ceph/man/rbd-replay.8

133 lines
3.0 KiB
Groff

.\" Man page generated from reStructuredText.
.
.TH "RBD-REPLAY" "8" "August 07, 2014" "dev" "Ceph"
.SH NAME
rbd-replay \- replay rados block device (RBD) workloads
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.SH SYNOPSIS
.nf
\fBrbd\-replay\fP [ \fIoptions\fP ] \fIreplay_file\fP
.fi
.sp
.SH DESCRIPTION
.sp
\fBrbd\-replay\fP is a utility for replaying rados block device (RBD) workloads.
.SH OPTIONS
.INDENT 0.0
.TP
.B \-c ceph.conf, \-\-conf ceph.conf
Use ceph.conf configuration file instead of the default /etc/ceph/ceph.conf to
determine monitor addresses during startup.
.UNINDENT
.INDENT 0.0
.TP
.B \-p pool, \-\-pool pool
Interact with the given pool. Defaults to \(aqrbd\(aq.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-latency\-multiplier
Multiplies inter\-request latencies. Default: 1.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-read\-only
Only replay non\-destructive requests.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-map\-image rule
Add a rule to map image names in the trace to image names in the replay cluster.
A rule of image1@snap1=image2@snap2 would map snap1 of image1 to snap2 of image2.
.UNINDENT
.SH EXAMPLES
.sp
To replay workload1 as fast as possible:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
rbd\-replay \-\-latency\-multiplier=0 workload1
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
To replay workload1 but use test_image instead of prod_image:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
rbd\-replay \-\-map\-image=prod_image=test_image workload1
.ft P
.fi
.UNINDENT
.UNINDENT
.SH AVAILABILITY
.sp
\fBrbd\-replay\fP is part of the Ceph distributed storage system. Please refer to
the Ceph documentation at \fI\%http://ceph.com/docs\fP for more information.
.SH SEE ALSO
.sp
\fBceph\fP(8),
\fBrbd\fP(8)
.SH COPYRIGHT
2010-2014, Inktank Storage, Inc. and contributors. Licensed under Creative Commons BY-SA