.. _drivegroups:
|
|
|
|
=========================
|
|
OSD Service Specification
|
|
=========================
|
|
|
|
:ref:`orchestrator-cli-service-spec` of type ``osd`` are a way to describe a cluster layout using the properties of disks.
|
|
It gives the user an abstract way tell ceph which disks should turn into an OSD
|
|
with which configuration without knowing the specifics of device names and paths.
|
|
|
|
Instead of doing this
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
ceph orch daemon add osd *<host>*:*<path-to-device>*
|
|
|
|
for each device and each host, we can define a yaml|json file that allows us to describe
|
|
the layout. Here's the most basic example.
|
|
|
|
Create a file called i.e. osd_spec.yml
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: default_drive_group <- name of the drive_group (name can be custom)
|
|
placement:
|
|
host_pattern: '*' <- which hosts to target, currently only supports globs
|
|
data_devices: <- the type of devices you are applying specs to
|
|
all: true <- a filter, check below for a full list
|
|
|
|
This would translate to:
|
|
|
|
Turn any available(ceph-volume decides what 'available' is) into an OSD on all hosts that match
|
|
the glob pattern '*'. (The glob pattern matches against the registered hosts from `host ls`)
|
|
There will be a more detailed section on host_pattern down below.
|
|
|
|
and pass it to `osd create` like so
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
ceph orch apply osd -i /path/to/osd_spec.yml
|
|
|
|
This will go out on all the matching hosts and deploy these OSDs.
|
|
|
|
Since we want to have more complex setups, there are more filters than just the 'all' filter.
|
|
|
|
Also, there is a `--dry-run` flag that can be passed to the `apply osd` command, which gives you a synopsis
|
|
of the proposed layout.
|
|
|
|
Example
|
|
|
|
.. prompt:: bash [monitor.1]#
|
|
|
|
[monitor.1]# ceph orch apply osd -i /path/to/osd_spec.yml --dry-run
|
|
|
|
|
|
|
|
Filters
|
|
=======
|
|
|
|
.. note::
|
|
Filters are applied using a `AND` gate by default. This essentially means that a drive needs to fulfill all filter
|
|
criteria in order to get selected.
|
|
If you wish to change this behavior you can adjust this behavior by setting
|
|
|
|
`filter_logic: OR` # valid arguments are `AND`, `OR`
|
|
|
|
in the OSD Specification.
|
|
|
|
You can assign disks to certain groups by their attributes using filters.
|
|
|
|
The attributes are based off of ceph-volume's disk query. You can retrieve the information
|
|
with
|
|
|
|
.. code-block:: bash
|
|
|
|
ceph-volume inventory </path/to/disk>
|
|
|
|
Vendor or Model:
|
|
-------------------
|
|
|
|
You can target specific disks by their Vendor or by their Model
|
|
|
|
.. code-block:: yaml
|
|
|
|
model: disk_model_name
|
|
|
|
or
|
|
|
|
.. code-block:: yaml
|
|
|
|
vendor: disk_vendor_name
|
|
|
|
|
|
Size:
|
|
--------------
|
|
|
|
You can also match by disk `Size`.
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: size_spec
|
|
|
|
Size specs:
|
|
___________
|
|
|
|
Size specification of format can be of form:
|
|
|
|
* LOW:HIGH
|
|
* :HIGH
|
|
* LOW:
|
|
* EXACT
|
|
|
|
Concrete examples:
|
|
|
|
Includes disks of an exact size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '10G'
|
|
|
|
Includes disks which size is within the range
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '10G:40G'
|
|
|
|
Includes disks less than or equal to 10G in size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: ':10G'
|
|
|
|
|
|
Includes disks equal to or greater than 40G in size
|
|
|
|
.. code-block:: yaml
|
|
|
|
size: '40G:'
|
|
|
|
Sizes don't have to be exclusively in Gigabyte(G).
|
|
|
|
Supported units are Megabyte(M), Gigabyte(G) and Terrabyte(T). Also appending the (B) for byte is supported. MB, GB, TB
|
|
|
|
|
|
Rotational:
|
|
-----------
|
|
|
|
This operates on the 'rotational' attribute of the disk.
|
|
|
|
.. code-block:: yaml
|
|
|
|
rotational: 0 | 1
|
|
|
|
`1` to match all disks that are rotational
|
|
|
|
`0` to match all disks that are non-rotational (SSD, NVME etc)
|
|
|
|
|
|
All:
|
|
------------
|
|
|
|
This will take all disks that are 'available'
|
|
|
|
Note: This is exclusive for the data_devices section.
|
|
|
|
.. code-block:: yaml
|
|
|
|
all: true
|
|
|
|
|
|
Limiter:
|
|
--------
|
|
|
|
When you specified valid filters but want to limit the amount of matching disks you can use the 'limit' directive.
|
|
|
|
.. code-block:: yaml
|
|
|
|
limit: 2
|
|
|
|
For example, if you used `vendor` to match all disks that are from `VendorA` but only want to use the first two
|
|
you could use `limit`.
|
|
|
|
.. code-block:: yaml
|
|
|
|
data_devices:
|
|
vendor: VendorA
|
|
limit: 2
|
|
|
|
Note: Be aware that `limit` is really just a last resort and shouldn't be used if it can be avoided.
|
|
|
|
|
|
Additional Options
|
|
===================
|
|
|
|
There are multiple optional settings you can use to change the way OSDs are deployed.
|
|
You can add these options to the base level of a DriveGroup for it to take effect.
|
|
|
|
This example would deploy all OSDs with encryption enabled.
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: example_osd_spec
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
all: true
|
|
encrypted: true
|
|
|
|
See a full list in the DriveGroupSpecs
|
|
|
|
.. py:currentmodule:: ceph.deployment.drive_group
|
|
|
|
.. autoclass:: DriveGroupSpec
|
|
:members:
|
|
:exclude-members: from_json
|
|
|
|
Examples
|
|
========
|
|
|
|
The simple case
|
|
---------------
|
|
|
|
All nodes with the same setup
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: HDD-123-foo
|
|
Size: 4TB
|
|
|
|
2 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
This is a common setup and can be described quite easily:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: HDD-123-foo <- note that HDD-123 would also be valid
|
|
db_devices:
|
|
model: MC-55-44-XZ <- same here, MC-55-44 is valid
|
|
|
|
However, we can improve it by reducing the filters on core properties of the drives:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
rotational: 1
|
|
db_devices:
|
|
rotational: 0
|
|
|
|
Now, we enforce all rotating devices to be declared as 'data devices' and all non-rotating devices will be used as shared_devices (wal, db)
|
|
|
|
If you know that drives with more than 2TB will always be the slower data devices, you can also filter by size:
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
size: '2TB:'
|
|
db_devices:
|
|
size: ':2TB'
|
|
|
|
Note: All of the above DriveGroups are equally valid. Which of those you want to use depends on taste and on how much you expect your node layout to change.
|
|
|
|
|
|
The advanced case
|
|
-----------------
|
|
|
|
Here we have two distinct setups
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: HDD-123-foo
|
|
Size: 4TB
|
|
|
|
12 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
2 NVMEs
|
|
Vendor: VendorC
|
|
Model: NVME-QQQQ-987
|
|
Size: 256GB
|
|
|
|
|
|
* 20 HDDs should share 2 SSDs
|
|
* 10 SSDs should share 2 NVMes
|
|
|
|
This can be described with two layouts.
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_hdd
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
rotational: 0
|
|
db_devices:
|
|
model: MC-55-44-XZ
|
|
limit: 2 (db_slots is actually to be favoured here, but it's not implemented yet)
|
|
---
|
|
service_type: osd
|
|
service_id: osd_spec_ssd
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
vendor: VendorC
|
|
|
|
This would create the desired layout by using all HDDs as data_devices with two SSD assigned as dedicated db/wal devices.
|
|
The remaining SSDs(8) will be data_devices that have the 'VendorC' NVMEs assigned as dedicated db/wal devices.
|
|
|
|
The advanced case (with non-uniform nodes)
|
|
------------------------------------------
|
|
|
|
The examples above assumed that all nodes have the same drives. That's however not always the case.
|
|
|
|
Node1-5
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: Intel
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
2 SSDs
|
|
Vendor: VendorA
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
Node6-10
|
|
|
|
.. code-block:: none
|
|
|
|
5 NVMEs
|
|
Vendor: Intel
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
20 SSDs
|
|
Vendor: VendorA
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
You can use the 'host_pattern' key in the layout to target certain nodes. Salt target notation helps to keep things easy.
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_node_one_to_five
|
|
placement:
|
|
host_pattern: 'node[1-5]'
|
|
data_devices:
|
|
rotational: 1
|
|
db_devices:
|
|
rotational: 0
|
|
---
|
|
service_type: osd
|
|
service_id: osd_spec_six_to_ten
|
|
placement:
|
|
host_pattern: 'node[6-10]'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
model: SSD-123-foo
|
|
|
|
This applies different OSD specs to different hosts depending on the `host_pattern` key.
|
|
|
|
Dedicated wal + db
|
|
------------------
|
|
|
|
All previous cases co-located the WALs with the DBs.
|
|
It's however possible to deploy the WAL on a dedicated device as well, if it makes sense.
|
|
|
|
.. code-block:: none
|
|
|
|
20 HDDs
|
|
Vendor: VendorA
|
|
Model: SSD-123-foo
|
|
Size: 4TB
|
|
|
|
2 SSDs
|
|
Vendor: VendorB
|
|
Model: MC-55-44-ZX
|
|
Size: 512GB
|
|
|
|
2 NVMEs
|
|
Vendor: VendorC
|
|
Model: NVME-QQQQ-987
|
|
Size: 256GB
|
|
|
|
|
|
The OSD spec for this case would look like the following (using the `model` filter):
|
|
|
|
.. code-block:: yaml
|
|
|
|
service_type: osd
|
|
service_id: osd_spec_default
|
|
placement:
|
|
host_pattern: '*'
|
|
data_devices:
|
|
model: MC-55-44-XZ
|
|
db_devices:
|
|
model: SSD-123-foo
|
|
wal_devices:
|
|
model: NVME-QQQQ-987
|
|
|
|
|
|
This can easily be done with other filters, like `size` or `vendor` as well.
|
|
|