ceph/man/ceph-fuse.8

121 lines
2.9 KiB
Groff

.\" Man page generated from reStructuredText.
.
.TH "CEPH-FUSE" "8" "January 12, 2014" "dev" "Ceph"
.SH NAME
ceph-fuse \- FUSE-based client for ceph
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.SH SYNOPSIS
.nf
\fBceph\-fuse\fP [ \-m \fImonaddr\fP:\fIport\fP ] \fImountpoint\fP [ \fIfuse options\fP ]
.fi
.sp
.SH DESCRIPTION
.sp
\fBceph\-fuse\fP is a FUSE (File system in USErspace) client for Ceph
distributed file system. It will mount a ceph file system (specified
via the \-m option for described by ceph.conf (see below) at the
specific mount point.
.sp
The file system can be unmounted with:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
fusermount \-u mountpoint
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
or by sending \fBSIGINT\fP to the \fBceph\-fuse\fP process.
.SH OPTIONS
.sp
Any options not recognized by ceph\-fuse will be passed on to libfuse.
.INDENT 0.0
.TP
.B \-d
Detach from console and daemonize after startup.
.UNINDENT
.INDENT 0.0
.TP
.B \-c ceph.conf, \-\-conf=ceph.conf
Use \fIceph.conf\fP configuration file instead of the default
\fB/etc/ceph/ceph.conf\fP to determine monitor addresses during startup.
.UNINDENT
.INDENT 0.0
.TP
.B \-m monaddress[:port]
Connect to specified monitor (instead of looking through ceph.conf).
.UNINDENT
.INDENT 0.0
.TP
.B \-r root_directory
Use root_directory as the mounted root, rather than the full Ceph tree.
.UNINDENT
.SH AVAILABILITY
.sp
\fBceph\-fuse\fP is part of the Ceph distributed storage system. Please refer to
the Ceph documentation at \fI\%http://ceph.com/docs\fP for more information.
.SH SEE ALSO
.sp
fusermount(8),
\fBceph\fP(8)
.SH COPYRIGHT
2010-2014, Inktank Storage, Inc. and contributors. Licensed under Creative Commons BY-SA
.\" Generated by docutils manpage writer.
.