mirror of
https://github.com/ceph/ceph
synced 2024-12-22 11:31:55 +00:00
9a9b1515f4
Signed-off-by: Jos Collin <jcollin@redhat.com>
223 lines
6.9 KiB
ReStructuredText
223 lines
6.9 KiB
ReStructuredText
|
|
Terminology
|
|
-----------
|
|
|
|
A Ceph cluster may have zero or more CephFS *filesystems*. CephFS
|
|
filesystems have a human readable name (set in ``fs new``)
|
|
and an integer ID. The ID is called the filesystem cluster ID,
|
|
or *FSCID*.
|
|
|
|
Each CephFS filesystem has a number of *ranks*, one by default,
|
|
which start at zero. A rank may be thought of as a metadata shard.
|
|
Controlling the number of ranks in a filesystem is described
|
|
in :doc:`/cephfs/multimds`
|
|
|
|
Each CephFS ceph-mds process (a *daemon*) initially starts up
|
|
without a rank. It may be assigned one by the monitor cluster.
|
|
A daemon may only hold one rank at a time. Daemons only give up
|
|
a rank when the ceph-mds process stops.
|
|
|
|
If a rank is not associated with a daemon, the rank is
|
|
considered *failed*. Once a rank is assigned to a daemon,
|
|
the rank is considered *up*.
|
|
|
|
A daemon has a *name* that is set statically by the administrator
|
|
when the daemon is first configured. Typical configurations
|
|
use the hostname where the daemon runs as the daemon name.
|
|
|
|
Each time a daemon starts up, it is also assigned a *GID*, which
|
|
is unique to this particular process lifetime of the daemon. The
|
|
GID is an integer.
|
|
|
|
Referring to MDS daemons
|
|
------------------------
|
|
|
|
Most of the administrative commands that refer to an MDS daemon
|
|
accept a flexible argument format that may contain a rank, a GID
|
|
or a name.
|
|
|
|
Where a rank is used, this may optionally be qualified with
|
|
a leading filesystem name or ID. If a daemon is a standby (i.e.
|
|
it is not currently assigned a rank), then it may only be
|
|
referred to by GID or name.
|
|
|
|
For example, if we had an MDS daemon which was called 'myhost',
|
|
had GID 5446, and was assigned rank 0 in the filesystem 'myfs'
|
|
which had FSCID 3, then any of the following would be suitable
|
|
forms of the 'fail' command:
|
|
|
|
::
|
|
|
|
ceph mds fail 5446 # GID
|
|
ceph mds fail myhost # Daemon name
|
|
ceph mds fail 0 # Unqualified rank
|
|
ceph mds fail 3:0 # FSCID and rank
|
|
ceph mds fail myfs:0 # Filesystem name and rank
|
|
|
|
Managing failover
|
|
-----------------
|
|
|
|
If an MDS daemon stops communicating with the monitor, the monitor will
|
|
wait ``mds_beacon_grace`` seconds (default 15 seconds) before marking
|
|
the daemon as *laggy*.
|
|
|
|
Each file system may specify a number of standby daemons to be considered
|
|
healthy. This number includes daemons in standby-replay waiting for a rank to
|
|
fail (remember that a standby-replay daemon will not be assigned to take over a
|
|
failure for another rank or a failure in a another CephFS file system). The
|
|
pool of standby daemons not in replay count towards any file system count.
|
|
Each file system may set the number of standby daemons wanted using:
|
|
|
|
::
|
|
|
|
ceph fs set <fs name> standby_count_wanted <count>
|
|
|
|
Setting ``count`` to 0 will disable the health check.
|
|
|
|
|
|
Configuring standby daemons
|
|
---------------------------
|
|
|
|
There are four configuration settings that control how a daemon
|
|
will behave while in standby:
|
|
|
|
::
|
|
|
|
mds_standby_replay
|
|
mds_standby_for_name
|
|
mds_standby_for_rank
|
|
mds_standby_for_fscid
|
|
|
|
These may be set in the ceph.conf on the host where the MDS daemon
|
|
runs (as opposed to on the monitor). The daemon loads these settings
|
|
when it starts, and sends them to the monitor.
|
|
|
|
By default, if none of these settings are used, all MDS daemons
|
|
which do not hold a rank will be used as standbys for any rank.
|
|
|
|
The settings which associate a standby daemon with a particular
|
|
name or rank do not guarantee that the daemon will *only* be used
|
|
for that rank. They mean that when several standbys are available,
|
|
the associated standby daemon will be used. If a rank is failed,
|
|
and a standby is available, it will be used even if it is associated
|
|
with a different rank or named daemon.
|
|
|
|
mds_standby_replay
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
If this is set to true, then the standby daemon will continuously read
|
|
the metadata journal of an up rank. This will give it
|
|
a warm metadata cache, and speed up the process of failing over
|
|
if the daemon serving the rank fails.
|
|
|
|
An up rank may only have one standby replay daemon assigned to it,
|
|
if two daemons are both set to be standby replay then one of them
|
|
will arbitrarily win, and the other will become a normal non-replay
|
|
standby.
|
|
|
|
Once a daemon has entered the standby replay state, it will only be
|
|
used as a standby for the rank that it is following. If another rank
|
|
fails, this standby replay daemon will not be used as a replacement,
|
|
even if no other standbys are available.
|
|
|
|
*Historical note:* In Ceph prior to v10.2.1, this setting (when ``false``) is
|
|
always true when ``mds_standby_for_*`` is also set.
|
|
|
|
mds_standby_for_name
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Set this to make the standby daemon only take over a failed rank
|
|
if the last daemon to hold it matches this name.
|
|
|
|
mds_standby_for_rank
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Set this to make the standby daemon only take over the specified
|
|
rank. If another rank fails, this daemon will not be used to
|
|
replace it.
|
|
|
|
Use in conjunction with ``mds_standby_for_fscid`` to be specific
|
|
about which filesystem's rank you are targeting, if you have
|
|
multiple filesystems.
|
|
|
|
mds_standby_for_fscid
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
If ``mds_standby_for_rank`` is set, this is simply a qualifier to
|
|
say which filesystem's rank is referred to.
|
|
|
|
If ``mds_standby_for_rank`` is not set, then setting FSCID will
|
|
cause this daemon to target any rank in the specified FSCID. Use
|
|
this if you have a daemon that you want to use for any rank, but
|
|
only within a particular filesystem.
|
|
|
|
mon_force_standby_active
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
This setting is used on monitor hosts. It defaults to true.
|
|
|
|
If it is false, then daemons configured with mds_standby_replay=true
|
|
will **only** become active if the rank/name that they have
|
|
been configured to follow fails. On the other hand, if this
|
|
setting is true, then a daemon configured with mds_standby_replay=true
|
|
may be assigned some other rank.
|
|
|
|
Examples
|
|
--------
|
|
|
|
These are example ceph.conf snippets. In practice you can either
|
|
copy a ceph.conf with all daemons' configuration to all your servers,
|
|
or you can have a different file on each server that contains just
|
|
that server's daemons' configuration.
|
|
|
|
Simple pair
|
|
~~~~~~~~~~~
|
|
|
|
Two MDS daemons 'a' and 'b' acting as a pair, where whichever one is not
|
|
currently assigned a rank will be the standby replay follower
|
|
of the other.
|
|
|
|
::
|
|
|
|
[mds.a]
|
|
mds standby replay = true
|
|
mds standby for rank = 0
|
|
|
|
[mds.b]
|
|
mds standby replay = true
|
|
mds standby for rank = 0
|
|
|
|
Floating standby
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
Three MDS daemons 'a', 'b' and 'c', in a filesystem that has
|
|
``max_mds`` set to 2.
|
|
|
|
::
|
|
|
|
# No explicit configuration required: whichever daemon is
|
|
# not assigned a rank will go into 'standby' and take over
|
|
# for whichever other daemon fails.
|
|
|
|
Two MDS clusters
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
With two filesystems, I have four MDS daemons, and I want two
|
|
to act as a pair for one filesystem and two to act as a pair
|
|
for the other filesystem.
|
|
|
|
::
|
|
|
|
[mds.a]
|
|
mds standby for fscid = 1
|
|
|
|
[mds.b]
|
|
mds standby for fscid = 1
|
|
|
|
[mds.c]
|
|
mds standby for fscid = 2
|
|
|
|
[mds.d]
|
|
mds standby for fscid = 2
|
|
|