#!/usr/bin/env bash
|
|
|
|
set -ex
|
|
|
|
NUM_OSDS_UP=$(ceph osd df | grep "up" | wc -l)
|
|
|
|
if [ $NUM_OSDS_UP -lt 8 ]; then
|
|
echo "test requires at least 8 OSDs up and running"
|
|
exit 1
|
|
fi
|
|
|
|
ceph mon set election_strategy connectivity
|
|
ceph mon add disallowed_leader e
|
|
|
|
for dc in dc1 dc2
|
|
do
|
|
ceph osd crush add-bucket $dc datacenter
|
|
ceph osd crush move $dc root=default
|
|
done
|
|
|
|
ceph osd crush add-bucket node-2 host
|
|
ceph osd crush add-bucket node-3 host
|
|
ceph osd crush add-bucket node-4 host
|
|
ceph osd crush add-bucket node-5 host
|
|
ceph osd crush add-bucket node-6 host
|
|
ceph osd crush add-bucket node-7 host
|
|
ceph osd crush add-bucket node-8 host
|
|
ceph osd crush add-bucket node-9 host
|
|
|
|
ceph osd crush move node-2 datacenter=dc1
|
|
ceph osd crush move node-3 datacenter=dc1
|
|
ceph osd crush move node-4 datacenter=dc1
|
|
ceph osd crush move node-5 datacenter=dc1
|
|
|
|
ceph osd crush move node-6 datacenter=dc2
|
|
ceph osd crush move node-7 datacenter=dc2
|
|
ceph osd crush move node-8 datacenter=dc2
|
|
ceph osd crush move node-9 datacenter=dc2
|
|
|
|
ceph osd crush move osd.0 host=node-2
|
|
ceph osd crush move osd.1 host=node-3
|
|
ceph osd crush move osd.2 host=node-4
|
|
ceph osd crush move osd.3 host=node-5
|
|
|
|
ceph osd crush move osd.4 host=node-6
|
|
ceph osd crush move osd.5 host=node-7
|
|
ceph osd crush move osd.6 host=node-8
|
|
ceph osd crush move osd.7 host=node-9
|
|
|
|
|
|
ceph mon set_location a datacenter=dc1 host=node-2
|
|
ceph mon set_location b datacenter=dc1 host=node-3
|
|
ceph mon set_location c datacenter=dc2 host=node-6
|
|
ceph mon set_location d datacenter=dc2 host=node-7
|
|
|
|
hostname=$(hostname -s)
|
|
ceph osd crush remove $hostname || { echo 'command failed' ; exit 1; }
|
|
ceph osd getcrushmap > crushmap || { echo 'command failed' ; exit 1; }
|
|
crushtool --decompile crushmap > crushmap.txt || { echo 'command failed' ; exit 1; }
|
|
sed 's/^# end crush map$//' crushmap.txt > crushmap_modified.txt || { echo 'command failed' ; exit 1; }
|
|
cat >> crushmap_modified.txt << EOF
|
|
rule stretch_rule {
|
|
id 1
|
|
type replicated
|
|
step take dc1
|
|
step chooseleaf firstn 2 type host
|
|
step emit
|
|
step take dc2
|
|
step chooseleaf firstn 2 type host
|
|
step emit
|
|
}
|
|
# rule stretch_rule {
|
|
# id 1
|
|
# type replicated
|
|
# step take default
|
|
# step chooseleaf firstn 2 type datacenter
|
|
# step chooseleaf firstn 2 type host
|
|
# step emit
|
|
# }
|
|
# end crush map
|
|
EOF
|
|
|
|
crushtool --compile crushmap_modified.txt -o crushmap.bin || { echo 'command failed' ; exit 1; }
|
|
ceph osd setcrushmap -i crushmap.bin || { echo 'command failed' ; exit 1; }
|
|
stretched_poolname=stretch_pool
|
|
ceph osd pool create $stretched_poolname 32 32 stretch_rule || { echo 'command failed' ; exit 1; }
|
|
ceph osd pool set $stretched_poolname size 4 || { echo 'command failed' ; exit 1; }
|
|
ceph osd pool application enable $stretched_poolname rados || { echo 'command failed' ; exit 1; }
|
|
ceph mon set_location e datacenter=arbiter host=node-1 || { echo 'command failed' ; exit 1; }
|
|
ceph mon enable_stretch_mode e stretch_rule datacenter || { echo 'command failed' ; exit 1; } # Enter strech mode
|