the root access to system is not a must have for running a DPDK application. so reword the "Configuring OSD DPDKStack" section. also, manually editing /etc/passwd is not encouraged, so use "usermod" instead. to add a directory after user's command interpreter in /etc/passwd does not make sense. see PASSWD(5). so drop the paragraph on editing /etc/passwd. Signed-off-by: Kefu Chai <tchaikov@gmail.com>
173 lines
4.4 KiB
ReStructuredText
173 lines
4.4 KiB
ReStructuredText
=========================
|
|
Ceph messenger DPDKStack
|
|
=========================
|
|
|
|
Compiling DPDKStack
|
|
===================
|
|
|
|
Ceph dpdkstack is not compiled by default. Therefore, you need to recompile and
|
|
enable the DPDKstack component.
|
|
Optionally install ``dpdk-devel`` or ``dpdk-dev`` on distros with precompiled DPDK packages, and compile
|
|
|
|
.. prompt:: bash $
|
|
|
|
do_cmake.sh -DWITH_DPDK=ON
|
|
|
|
|
|
Setting the DPDK Network Adapter
|
|
================================
|
|
|
|
Most mainstream NICs support SR-IOV and can be virtualized into multiple VF NICs.
|
|
Each OSD uses some dedicated NICs through DPDK. The mon, mgr and client use the PF NICs
|
|
through the POSIX protocol stack.
|
|
|
|
Load the driver on which DPDK depends:
|
|
|
|
.. prompt:: bash #
|
|
|
|
modprobe vfio
|
|
modprobe vfio_pci
|
|
|
|
Configure Hugepage by editing ``/etc/sysctl.conf`` ::
|
|
|
|
vm.nr_hugepages = xxx
|
|
|
|
Configure the number of VFs based on the number of OSDs:
|
|
|
|
.. prompt:: bash #
|
|
|
|
echo $numvfs > /sys/class/net/$port/device/sriov_numvfs
|
|
|
|
Binding NICs to DPDK Applications:
|
|
|
|
.. prompt:: bash #
|
|
|
|
dpdk-devbind.py -b vfio-pci 0000:xx:yy.z
|
|
|
|
|
|
Configuring OSD DPDKStack
|
|
==========================
|
|
|
|
By default, the DPDK RTE initialization process requires the root privileges
|
|
for accessing various resources in system. To grant the root access to
|
|
the ``ceph`` user:
|
|
|
|
.. prompt:: bash #
|
|
|
|
usermod -G root ceph
|
|
|
|
The OSD selects the NICs using ``ms_dpdk_devs_allowlist``:
|
|
|
|
#. Configure a single NIC.
|
|
|
|
.. code-block:: ini
|
|
|
|
ms_dpdk_devs_allowlist=-a 0000:7d:010
|
|
|
|
or
|
|
|
|
.. code-block:: ini
|
|
|
|
ms_dpdk_devs_allowlist=--allow=0000:7d:010
|
|
|
|
#. Configure the Bond Network Adapter
|
|
|
|
.. code-block:: ini
|
|
|
|
ms_dpdk_devs_allowlist=--allow=0000:7d:01.0 --allow=0000:7d:02.6 --vdev=net_bonding0,mode=2,slave=0000:7d:01.0,slave=0000:7d:02.6
|
|
|
|
DPDK-related configuration items are as follows:
|
|
|
|
.. code-block:: ini
|
|
|
|
[osd]
|
|
ms_type=async+dpdk
|
|
ms_async_op_threads=1
|
|
|
|
ms_dpdk_port_id=0
|
|
ms_dpdk_gateway_ipv4_addr=172.19.36.1
|
|
ms_dpdk_netmask_ipv4_addr=255.255.255.0
|
|
ms_dpdk_hugepages=/dev/hugepages
|
|
ms_dpdk_hw_flow_control=false
|
|
ms_dpdk_lro=false
|
|
ms_dpdk_enable_tso=false
|
|
ms_dpdk_hw_queue_weight=1
|
|
ms_dpdk_memory_channel=2
|
|
ms_dpdk_debug_allow_loopback = true
|
|
|
|
[osd.x]
|
|
ms_dpdk_coremask=0xf0
|
|
ms_dpdk_host_ipv4_addr=172.19.36.51
|
|
public_addr=172.19.36.51
|
|
cluster_addr=172.19.36.51
|
|
ms_dpdk_devs_allowlist=--allow=0000:7d:01.1
|
|
|
|
Debug and Optimization
|
|
======================
|
|
|
|
Locate faults based on logs and adjust logs to a proper level:
|
|
|
|
.. code-block:: ini
|
|
|
|
debug_dpdk=xx
|
|
debug_ms=xx
|
|
|
|
if the log contains a large number of retransmit messages,reduce the value of ms_dpdk_tcp_wmem.
|
|
|
|
Run the perf dump command to view DPDKStack statistics:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph daemon osd.$i perf dump | grep dpdk
|
|
|
|
|
|
if the ``dpdk_device_receive_nombuf_errors`` keeps increasing, check whether the
|
|
throttling exceeds the limit:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph daemon osd.$i perf dump | grep throttle-osd_client -A 7 | grep "get_or_fail_fail"
|
|
ceph daemon osd.$i perf dump | grep throttle-msgr_dispatch_throttler -A 7 | grep "get_or_fail_fail"
|
|
|
|
if the throttling exceeds the threshold, increase the throttling threshold or
|
|
disable the throttling.
|
|
|
|
Check whether the network adapter is faulty or abnormal.Run the following
|
|
command to obtain the network adapter status and statistics:
|
|
|
|
.. prompt:: bash $
|
|
|
|
ceph daemon osd.$i show_pmd_stats
|
|
ceph daemon osd.$i show_pmd_xstats
|
|
|
|
Some DPDK versions (eg. dpdk-20.11-3.e18.aarch64) or NIC TSOs are abnormal,
|
|
try disabling tso:
|
|
|
|
.. code-block:: ini
|
|
|
|
ms_dpdk_enable_tso=false
|
|
|
|
if VF NICs support multiple queues, more NIC queues can be allocated to a
|
|
single core to improve performance:
|
|
|
|
.. code-block:: ini
|
|
|
|
ms_dpdk_hw_queues_per_qp=4
|
|
|
|
|
|
Status and Future Work
|
|
======================
|
|
|
|
Compared with POSIX Stack, in the multi-concurrency test, DPDKStack has the same
|
|
4K random write performance, 8K random write performance is improved by 28%, and
|
|
1 MB packets are unstable. In the single-latency test,the 4K and 8K random write
|
|
latency is reduced by 15% (the lower the latency is, the better).
|
|
|
|
At a high level, our future work plan is:
|
|
|
|
OSD multiple network support (public network and cluster network)
|
|
The public and cluster network adapters can be configured.When connecting or
|
|
listening,the public or cluster network adapters can be selected based on the
|
|
IP address.During msgr-work initialization,initialize both the public and cluster
|
|
network adapters and create two DPDKQueuePairs.
|