.. _monitor-config-reference:
|
|
|
|
==========================
|
|
Monitor Config Reference
|
|
==========================
|
|
|
|
Understanding how to configure a :term:`Ceph Monitor` is an important part of
|
|
building a reliable :term:`Ceph Storage Cluster`. **All Ceph Storage Clusters
|
|
have at least one monitor**. The monitor complement usually remains fairly
|
|
consistent, but you can add, remove or replace a monitor in a cluster. See
|
|
`Adding/Removing a Monitor`_ for details.
|
|
|
|
|
|
.. index:: Ceph Monitor; Paxos
|
|
|
|
Background
|
|
==========
|
|
|
|
Ceph Monitors maintain a "master copy" of the :term:`Cluster Map`, which means a
|
|
:term:`Ceph Client` can determine the location of all Ceph Monitors, Ceph OSD
|
|
Daemons, and Ceph Metadata Servers just by connecting to one Ceph Monitor and
|
|
retrieving a current cluster map. Before Ceph Clients can read from or write to
|
|
Ceph OSD Daemons or Ceph Metadata Servers, they must connect to a Ceph Monitor
|
|
first. With a current copy of the cluster map and the CRUSH algorithm, a Ceph
|
|
Client can compute the location for any object. The ability to compute object
|
|
locations allows a Ceph Client to talk directly to Ceph OSD Daemons, which is a
|
|
very important aspect of Ceph's high scalability and performance. See
|
|
`Scalability and High Availability`_ for additional details.
|
|
|
|
The primary role of the Ceph Monitor is to maintain a master copy of the cluster
|
|
map. Ceph Monitors also provide authentication and logging services. Ceph
|
|
Monitors write all changes in the monitor services to a single Paxos instance,
|
|
and Paxos writes the changes to a key/value store for strong consistency. Ceph
|
|
Monitors can query the most recent version of the cluster map during sync
|
|
operations. Ceph Monitors leverage the key/value store's snapshots and iterators
|
|
(using leveldb) to perform store-wide synchronization.
|
|
|
|
.. ditaa::
|
|
/-------------\ /-------------\
|
|
| Monitor | Write Changes | Paxos |
|
|
| cCCC +-------------->+ cCCC |
|
|
| | | |
|
|
+-------------+ \------+------/
|
|
| Auth | |
|
|
+-------------+ | Write Changes
|
|
| Log | |
|
|
+-------------+ v
|
|
| Monitor Map | /------+------\
|
|
+-------------+ | Key / Value |
|
|
| OSD Map | | Store |
|
|
+-------------+ | cCCC |
|
|
| PG Map | \------+------/
|
|
+-------------+ ^
|
|
| MDS Map | | Read Changes
|
|
+-------------+ |
|
|
| cCCC |*---------------------+
|
|
\-------------/
|
|
|
|
|
|
.. deprecated:: version 0.58
|
|
|
|
In Ceph versions 0.58 and earlier, Ceph Monitors use a Paxos instance for
|
|
each service and store the map as a file.
|
|
|
|
.. index:: Ceph Monitor; cluster map
|
|
|
|
Cluster Maps
|
|
------------
|
|
|
|
The cluster map is a composite of maps, including the monitor map, the OSD map,
|
|
the placement group map and the metadata server map. The cluster map tracks a
|
|
number of important things: which processes are ``in`` the Ceph Storage Cluster;
|
|
which processes that are ``in`` the Ceph Storage Cluster are ``up`` and running
|
|
or ``down``; whether, the placement groups are ``active`` or ``inactive``, and
|
|
``clean`` or in some other state; and, other details that reflect the current
|
|
state of the cluster such as the total amount of storage space, and the amount
|
|
of storage used.
|
|
|
|
When there is a significant change in the state of the cluster--e.g., a Ceph OSD
|
|
Daemon goes down, a placement group falls into a degraded state, etc.--the
|
|
cluster map gets updated to reflect the current state of the cluster.
|
|
Additionally, the Ceph Monitor also maintains a history of the prior states of
|
|
the cluster. The monitor map, OSD map, placement group map and metadata server
|
|
map each maintain a history of their map versions. We call each version an
|
|
"epoch."
|
|
|
|
When operating your Ceph Storage Cluster, keeping track of these states is an
|
|
important part of your system administration duties. See `Monitoring a Cluster`_
|
|
and `Monitoring OSDs and PGs`_ for additional details.
|
|
|
|
.. index:: high availability; quorum
|
|
|
|
Monitor Quorum
|
|
--------------
|
|
|
|
Our Configuring ceph section provides a trivial `Ceph configuration file`_ that
|
|
provides for one monitor in the test cluster. A cluster will run fine with a
|
|
single monitor; however, **a single monitor is a single-point-of-failure**. To
|
|
ensure high availability in a production Ceph Storage Cluster, you should run
|
|
Ceph with multiple monitors so that the failure of a single monitor **WILL NOT**
|
|
bring down your entire cluster.
|
|
|
|
When a Ceph Storage Cluster runs multiple Ceph Monitors for high availability,
|
|
Ceph Monitors use `Paxos`_ to establish consensus about the master cluster map.
|
|
A consensus requires a majority of monitors running to establish a quorum for
|
|
consensus about the cluster map (e.g., 1; 2 out of 3; 3 out of 5; 4 out of 6;
|
|
etc.).
|
|
|
|
.. confval:: mon_force_quorum_join
|
|
|
|
.. index:: Ceph Monitor; consistency
|
|
|
|
Consistency
|
|
-----------
|
|
|
|
When you add monitor settings to your Ceph configuration file, you need to be
|
|
aware of some of the architectural aspects of Ceph Monitors. **Ceph imposes
|
|
strict consistency requirements** for a Ceph monitor when discovering another
|
|
Ceph Monitor within the cluster. Whereas, Ceph Clients and other Ceph daemons
|
|
use the Ceph configuration file to discover monitors, monitors discover each
|
|
other using the monitor map (monmap), not the Ceph configuration file.
|
|
|
|
A Ceph Monitor always refers to the local copy of the monmap when discovering
|
|
other Ceph Monitors in the Ceph Storage Cluster. Using the monmap instead of the
|
|
Ceph configuration file avoids errors that could break the cluster (e.g., typos
|
|
in ``ceph.conf`` when specifying a monitor address or port). Since monitors use
|
|
monmaps for discovery and they share monmaps with clients and other Ceph
|
|
daemons, **the monmap provides monitors with a strict guarantee that their
|
|
consensus is valid.**
|
|
|
|
Strict consistency also applies to updates to the monmap. As with any other
|
|
updates on the Ceph Monitor, changes to the monmap always run through a
|
|
distributed consensus algorithm called `Paxos`_. The Ceph Monitors must agree on
|
|
each update to the monmap, such as adding or removing a Ceph Monitor, to ensure
|
|
that each monitor in the quorum has the same version of the monmap. Updates to
|
|
the monmap are incremental so that Ceph Monitors have the latest agreed upon
|
|
version, and a set of previous versions. Maintaining a history enables a Ceph
|
|
Monitor that has an older version of the monmap to catch up with the current
|
|
state of the Ceph Storage Cluster.
|
|
|
|
If Ceph Monitors were to discover each other through the Ceph configuration file
|
|
instead of through the monmap, additional risks would be introduced because
|
|
Ceph configuration files are not updated and distributed automatically. Ceph
|
|
Monitors might inadvertently use an older Ceph configuration file, fail to
|
|
recognize a Ceph Monitor, fall out of a quorum, or develop a situation where
|
|
`Paxos`_ is not able to determine the current state of the system accurately.
|
|
|
|
|
|
.. index:: Ceph Monitor; bootstrapping monitors
|
|
|
|
Bootstrapping Monitors
|
|
----------------------
|
|
|
|
In most configuration and deployment cases, tools that deploy Ceph help
|
|
bootstrap the Ceph Monitors by generating a monitor map for you (e.g.,
|
|
``cephadm``, etc). A Ceph Monitor requires a few explicit
|
|
settings:
|
|
|
|
- **Filesystem ID**: The ``fsid`` is the unique identifier for your
|
|
object store. Since you can run multiple clusters on the same
|
|
hardware, you must specify the unique ID of the object store when
|
|
bootstrapping a monitor. Deployment tools usually do this for you
|
|
(e.g., ``cephadm`` can call a tool like ``uuidgen``), but you
|
|
may specify the ``fsid`` manually too.
|
|
|
|
- **Monitor ID**: A monitor ID is a unique ID assigned to each monitor within
|
|
the cluster. It is an alphanumeric value, and by convention the identifier
|
|
usually follows an alphabetical increment (e.g., ``a``, ``b``, etc.). This
|
|
can be set in a Ceph configuration file (e.g., ``[mon.a]``, ``[mon.b]``, etc.),
|
|
by a deployment tool, or using the ``ceph`` commandline.
|
|
|
|
- **Keys**: The monitor must have secret keys. A deployment tool such as
|
|
``cephadm`` usually does this for you, but you may
|
|
perform this step manually too. See `Monitor Keyrings`_ for details.
|
|
|
|
For additional details on bootstrapping, see `Bootstrapping a Monitor`_.
|
|
|
|
.. index:: Ceph Monitor; configuring monitors
|
|
|
|
Configuring Monitors
|
|
====================
|
|
|
|
To apply configuration settings to the entire cluster, enter the configuration
|
|
settings under ``[global]``. To apply configuration settings to all monitors in
|
|
your cluster, enter the configuration settings under ``[mon]``. To apply
|
|
configuration settings to specific monitors, specify the monitor instance
|
|
(e.g., ``[mon.a]``). By convention, monitor instance names use alpha notation.
|
|
|
|
.. code-block:: ini
|
|
|
|
[global]
|
|
|
|
[mon]
|
|
|
|
[mon.a]
|
|
|
|
[mon.b]
|
|
|
|
[mon.c]
|
|
|
|
|
|
Minimum Configuration
|
|
---------------------
|
|
|
|
The bare minimum monitor settings for a Ceph monitor via the Ceph configuration
|
|
file include a hostname and a network address for each monitor. You can configure
|
|
these under ``[mon]`` or under the entry for a specific monitor.
|
|
|
|
.. code-block:: ini
|
|
|
|
[global]
|
|
mon_host = 10.0.0.2,10.0.0.3,10.0.0.4
|
|
|
|
.. code-block:: ini
|
|
|
|
[mon.a]
|
|
host = hostname1
|
|
mon_addr = 10.0.0.10:6789
|
|
|
|
See the `Network Configuration Reference`_ for details.
|
|
|
|
.. note:: This minimum configuration for monitors assumes that a deployment
|
|
tool generates the ``fsid`` and the ``mon.`` key for you.
|
|
|
|
Once you deploy a Ceph cluster, you **SHOULD NOT** change the IP addresses of
|
|
monitors. However, if you decide to change the monitor's IP address, you
|
|
must follow a specific procedure. See :ref:`Changing a Monitor's IP address` for
|
|
details.
|
|
|
|
Monitors can also be found by clients by using DNS SRV records. See `Monitor lookup through DNS`_ for details.
|
|
|
|
Cluster ID
|
|
----------
|
|
|
|
Each Ceph Storage Cluster has a unique identifier (``fsid``). If specified, it
|
|
usually appears under the ``[global]`` section of the configuration file.
|
|
Deployment tools usually generate the ``fsid`` and store it in the monitor map,
|
|
so the value may not appear in a configuration file. The ``fsid`` makes it
|
|
possible to run daemons for multiple clusters on the same hardware.
|
|
|
|
.. confval:: fsid
|
|
|
|
.. index:: Ceph Monitor; initial members
|
|
|
|
Initial Members
|
|
---------------
|
|
|
|
We recommend running a production Ceph Storage Cluster with at least three Ceph
|
|
Monitors to ensure high availability. When you run multiple monitors, you may
|
|
specify the initial monitors that must be members of the cluster in order to
|
|
establish a quorum. This may reduce the time it takes for your cluster to come
|
|
online.
|
|
|
|
.. code-block:: ini
|
|
|
|
[mon]
|
|
mon_initial_members = a,b,c
|
|
|
|
|
|
.. confval:: mon_initial_members
|
|
|
|
.. index:: Ceph Monitor; data path
|
|
|
|
Data
|
|
----
|
|
|
|
Ceph provides a default path where Ceph Monitors store data. For optimal
|
|
performance in a production Ceph Storage Cluster, we recommend running Ceph
|
|
Monitors on separate hosts and drives from Ceph OSD Daemons. As leveldb uses
|
|
``mmap()`` for writing the data, Ceph Monitors flush their data from memory to disk
|
|
very often, which can interfere with Ceph OSD Daemon workloads if the data
|
|
store is co-located with the OSD Daemons.
|
|
|
|
In Ceph versions 0.58 and earlier, Ceph Monitors store their data in plain files. This
|
|
approach allows users to inspect monitor data with common tools like ``ls``
|
|
and ``cat``. However, this approach didn't provide strong consistency.
|
|
|
|
In Ceph versions 0.59 and later, Ceph Monitors store their data as key/value
|
|
pairs. Ceph Monitors require `ACID`_ transactions. Using a data store prevents
|
|
recovering Ceph Monitors from running corrupted versions through Paxos, and it
|
|
enables multiple modification operations in one single atomic batch, among other
|
|
advantages.
|
|
|
|
Generally, we do not recommend changing the default data location. If you modify
|
|
the default location, we recommend that you make it uniform across Ceph Monitors
|
|
by setting it in the ``[mon]`` section of the configuration file.
|
|
|
|
|
|
.. confval:: mon_data
|
|
.. confval:: mon_data_size_warn
|
|
.. confval:: mon_data_avail_warn
|
|
.. confval:: mon_data_avail_crit
|
|
.. confval:: mon_warn_on_cache_pools_without_hit_sets
|
|
.. confval:: mon_warn_on_crush_straw_calc_version_zero
|
|
.. confval:: mon_warn_on_legacy_crush_tunables
|
|
.. confval:: mon_crush_min_required_version
|
|
.. confval:: mon_warn_on_osd_down_out_interval_zero
|
|
.. confval:: mon_warn_on_slow_ping_ratio
|
|
.. confval:: mon_warn_on_slow_ping_time
|
|
.. confval:: mon_warn_on_pool_no_redundancy
|
|
.. confval:: mon_cache_target_full_warn_ratio
|
|
.. confval:: mon_health_to_clog
|
|
.. confval:: mon_health_to_clog_tick_interval
|
|
.. confval:: mon_health_to_clog_interval
|
|
|
|
.. index:: Ceph Storage Cluster; capacity planning, Ceph Monitor; capacity planning
|
|
|
|
.. _storage-capacity:
|
|
|
|
Storage Capacity
|
|
----------------
|
|
|
|
When a Ceph Storage Cluster gets close to its maximum capacity
|
|
(see``mon_osd_full ratio``), Ceph prevents you from writing to or reading from OSDs
|
|
as a safety measure to prevent data loss. Therefore, letting a
|
|
production Ceph Storage Cluster approach its full ratio is not a good practice,
|
|
because it sacrifices high availability. The default full ratio is ``.95``, or
|
|
95% of capacity. This a very aggressive setting for a test cluster with a small
|
|
number of OSDs.
|
|
|
|
.. tip:: When monitoring your cluster, be alert to warnings related to the
|
|
``nearfull`` ratio. This means that a failure of some OSDs could result
|
|
in a temporary service disruption if one or more OSDs fails. Consider adding
|
|
more OSDs to increase storage capacity.
|
|
|
|
A common scenario for test clusters involves a system administrator removing an
|
|
OSD from the Ceph Storage Cluster, watching the cluster rebalance, then removing
|
|
another OSD, and another, until at least one OSD eventually reaches the full
|
|
ratio and the cluster locks up. We recommend a bit of capacity
|
|
planning even with a test cluster. Planning enables you to gauge how much spare
|
|
capacity you will need in order to maintain high availability. Ideally, you want
|
|
to plan for a series of Ceph OSD Daemon failures where the cluster can recover
|
|
to an ``active+clean`` state without replacing those OSDs
|
|
immediately. Cluster operation continues in the ``active+degraded`` state, but this
|
|
is not ideal for normal operation and should be addressed promptly.
|
|
|
|
The following diagram depicts a simplistic Ceph Storage Cluster containing 33
|
|
Ceph Nodes with one OSD per host, each OSD reading from
|
|
and writing to a 3TB drive. So this exemplary Ceph Storage Cluster has a maximum
|
|
actual capacity of 99TB. With a ``mon osd full ratio`` of ``0.95``, if the Ceph
|
|
Storage Cluster falls to 5TB of remaining capacity, the cluster will not allow
|
|
Ceph Clients to read and write data. So the Ceph Storage Cluster's operating
|
|
capacity is 95TB, not 99TB.
|
|
|
|
.. ditaa::
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| Rack 1 | | Rack 2 | | Rack 3 | | Rack 4 | | Rack 5 | | Rack 6 |
|
|
| cCCC | | cF00 | | cCCC | | cCCC | | cCCC | | cCCC |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 1 | | OSD 7 | | OSD 13 | | OSD 19 | | OSD 25 | | OSD 31 |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 2 | | OSD 8 | | OSD 14 | | OSD 20 | | OSD 26 | | OSD 32 |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 3 | | OSD 9 | | OSD 15 | | OSD 21 | | OSD 27 | | OSD 33 |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 4 | | OSD 10 | | OSD 16 | | OSD 22 | | OSD 28 | | Spare |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 5 | | OSD 11 | | OSD 17 | | OSD 23 | | OSD 29 | | Spare |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
| OSD 6 | | OSD 12 | | OSD 18 | | OSD 24 | | OSD 30 | | Spare |
|
|
+--------+ +--------+ +--------+ +--------+ +--------+ +--------+
|
|
|
|
It is normal in such a cluster for one or two OSDs to fail. A less frequent but
|
|
reasonable scenario involves a rack's router or power supply failing, which
|
|
brings down multiple OSDs simultaneously (e.g., OSDs 7-12). In such a scenario,
|
|
you should still strive for a cluster that can remain operational and achieve an
|
|
``active + clean`` state--even if that means adding a few hosts with additional
|
|
OSDs in short order. If your capacity utilization is too high, you may not lose
|
|
data, but you could still sacrifice data availability while resolving an outage
|
|
within a failure domain if capacity utilization of the cluster exceeds the full
|
|
ratio. For this reason, we recommend at least some rough capacity planning.
|
|
|
|
Identify two numbers for your cluster:
|
|
|
|
#. The number of OSDs.
|
|
#. The total capacity of the cluster
|
|
|
|
If you divide the total capacity of your cluster by the number of OSDs in your
|
|
cluster, you will find the mean average capacity of an OSD within your cluster.
|
|
Consider multiplying that number by the number of OSDs you expect will fail
|
|
simultaneously during normal operations (a relatively small number). Finally
|
|
multiply the capacity of the cluster by the full ratio to arrive at a maximum
|
|
operating capacity; then, subtract the number of amount of data from the OSDs
|
|
you expect to fail to arrive at a reasonable full ratio. Repeat the foregoing
|
|
process with a higher number of OSD failures (e.g., a rack of OSDs) to arrive at
|
|
a reasonable number for a near full ratio.
|
|
|
|
The following settings only apply on cluster creation and are then stored in
|
|
the OSDMap. To clarify, in normal operation the values that are used by OSDs
|
|
are those found in the OSDMap, not those in the configuration file or central
|
|
config store.
|
|
|
|
.. code-block:: ini
|
|
|
|
[global]
|
|
mon_osd_full_ratio = .80
|
|
mon_osd_backfillfull_ratio = .75
|
|
mon_osd_nearfull_ratio = .70
|
|
|
|
|
|
``mon_osd_full_ratio``
|
|
|
|
:Description: The threshold percentage of device space utilized before an OSD is
|
|
considered ``full``.
|
|
|
|
:Type: Float
|
|
:Default: ``0.95``
|
|
|
|
|
|
``mon_osd_backfillfull_ratio``
|
|
|
|
:Description: The threshold percentage of device space utilized before an OSD is
|
|
considered too ``full`` to backfill.
|
|
|
|
:Type: Float
|
|
:Default: ``0.90``
|
|
|
|
|
|
``mon_osd_nearfull_ratio``
|
|
|
|
:Description: The threshold percentage of device space used before an OSD is
|
|
considered ``nearfull``.
|
|
|
|
:Type: Float
|
|
:Default: ``0.85``
|
|
|
|
|
|
.. tip:: If some OSDs are nearfull, but others have plenty of capacity, you
|
|
may have an inaccurate CRUSH weight set for the nearfull OSDs.
|
|
|
|
.. tip:: These settings only apply during cluster creation. Afterwards they need
|
|
to be changed in the OSDMap using ``ceph osd set-nearfull-ratio`` and
|
|
``ceph osd set-full-ratio``
|
|
|
|
.. index:: heartbeat
|
|
|
|
Heartbeat
|
|
---------
|
|
|
|
Ceph monitors know about the cluster by requiring reports from each OSD, and by
|
|
receiving reports from OSDs about the status of their neighboring OSDs. Ceph
|
|
provides reasonable default settings for monitor/OSD interaction; however, you
|
|
may modify them as needed. See `Monitor/OSD Interaction`_ for details.
|
|
|
|
|
|
.. index:: Ceph Monitor; leader, Ceph Monitor; provider, Ceph Monitor; requester, Ceph Monitor; synchronization
|
|
|
|
Monitor Store Synchronization
|
|
-----------------------------
|
|
|
|
When you run a production cluster with multiple monitors (recommended), each
|
|
monitor checks to see if a neighboring monitor has a more recent version of the
|
|
cluster map (e.g., a map in a neighboring monitor with one or more epoch numbers
|
|
higher than the most current epoch in the map of the instant monitor).
|
|
Periodically, one monitor in the cluster may fall behind the other monitors to
|
|
the point where it must leave the quorum, synchronize to retrieve the most
|
|
current information about the cluster, and then rejoin the quorum. For the
|
|
purposes of synchronization, monitors may assume one of three roles:
|
|
|
|
#. **Leader**: The `Leader` is the first monitor to achieve the most recent
|
|
Paxos version of the cluster map.
|
|
|
|
#. **Provider**: The `Provider` is a monitor that has the most recent version
|
|
of the cluster map, but wasn't the first to achieve the most recent version.
|
|
|
|
#. **Requester:** A `Requester` is a monitor that has fallen behind the leader
|
|
and must synchronize in order to retrieve the most recent information about
|
|
the cluster before it can rejoin the quorum.
|
|
|
|
These roles enable a leader to delegate synchronization duties to a provider,
|
|
which prevents synchronization requests from overloading the leader--improving
|
|
performance. In the following diagram, the requester has learned that it has
|
|
fallen behind the other monitors. The requester asks the leader to synchronize,
|
|
and the leader tells the requester to synchronize with a provider.
|
|
|
|
|
|
.. ditaa::
|
|
+-----------+ +---------+ +----------+
|
|
| Requester | | Leader | | Provider |
|
|
+-----------+ +---------+ +----------+
|
|
| | |
|
|
| | |
|
|
| Ask to Synchronize | |
|
|
|------------------->| |
|
|
| | |
|
|
|<-------------------| |
|
|
| Tell Requester to | |
|
|
| Sync with Provider | |
|
|
| | |
|
|
| Synchronize |
|
|
|--------------------+-------------------->|
|
|
| | |
|
|
|<-------------------+---------------------|
|
|
| Send Chunk to Requester |
|
|
| (repeat as necessary) |
|
|
| Requester Acks Chuck to Provider |
|
|
|--------------------+-------------------->|
|
|
| |
|
|
| Sync Complete |
|
|
| Notification |
|
|
|------------------->|
|
|
| |
|
|
|<-------------------|
|
|
| Ack |
|
|
| |
|
|
|
|
|
|
Synchronization always occurs when a new monitor joins the cluster. During
|
|
runtime operations, monitors may receive updates to the cluster map at different
|
|
times. This means the leader and provider roles may migrate from one monitor to
|
|
another. If this happens while synchronizing (e.g., a provider falls behind the
|
|
leader), the provider can terminate synchronization with a requester.
|
|
|
|
Once synchronization is complete, Ceph performs trimming across the cluster.
|
|
Trimming requires that the placement groups are ``active+clean``.
|
|
|
|
|
|
.. confval:: mon_sync_timeout
|
|
.. confval:: mon_sync_max_payload_size
|
|
.. confval:: paxos_max_join_drift
|
|
.. confval:: paxos_stash_full_interval
|
|
.. confval:: paxos_propose_interval
|
|
.. confval:: paxos_min
|
|
.. confval:: paxos_min_wait
|
|
.. confval:: paxos_trim_min
|
|
.. confval:: paxos_trim_max
|
|
.. confval:: paxos_service_trim_min
|
|
.. confval:: paxos_service_trim_max
|
|
.. confval:: paxos_service_trim_max_multiplier
|
|
.. confval:: mon_mds_force_trim_to
|
|
.. confval:: mon_osd_force_trim_to
|
|
.. confval:: mon_osd_cache_size
|
|
.. confval:: mon_election_timeout
|
|
.. confval:: mon_lease
|
|
.. confval:: mon_lease_renew_interval_factor
|
|
.. confval:: mon_lease_ack_timeout_factor
|
|
.. confval:: mon_accept_timeout_factor
|
|
.. confval:: mon_min_osdmap_epochs
|
|
.. confval:: mon_max_log_epochs
|
|
|
|
|
|
.. index:: Ceph Monitor; clock
|
|
|
|
Clock
|
|
-----
|
|
|
|
Ceph daemons pass critical messages to each other, which must be processed
|
|
before daemons reach a timeout threshold. If the clocks in Ceph monitors
|
|
are not synchronized, it can lead to a number of anomalies. For example:
|
|
|
|
- Daemons ignoring received messages (e.g., timestamps outdated)
|
|
- Timeouts triggered too soon/late when a message wasn't received in time.
|
|
|
|
See `Monitor Store Synchronization`_ for details.
|
|
|
|
|
|
.. tip:: You must configure NTP or PTP daemons on your Ceph monitor hosts to
|
|
ensure that the monitor cluster operates with synchronized clocks.
|
|
It can be advantageous to have monitor hosts sync with each other
|
|
as well as with multiple quality upstream time sources.
|
|
|
|
Clock drift may still be noticeable with NTP even though the discrepancy is not
|
|
yet harmful. Ceph's clock drift / clock skew warnings may get triggered even
|
|
though NTP maintains a reasonable level of synchronization. Increasing your
|
|
clock drift may be tolerable under such circumstances; however, a number of
|
|
factors such as workload, network latency, configuring overrides to default
|
|
timeouts and the `Monitor Store Synchronization`_ settings may influence
|
|
the level of acceptable clock drift without compromising Paxos guarantees.
|
|
|
|
Ceph provides the following tunable options to allow you to find
|
|
acceptable values.
|
|
|
|
.. confval:: mon_tick_interval
|
|
.. confval:: mon_clock_drift_allowed
|
|
.. confval:: mon_clock_drift_warn_backoff
|
|
.. confval:: mon_timecheck_interval
|
|
.. confval:: mon_timecheck_skew_interval
|
|
|
|
Client
|
|
------
|
|
|
|
.. confval:: mon_client_hunt_interval
|
|
.. confval:: mon_client_ping_interval
|
|
.. confval:: mon_client_max_log_entries_per_message
|
|
.. confval:: mon_client_bytes
|
|
|
|
.. _pool-settings:
|
|
|
|
Pool settings
|
|
=============
|
|
|
|
Since version v0.94 there is support for pool flags which allow or disallow changes to be made to pools.
|
|
Monitors can also disallow removal of pools if appropriately configured. The inconvenience of this guardrail
|
|
is far outweighed by the number of accidental pool (and thus data) deletions it prevents.
|
|
|
|
.. confval:: mon_allow_pool_delete
|
|
.. confval:: osd_pool_default_ec_fast_read
|
|
.. confval:: osd_pool_default_flag_hashpspool
|
|
.. confval:: osd_pool_default_flag_nodelete
|
|
.. confval:: osd_pool_default_flag_nopgchange
|
|
.. confval:: osd_pool_default_flag_nosizechange
|
|
|
|
For more information about the pool flags see :ref:`Pool values <setpoolvalues>`.
|
|
|
|
Miscellaneous
|
|
=============
|
|
|
|
.. confval:: mon_max_osd
|
|
.. confval:: mon_globalid_prealloc
|
|
.. confval:: mon_subscribe_interval
|
|
.. confval:: mon_stat_smooth_intervals
|
|
.. confval:: mon_probe_timeout
|
|
.. confval:: mon_daemon_bytes
|
|
.. confval:: mon_max_log_entries_per_event
|
|
.. confval:: mon_osd_prime_pg_temp
|
|
.. confval:: mon_osd_prime_pg_temp_max_time
|
|
.. confval:: mon_osd_prime_pg_temp_max_estimate
|
|
.. confval:: mon_mds_skip_sanity
|
|
.. confval:: mon_max_mdsmap_epochs
|
|
.. confval:: mon_config_key_max_entry_size
|
|
.. confval:: mon_scrub_interval
|
|
.. confval:: mon_scrub_max_keys
|
|
.. confval:: mon_compact_on_start
|
|
.. confval:: mon_compact_on_bootstrap
|
|
.. confval:: mon_compact_on_trim
|
|
.. confval:: mon_cpu_threads
|
|
.. confval:: mon_osd_mapping_pgs_per_chunk
|
|
.. confval:: mon_session_timeout
|
|
.. confval:: mon_osd_cache_size_min
|
|
.. confval:: mon_memory_target
|
|
.. confval:: mon_memory_autotune
|
|
|
|
.. _Paxos: https://en.wikipedia.org/wiki/Paxos_(computer_science)
|
|
.. _Monitor Keyrings: ../../../dev/mon-bootstrap#secret-keys
|
|
.. _Ceph configuration file: ../ceph-conf/#monitors
|
|
.. _Network Configuration Reference: ../network-config-ref
|
|
.. _Monitor lookup through DNS: ../mon-lookup-dns
|
|
.. _ACID: https://en.wikipedia.org/wiki/ACID
|
|
.. _Adding/Removing a Monitor: ../../operations/add-or-rm-mons
|
|
.. _Monitoring a Cluster: ../../operations/monitoring
|
|
.. _Monitoring OSDs and PGs: ../../operations/monitoring-osd-pg
|
|
.. _Bootstrapping a Monitor: ../../../dev/mon-bootstrap
|
|
.. _Monitor/OSD Interaction: ../mon-osd-interaction
|
|
.. _Scalability and High Availability: ../../../architecture#scalability-and-high-availability
|