.. _placement groups:
|
|
|
|
==================
|
|
Placement Groups
|
|
==================
|
|
|
|
.. _pg-autoscaler:
|
|
|
|
Autoscaling placement groups
|
|
============================
|
|
|
|
Placement groups (PGs) are an internal implementation detail of how
|
|
Ceph distributes data. You may enable *pg-autoscaling* to allow the cluster to
|
|
make recommendations or automatically adjust the numbers of PGs (``pgp_num``)
|
|
for each pool based on expected cluster and pool utilization.
|
|
|
|
Each pool has a ``pg_autoscale_mode`` property that can be set to ``off``, ``on``, or ``warn``.
|
|
|
|
* ``off``: Disable autoscaling for this pool. It is up to the administrator to choose an appropriate ``pgp_num`` for each pool. Please refer to :ref:`choosing-number-of-placement-groups` for more information.
|
|
* ``on``: Enable automated adjustments of the PG count for the given pool.
|
|
* ``warn``: Raise health alerts when the PG count should be adjusted
|
|
|
|
To set the autoscaling mode for an existing pool::
|
|
|
|
ceph osd pool set <pool-name> pg_autoscale_mode <mode>
|
|
|
|
For example to enable autoscaling on pool ``foo``::
|
|
|
|
ceph osd pool set foo pg_autoscale_mode on
|
|
|
|
You can also configure the default ``pg_autoscale_mode`` that is
|
|
set on any pools that are subsequently created::
|
|
|
|
ceph config set global osd_pool_default_pg_autoscale_mode <mode>
|
|
|
|
You can disable or enable the autoscaler for all pools with
|
|
the ``noautoscale`` flag. By default this flag is set to be ``off``,
|
|
but you can turn it ``on`` by using the command::
|
|
|
|
ceph osd pool set noautoscale
|
|
|
|
You can turn it ``off`` using the command::
|
|
|
|
ceph osd pool unset noautoscale
|
|
|
|
To ``get`` the value of the flag use the command::
|
|
|
|
ceph osd pool get noautoscale
|
|
|
|
Viewing PG scaling recommendations
|
|
----------------------------------
|
|
|
|
You can view each pool, its relative utilization, and any suggested changes to
|
|
the PG count with this command::
|
|
|
|
ceph osd pool autoscale-status
|
|
|
|
Output will be something like::
|
|
|
|
POOL SIZE TARGET SIZE RATE RAW CAPACITY RATIO TARGET RATIO EFFECTIVE RATIO BIAS PG_NUM NEW PG_NUM AUTOSCALE BULK
|
|
a 12900M 3.0 82431M 0.4695 8 128 warn True
|
|
c 0 3.0 82431M 0.0000 0.2000 0.9884 1.0 1 64 warn True
|
|
b 0 953.6M 3.0 82431M 0.0347 8 warn False
|
|
|
|
**SIZE** is the amount of data stored in the pool. **TARGET SIZE**, if
|
|
present, is the amount of data the administrator has specified that
|
|
they expect to eventually be stored in this pool. The system uses
|
|
the larger of the two values for its calculation.
|
|
|
|
**RATE** is the multiplier for the pool that determines how much raw
|
|
storage capacity is consumed. For example, a 3 replica pool will
|
|
have a ratio of 3.0, while a k=4,m=2 erasure coded pool will have a
|
|
ratio of 1.5.
|
|
|
|
**RAW CAPACITY** is the total amount of raw storage capacity on the
|
|
OSDs that are responsible for storing this pool's (and perhaps other
|
|
pools') data. **RATIO** is the ratio of that total capacity that
|
|
this pool is consuming (i.e., ratio = size * rate / raw capacity).
|
|
|
|
**TARGET RATIO**, if present, is the ratio of storage that the
|
|
administrator has specified that they expect this pool to consume
|
|
relative to other pools with target ratios set.
|
|
If both target size bytes and ratio are specified, the
|
|
ratio takes precedence.
|
|
|
|
**EFFECTIVE RATIO** is the target ratio after adjusting in two ways:
|
|
|
|
1. Subtracting any capacity expected to be used by pools with target size set
|
|
2. Normalizing the target ratios among pools with target ratio set so
|
|
they collectively target the rest of the space. For example, 4
|
|
pools with target_ratio 1.0 would have an effective ratio of 0.25.
|
|
|
|
The system uses the larger of the actual ratio and the effective ratio
|
|
for its calculation.
|
|
|
|
**BIAS** is used as a multiplier to manually adjust a pool's PG based
|
|
on prior information about how much PGs a specific pool is expected
|
|
to have.
|
|
|
|
**PG_NUM** is the current number of PGs for the pool (or the current
|
|
number of PGs that the pool is working towards, if a ``pg_num``
|
|
change is in progress). **NEW PG_NUM**, if present, is what the
|
|
system believes the pool's ``pg_num`` should be changed to. It is
|
|
always a power of 2, and will only be present if the "ideal" value
|
|
varies from the current value by more than a factor of 3 by default.
|
|
This factor can be be adjusted with::
|
|
|
|
ceph osd pool set threshold 2.0
|
|
|
|
**AUTOSCALE**, is the pool ``pg_autoscale_mode``
|
|
and will be either ``on``, ``off``, or ``warn``.
|
|
|
|
The final column, **BULK** determines if the pool is ``bulk``
|
|
and will be either ``True`` or ``False``. A ``bulk`` pool
|
|
means that the pool is expected to be large and should start out
|
|
with large amount of PGs for performance purposes. On the other hand,
|
|
pools without the ``bulk`` flag are expected to be smaller e.g.,
|
|
.mgr or meta pools.
|
|
|
|
|
|
Automated scaling
|
|
-----------------
|
|
|
|
Allowing the cluster to automatically scale ``pgp_num`` based on usage is the
|
|
simplest approach. Ceph will look at the total available storage and
|
|
target number of PGs for the whole system, look at how much data is
|
|
stored in each pool, and try to apportion PGs accordingly. The
|
|
system is relatively conservative with its approach, only making
|
|
changes to a pool when the current number of PGs (``pg_num``) is more
|
|
than a factor of 3 off from what it thinks it should be.
|
|
|
|
The target number of PGs per OSD is based on the
|
|
``mon_target_pg_per_osd`` configurable (default: 100), which can be
|
|
adjusted with::
|
|
|
|
ceph config set global mon_target_pg_per_osd 100
|
|
|
|
The autoscaler analyzes pools and adjusts on a per-subtree basis.
|
|
Because each pool may map to a different CRUSH rule, and each rule may
|
|
distribute data across different devices, Ceph will consider
|
|
utilization of each subtree of the hierarchy independently. For
|
|
example, a pool that maps to OSDs of class `ssd` and a pool that maps
|
|
to OSDs of class `hdd` will each have optimal PG counts that depend on
|
|
the number of those respective device types.
|
|
|
|
The autoscaler uses the `bulk` flag to determine which pool
|
|
should start out with a full complements of PGs and only
|
|
scales down when the the usage ratio across the pool is not even.
|
|
However, if the pool doesn't have the `bulk` flag, the pool will
|
|
start out with minimal PGs and only when there is more usage in the pool.
|
|
|
|
The autoscaler identifies any overlapping roots and prevents the pools
|
|
with such roots from scaling because overlapping roots can cause problems
|
|
with the scaling process.
|
|
|
|
To create pool with `bulk` flag::
|
|
|
|
ceph osd create <pool-name> --bulk
|
|
|
|
To set/unset `bulk` flag of existing pool::
|
|
|
|
ceph osd pool set <pool-name> bulk=true/false/1/0
|
|
|
|
To get `bulk` flag of existing pool::
|
|
|
|
ceph osd pool get <pool-name> bulk
|
|
|
|
.. _specifying_pool_target_size:
|
|
|
|
Specifying expected pool size
|
|
-----------------------------
|
|
|
|
When a cluster or pool is first created, it will consume a small
|
|
fraction of the total cluster capacity and will appear to the system
|
|
as if it should only need a small number of placement groups.
|
|
However, in most cases cluster administrators have a good idea which
|
|
pools are expected to consume most of the system capacity over time.
|
|
By providing this information to Ceph, a more appropriate number of
|
|
PGs can be used from the beginning, preventing subsequent changes in
|
|
``pg_num`` and the overhead associated with moving data around when
|
|
those adjustments are made.
|
|
|
|
The *target size* of a pool can be specified in two ways: either in
|
|
terms of the absolute size of the pool (i.e., bytes), or as a weight
|
|
relative to other pools with a ``target_size_ratio`` set.
|
|
|
|
For example::
|
|
|
|
ceph osd pool set mypool target_size_bytes 100T
|
|
|
|
will tell the system that `mypool` is expected to consume 100 TiB of
|
|
space. Alternatively::
|
|
|
|
ceph osd pool set mypool target_size_ratio 1.0
|
|
|
|
will tell the system that `mypool` is expected to consume 1.0 relative
|
|
to the other pools with ``target_size_ratio`` set. If `mypool` is the
|
|
only pool in the cluster, this means an expected use of 100% of the
|
|
total capacity. If there is a second pool with ``target_size_ratio``
|
|
1.0, both pools would expect to use 50% of the cluster capacity.
|
|
|
|
You can also set the target size of a pool at creation time with the optional ``--target-size-bytes <bytes>`` or ``--target-size-ratio <ratio>`` arguments to the ``ceph osd pool create`` command.
|
|
|
|
Note that if impossible target size values are specified (for example,
|
|
a capacity larger than the total cluster) then a health warning
|
|
(``POOL_TARGET_SIZE_BYTES_OVERCOMMITTED``) will be raised.
|
|
|
|
If both ``target_size_ratio`` and ``target_size_bytes`` are specified
|
|
for a pool, only the ratio will be considered, and a health warning
|
|
(``POOL_HAS_TARGET_SIZE_BYTES_AND_RATIO``) will be issued.
|
|
|
|
Specifying bounds on a pool's PGs
|
|
---------------------------------
|
|
|
|
It is also possible to specify a minimum number of PGs for a pool.
|
|
This is useful for establishing a lower bound on the amount of
|
|
parallelism client will see when doing IO, even when a pool is mostly
|
|
empty. Setting the lower bound prevents Ceph from reducing (or
|
|
recommending you reduce) the PG number below the configured number.
|
|
|
|
You can set the minimum or maximum number of PGs for a pool with::
|
|
|
|
ceph osd pool set <pool-name> pg_num_min <num>
|
|
ceph osd pool set <pool-name> pg_num_max <num>
|
|
|
|
You can also specify the minimum or maximum PG count at pool creation
|
|
time with the optional ``--pg-num-min <num>`` or ``--pg-num-max
|
|
<num>`` arguments to the ``ceph osd pool create`` command.
|
|
|
|
.. _preselection:
|
|
|
|
A preselection of pg_num
|
|
========================
|
|
|
|
When creating a new pool with::
|
|
|
|
ceph osd pool create {pool-name} [pg_num]
|
|
|
|
it is optional to choose the value of ``pg_num``. If you do not
|
|
specify ``pg_num``, the cluster can (by default) automatically tune it
|
|
for you based on how much data is stored in the pool (see above, :ref:`pg-autoscaler`).
|
|
|
|
Alternatively, ``pg_num`` can be explicitly provided. However,
|
|
whether you specify a ``pg_num`` value or not does not affect whether
|
|
the value is automatically tuned by the cluster after the fact. To
|
|
enable or disable auto-tuning::
|
|
|
|
ceph osd pool set {pool-name} pg_autoscale_mode (on|off|warn)
|
|
|
|
The "rule of thumb" for PGs per OSD has traditionally be 100. With
|
|
the additional of the balancer (which is also enabled by default), a
|
|
value of more like 50 PGs per OSD is probably reasonable. The
|
|
challenge (which the autoscaler normally does for you), is to:
|
|
|
|
- have the PGs per pool proportional to the data in the pool, and
|
|
- end up with 50-100 PGs per OSDs, after the replication or
|
|
erasuring-coding fan-out of each PG across OSDs is taken into
|
|
consideration
|
|
|
|
How are Placement Groups used ?
|
|
===============================
|
|
|
|
A placement group (PG) aggregates objects within a pool because
|
|
tracking object placement and object metadata on a per-object basis is
|
|
computationally expensive--i.e., a system with millions of objects
|
|
cannot realistically track placement on a per-object basis.
|
|
|
|
.. ditaa::
|
|
/-----\ /-----\ /-----\ /-----\ /-----\
|
|
| obj | | obj | | obj | | obj | | obj |
|
|
\-----/ \-----/ \-----/ \-----/ \-----/
|
|
| | | | |
|
|
+--------+--------+ +---+----+
|
|
| |
|
|
v v
|
|
+-----------------------+ +-----------------------+
|
|
| Placement Group #1 | | Placement Group #2 |
|
|
| | | |
|
|
+-----------------------+ +-----------------------+
|
|
| |
|
|
+------------------------------+
|
|
|
|
|
v
|
|
+-----------------------+
|
|
| Pool |
|
|
| |
|
|
+-----------------------+
|
|
|
|
The Ceph client will calculate which placement group an object should
|
|
be in. It does this by hashing the object ID and applying an operation
|
|
based on the number of PGs in the defined pool and the ID of the pool.
|
|
See `Mapping PGs to OSDs`_ for details.
|
|
|
|
The object's contents within a placement group are stored in a set of
|
|
OSDs. For instance, in a replicated pool of size two, each placement
|
|
group will store objects on two OSDs, as shown below.
|
|
|
|
.. ditaa::
|
|
+-----------------------+ +-----------------------+
|
|
| Placement Group #1 | | Placement Group #2 |
|
|
| | | |
|
|
+-----------------------+ +-----------------------+
|
|
| | | |
|
|
v v v v
|
|
/----------\ /----------\ /----------\ /----------\
|
|
| | | | | | | |
|
|
| OSD #1 | | OSD #2 | | OSD #2 | | OSD #3 |
|
|
| | | | | | | |
|
|
\----------/ \----------/ \----------/ \----------/
|
|
|
|
|
|
Should OSD #2 fail, another will be assigned to Placement Group #1 and
|
|
will be filled with copies of all objects in OSD #1. If the pool size
|
|
is changed from two to three, an additional OSD will be assigned to
|
|
the placement group and will receive copies of all objects in the
|
|
placement group.
|
|
|
|
Placement groups do not own the OSD; they share it with other
|
|
placement groups from the same pool or even other pools. If OSD #2
|
|
fails, the Placement Group #2 will also have to restore copies of
|
|
objects, using OSD #3.
|
|
|
|
When the number of placement groups increases, the new placement
|
|
groups will be assigned OSDs. The result of the CRUSH function will
|
|
also change and some objects from the former placement groups will be
|
|
copied over to the new Placement Groups and removed from the old ones.
|
|
|
|
Placement Groups Tradeoffs
|
|
==========================
|
|
|
|
Data durability and even distribution among all OSDs call for more
|
|
placement groups but their number should be reduced to the minimum to
|
|
save CPU and memory.
|
|
|
|
.. _data durability:
|
|
|
|
Data durability
|
|
---------------
|
|
|
|
After an OSD fails, the risk of data loss increases until the data it
|
|
contained is fully recovered. Let's imagine a scenario that causes
|
|
permanent data loss in a single placement group:
|
|
|
|
- The OSD fails and all copies of the object it contains are lost.
|
|
For all objects within the placement group the number of replica
|
|
suddenly drops from three to two.
|
|
|
|
- Ceph starts recovery for this placement group by choosing a new OSD
|
|
to re-create the third copy of all objects.
|
|
|
|
- Another OSD, within the same placement group, fails before the new
|
|
OSD is fully populated with the third copy. Some objects will then
|
|
only have one surviving copies.
|
|
|
|
- Ceph picks yet another OSD and keeps copying objects to restore the
|
|
desired number of copies.
|
|
|
|
- A third OSD, within the same placement group, fails before recovery
|
|
is complete. If this OSD contained the only remaining copy of an
|
|
object, it is permanently lost.
|
|
|
|
In a cluster containing 10 OSDs with 512 placement groups in a three
|
|
replica pool, CRUSH will give each placement groups three OSDs. In the
|
|
end, each OSDs will end up hosting (512 * 3) / 10 = ~150 Placement
|
|
Groups. When the first OSD fails, the above scenario will therefore
|
|
start recovery for all 150 placement groups at the same time.
|
|
|
|
The 150 placement groups being recovered are likely to be
|
|
homogeneously spread over the 9 remaining OSDs. Each remaining OSD is
|
|
therefore likely to send copies of objects to all others and also
|
|
receive some new objects to be stored because they became part of a
|
|
new placement group.
|
|
|
|
The amount of time it takes for this recovery to complete entirely
|
|
depends on the architecture of the Ceph cluster. Let say each OSD is
|
|
hosted by a 1TB SSD on a single machine and all of them are connected
|
|
to a 10Gb/s switch and the recovery for a single OSD completes within
|
|
M minutes. If there are two OSDs per machine using spinners with no
|
|
SSD journal and a 1Gb/s switch, it will at least be an order of
|
|
magnitude slower.
|
|
|
|
In a cluster of this size, the number of placement groups has almost
|
|
no influence on data durability. It could be 128 or 8192 and the
|
|
recovery would not be slower or faster.
|
|
|
|
However, growing the same Ceph cluster to 20 OSDs instead of 10 OSDs
|
|
is likely to speed up recovery and therefore improve data durability
|
|
significantly. Each OSD now participates in only ~75 placement groups
|
|
instead of ~150 when there were only 10 OSDs and it will still require
|
|
all 19 remaining OSDs to perform the same amount of object copies in
|
|
order to recover. But where 10 OSDs had to copy approximately 100GB
|
|
each, they now have to copy 50GB each instead. If the network was the
|
|
bottleneck, recovery will happen twice as fast. In other words,
|
|
recovery goes faster when the number of OSDs increases.
|
|
|
|
If this cluster grows to 40 OSDs, each of them will only host ~35
|
|
placement groups. If an OSD dies, recovery will keep going faster
|
|
unless it is blocked by another bottleneck. However, if this cluster
|
|
grows to 200 OSDs, each of them will only host ~7 placement groups. If
|
|
an OSD dies, recovery will happen between at most of ~21 (7 * 3) OSDs
|
|
in these placement groups: recovery will take longer than when there
|
|
were 40 OSDs, meaning the number of placement groups should be
|
|
increased.
|
|
|
|
No matter how short the recovery time is, there is a chance for a
|
|
second OSD to fail while it is in progress. In the 10 OSDs cluster
|
|
described above, if any of them fail, then ~17 placement groups
|
|
(i.e. ~150 / 9 placement groups being recovered) will only have one
|
|
surviving copy. And if any of the 8 remaining OSD fail, the last
|
|
objects of two placement groups are likely to be lost (i.e. ~17 / 8
|
|
placement groups with only one remaining copy being recovered).
|
|
|
|
When the size of the cluster grows to 20 OSDs, the number of Placement
|
|
Groups damaged by the loss of three OSDs drops. The second OSD lost
|
|
will degrade ~4 (i.e. ~75 / 19 placement groups being recovered)
|
|
instead of ~17 and the third OSD lost will only lose data if it is one
|
|
of the four OSDs containing the surviving copy. In other words, if the
|
|
probability of losing one OSD is 0.0001% during the recovery time
|
|
frame, it goes from 17 * 10 * 0.0001% in the cluster with 10 OSDs to 4 * 20 *
|
|
0.0001% in the cluster with 20 OSDs.
|
|
|
|
In a nutshell, more OSDs mean faster recovery and a lower risk of
|
|
cascading failures leading to the permanent loss of a Placement
|
|
Group. Having 512 or 4096 Placement Groups is roughly equivalent in a
|
|
cluster with less than 50 OSDs as far as data durability is concerned.
|
|
|
|
Note: It may take a long time for a new OSD added to the cluster to be
|
|
populated with placement groups that were assigned to it. However
|
|
there is no degradation of any object and it has no impact on the
|
|
durability of the data contained in the Cluster.
|
|
|
|
.. _object distribution:
|
|
|
|
Object distribution within a pool
|
|
---------------------------------
|
|
|
|
Ideally objects are evenly distributed in each placement group. Since
|
|
CRUSH computes the placement group for each object, but does not
|
|
actually know how much data is stored in each OSD within this
|
|
placement group, the ratio between the number of placement groups and
|
|
the number of OSDs may influence the distribution of the data
|
|
significantly.
|
|
|
|
For instance, if there was a single placement group for ten OSDs in a
|
|
three replica pool, only three OSD would be used because CRUSH would
|
|
have no other choice. When more placement groups are available,
|
|
objects are more likely to be evenly spread among them. CRUSH also
|
|
makes every effort to evenly spread OSDs among all existing Placement
|
|
Groups.
|
|
|
|
As long as there are one or two orders of magnitude more Placement
|
|
Groups than OSDs, the distribution should be even. For instance, 256
|
|
placement groups for 3 OSDs, 512 or 1024 placement groups for 10 OSDs
|
|
etc.
|
|
|
|
Uneven data distribution can be caused by factors other than the ratio
|
|
between OSDs and placement groups. Since CRUSH does not take into
|
|
account the size of the objects, a few very large objects may create
|
|
an imbalance. Let say one million 4K objects totaling 4GB are evenly
|
|
spread among 1024 placement groups on 10 OSDs. They will use 4GB / 10
|
|
= 400MB on each OSD. If one 400MB object is added to the pool, the
|
|
three OSDs supporting the placement group in which the object has been
|
|
placed will be filled with 400MB + 400MB = 800MB while the seven
|
|
others will remain occupied with only 400MB.
|
|
|
|
.. _resource usage:
|
|
|
|
Memory, CPU and network usage
|
|
-----------------------------
|
|
|
|
For each placement group, OSDs and MONs need memory, network and CPU
|
|
at all times and even more during recovery. Sharing this overhead by
|
|
clustering objects within a placement group is one of the main reasons
|
|
they exist.
|
|
|
|
Minimizing the number of placement groups saves significant amounts of
|
|
resources.
|
|
|
|
.. _choosing-number-of-placement-groups:
|
|
|
|
Choosing the number of Placement Groups
|
|
=======================================
|
|
|
|
.. note: It is rarely necessary to do this math by hand. Instead, use the ``ceph osd pool autoscale-status`` command in combination with the ``target_size_bytes`` or ``target_size_ratio`` pool properties. See :ref:`pg-autoscaler` for more information.
|
|
|
|
If you have more than 50 OSDs, we recommend approximately 50-100
|
|
placement groups per OSD to balance out resource usage, data
|
|
durability and distribution. If you have less than 50 OSDs, choosing
|
|
among the `preselection`_ above is best. For a single pool of objects,
|
|
you can use the following formula to get a baseline
|
|
|
|
Total PGs = :math:`\frac{OSDs \times 100}{pool \: size}`
|
|
|
|
Where **pool size** is either the number of replicas for replicated
|
|
pools or the K+M sum for erasure coded pools (as returned by **ceph
|
|
osd erasure-code-profile get**).
|
|
|
|
You should then check if the result makes sense with the way you
|
|
designed your Ceph cluster to maximize `data durability`_,
|
|
`object distribution`_ and minimize `resource usage`_.
|
|
|
|
The result should always be **rounded up to the nearest power of two**.
|
|
|
|
Only a power of two will evenly balance the number of objects among
|
|
placement groups. Other values will result in an uneven distribution of
|
|
data across your OSDs. Their use should be limited to incrementally
|
|
stepping from one power of two to another.
|
|
|
|
As an example, for a cluster with 200 OSDs and a pool size of 3
|
|
replicas, you would estimate your number of PGs as follows
|
|
|
|
:math:`\frac{200 \times 100}{3} = 6667`. Nearest power of 2: 8192
|
|
|
|
When using multiple data pools for storing objects, you need to ensure
|
|
that you balance the number of placement groups per pool with the
|
|
number of placement groups per OSD so that you arrive at a reasonable
|
|
total number of placement groups that provides reasonably low variance
|
|
per OSD without taxing system resources or making the peering process
|
|
too slow.
|
|
|
|
For instance a cluster of 10 pools each with 512 placement groups on
|
|
ten OSDs is a total of 5,120 placement groups spread over ten OSDs,
|
|
that is 512 placement groups per OSD. That does not use too many
|
|
resources. However, if 1,000 pools were created with 512 placement
|
|
groups each, the OSDs will handle ~50,000 placement groups each and it
|
|
would require significantly more resources and time for peering.
|
|
|
|
You may find the `PGCalc`_ tool helpful.
|
|
|
|
|
|
.. _setting the number of placement groups:
|
|
|
|
Set the Number of Placement Groups
|
|
==================================
|
|
|
|
To set the number of placement groups in a pool, you must specify the
|
|
number of placement groups at the time you create the pool.
|
|
See `Create a Pool`_ for details. Even after a pool is created you can also change the number of placement groups with::
|
|
|
|
ceph osd pool set {pool-name} pg_num {pg_num}
|
|
|
|
After you increase the number of placement groups, you must also
|
|
increase the number of placement groups for placement (``pgp_num``)
|
|
before your cluster will rebalance. The ``pgp_num`` will be the number of
|
|
placement groups that will be considered for placement by the CRUSH
|
|
algorithm. Increasing ``pg_num`` splits the placement groups but data
|
|
will not be migrated to the newer placement groups until placement
|
|
groups for placement, ie. ``pgp_num`` is increased. The ``pgp_num``
|
|
should be equal to the ``pg_num``. To increase the number of
|
|
placement groups for placement, execute the following::
|
|
|
|
ceph osd pool set {pool-name} pgp_num {pgp_num}
|
|
|
|
When decreasing the number of PGs, ``pgp_num`` is adjusted
|
|
automatically for you.
|
|
|
|
Get the Number of Placement Groups
|
|
==================================
|
|
|
|
To get the number of placement groups in a pool, execute the following::
|
|
|
|
ceph osd pool get {pool-name} pg_num
|
|
|
|
|
|
Get a Cluster's PG Statistics
|
|
=============================
|
|
|
|
To get the statistics for the placement groups in your cluster, execute the following::
|
|
|
|
ceph pg dump [--format {format}]
|
|
|
|
Valid formats are ``plain`` (default) and ``json``.
|
|
|
|
|
|
Get Statistics for Stuck PGs
|
|
============================
|
|
|
|
To get the statistics for all placement groups stuck in a specified state,
|
|
execute the following::
|
|
|
|
ceph pg dump_stuck inactive|unclean|stale|undersized|degraded [--format <format>] [-t|--threshold <seconds>]
|
|
|
|
**Inactive** Placement groups cannot process reads or writes because they are waiting for an OSD
|
|
with the most up-to-date data to come up and in.
|
|
|
|
**Unclean** Placement groups contain objects that are not replicated the desired number
|
|
of times. They should be recovering.
|
|
|
|
**Stale** Placement groups are in an unknown state - the OSDs that host them have not
|
|
reported to the monitor cluster in a while (configured by ``mon_osd_report_timeout``).
|
|
|
|
Valid formats are ``plain`` (default) and ``json``. The threshold defines the minimum number
|
|
of seconds the placement group is stuck before including it in the returned statistics
|
|
(default 300 seconds).
|
|
|
|
|
|
Get a PG Map
|
|
============
|
|
|
|
To get the placement group map for a particular placement group, execute the following::
|
|
|
|
ceph pg map {pg-id}
|
|
|
|
For example::
|
|
|
|
ceph pg map 1.6c
|
|
|
|
Ceph will return the placement group map, the placement group, and the OSD status::
|
|
|
|
osdmap e13 pg 1.6c (1.6c) -> up [1,0] acting [1,0]
|
|
|
|
|
|
Get a PGs Statistics
|
|
====================
|
|
|
|
To retrieve statistics for a particular placement group, execute the following::
|
|
|
|
ceph pg {pg-id} query
|
|
|
|
|
|
Scrub a Placement Group
|
|
=======================
|
|
|
|
To scrub a placement group, execute the following::
|
|
|
|
ceph pg scrub {pg-id}
|
|
|
|
Ceph checks the primary and any replica nodes, generates a catalog of all objects
|
|
in the placement group and compares them to ensure that no objects are missing
|
|
or mismatched, and their contents are consistent. Assuming the replicas all
|
|
match, a final semantic sweep ensures that all of the snapshot-related object
|
|
metadata is consistent. Errors are reported via logs.
|
|
|
|
To scrub all placement groups from a specific pool, execute the following::
|
|
|
|
ceph osd pool scrub {pool-name}
|
|
|
|
Prioritize backfill/recovery of a Placement Group(s)
|
|
====================================================
|
|
|
|
You may run into a situation where a bunch of placement groups will require
|
|
recovery and/or backfill, and some particular groups hold data more important
|
|
than others (for example, those PGs may hold data for images used by running
|
|
machines and other PGs may be used by inactive machines/less relevant data).
|
|
In that case, you may want to prioritize recovery of those groups so
|
|
performance and/or availability of data stored on those groups is restored
|
|
earlier. To do this (mark particular placement group(s) as prioritized during
|
|
backfill or recovery), execute the following::
|
|
|
|
ceph pg force-recovery {pg-id} [{pg-id #2}] [{pg-id #3} ...]
|
|
ceph pg force-backfill {pg-id} [{pg-id #2}] [{pg-id #3} ...]
|
|
|
|
This will cause Ceph to perform recovery or backfill on specified placement
|
|
groups first, before other placement groups. This does not interrupt currently
|
|
ongoing backfills or recovery, but causes specified PGs to be processed
|
|
as soon as possible. If you change your mind or prioritize wrong groups,
|
|
use::
|
|
|
|
ceph pg cancel-force-recovery {pg-id} [{pg-id #2}] [{pg-id #3} ...]
|
|
ceph pg cancel-force-backfill {pg-id} [{pg-id #2}] [{pg-id #3} ...]
|
|
|
|
This will remove "force" flag from those PGs and they will be processed
|
|
in default order. Again, this doesn't affect currently processed placement
|
|
group, only those that are still queued.
|
|
|
|
The "force" flag is cleared automatically after recovery or backfill of group
|
|
is done.
|
|
|
|
Similarly, you may use the following commands to force Ceph to perform recovery
|
|
or backfill on all placement groups from a specified pool first::
|
|
|
|
ceph osd pool force-recovery {pool-name}
|
|
ceph osd pool force-backfill {pool-name}
|
|
|
|
or::
|
|
|
|
ceph osd pool cancel-force-recovery {pool-name}
|
|
ceph osd pool cancel-force-backfill {pool-name}
|
|
|
|
to restore to the default recovery or backfill priority if you change your mind.
|
|
|
|
Note that these commands could possibly break the ordering of Ceph's internal
|
|
priority computations, so use them with caution!
|
|
Especially, if you have multiple pools that are currently sharing the same
|
|
underlying OSDs, and some particular pools hold data more important than others,
|
|
we recommend you use the following command to re-arrange all pools's
|
|
recovery/backfill priority in a better order::
|
|
|
|
ceph osd pool set {pool-name} recovery_priority {value}
|
|
|
|
For example, if you have 10 pools you could make the most important one priority 10,
|
|
next 9, etc. Or you could leave most pools alone and have say 3 important pools
|
|
all priority 1 or priorities 3, 2, 1 respectively.
|
|
|
|
Revert Lost
|
|
===========
|
|
|
|
If the cluster has lost one or more objects, and you have decided to
|
|
abandon the search for the lost data, you must mark the unfound objects
|
|
as ``lost``.
|
|
|
|
If all possible locations have been queried and objects are still
|
|
lost, you may have to give up on the lost objects. This is
|
|
possible given unusual combinations of failures that allow the cluster
|
|
to learn about writes that were performed before the writes themselves
|
|
are recovered.
|
|
|
|
Currently the only supported option is "revert", which will either roll back to
|
|
a previous version of the object or (if it was a new object) forget about it
|
|
entirely. To mark the "unfound" objects as "lost", execute the following::
|
|
|
|
ceph pg {pg-id} mark_unfound_lost revert|delete
|
|
|
|
.. important:: Use this feature with caution, because it may confuse
|
|
applications that expect the object(s) to exist.
|
|
|
|
|
|
.. toctree::
|
|
:hidden:
|
|
|
|
pg-states
|
|
pg-concepts
|
|
|
|
|
|