data
|
|
loss due to an overlapping failure. However, if another OSD fails before
|
|
conversion and startup have completed, the original Filestore OSD can be
|
|
started to provide access to its original data.
|