.\" Man page generated from reStructuredText. . .TH "MOUNT.CEPH" "8" "December 09, 2013" "dev" "Ceph" .SH NAME mount.ceph \- mount a ceph file system . .nr rst2man-indent-level 0 . .de1 rstReportMargin \\$1 \\n[an-margin] level \\n[rst2man-indent-level] level margin: \\n[rst2man-indent\\n[rst2man-indent-level]] - \\n[rst2man-indent0] \\n[rst2man-indent1] \\n[rst2man-indent2] .. .de1 INDENT .\" .rstReportMargin pre: . RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .\" .rstReportMargin post: .. .de UNINDENT . RE .\" indent \\n[an-margin] .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]] .nr rst2man-indent-level -1 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]] .in \\n[rst2man-indent\\n[rst2man-indent-level]]u .. . .nr rst2man-indent-level 0 . .de1 rstReportMargin \\$1 \\n[an-margin] level \\n[rst2man-indent-level] level margin: \\n[rst2man-indent\\n[rst2man-indent-level]] - \\n[rst2man-indent0] \\n[rst2man-indent1] \\n[rst2man-indent2] .. .de1 INDENT .\" .rstReportMargin pre: . RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .\" .rstReportMargin post: .. .de UNINDENT . RE .\" indent \\n[an-margin] .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]] .nr rst2man-indent-level -1 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]] .in \\n[rst2man-indent\\n[rst2man-indent-level]]u .. .SH SYNOPSIS .nf \fBmount.ceph\fP \fImonaddr1\fP[,\fImonaddr2\fP,...]:/[\fIsubdir\fP] \fIdir\fP [ \-o \fIoptions\fP ] .fi .sp .SH DESCRIPTION .sp \fBmount.ceph\fP is a simple helper for mounting the Ceph file system on a Linux host. It serves to resolve monitor hostname(s) into IP addresses and read authentication keys from disk; the Linux kernel client component does most of the real work. In fact, it is possible to mount a non\-authenticated Ceph file system without mount.ceph by specifying monitor address(es) by IP: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount \-t ceph 1.2.3.4:/ mountpoint .ft P .fi .UNINDENT .UNINDENT .sp Each monitor address monaddr takes the form host[:port]. If the port is not specified, the Ceph default of 6789 is assumed. .sp Multiple monitor addresses can be separated by commas. Only one responsible monitor is needed to successfully mount; the client will learn about all monitors from any responsive monitor. However, it is a good idea to specify more than one in case one happens to be down at the time of mount. .sp A subdirectory subdir may be specified if a subset of the file system is to be mounted. .sp Mount helper application conventions dictate that the first two options are device to be mounted and destination path. Options must be passed only after these fixed arguments. .SH OPTIONS .INDENT 0.0 .TP .B \fBwsize\fP int, max write size. Default: none (writeback uses smaller of wsize and stripe unit) .TP .B \fBrsize\fP int (bytes), max readahead, multiple of 1024, Default: 524288 (512*1024) .TP .B \fBosdtimeout\fP int (seconds), Default: 60 .TP .B \fBosdkeepalivetimeout\fP int, Default: 5 .TP .B \fBmount_timeout\fP int (seconds), Default: 60 .TP .B \fBosd_idle_ttl\fP int (seconds), Default: 60 .TP .B \fBcaps_wanted_delay_min\fP int, cap release delay, Default: 5 .TP .B \fBcaps_wanted_delay_max\fP int, cap release delay, Default: 60 .TP .B \fBcap_release_safety\fP int, Default: calculated .TP .B \fBreaddir_max_entries\fP int, Default: 1024 .TP .B \fBreaddir_max_bytes\fP int, Default: 524288 (512*1024) .TP .B \fBwrite_congestion_kb\fP int (kb), max writeback in flight. scale with available memory. Default: calculated from available memory .TP .B \fBsnapdirname\fP string, set the name of the hidden snapdir. Default: .snap .TP .B \fBname\fP RADOS user to authenticate as when using cephx. Default: guest .TP .B \fBsecret\fP secret key for use with cephx. This option is insecure because it exposes the secret on the command line. To avoid this, use the secretfile option. .TP .B \fBsecretfile\fP path to file containing the secret key to use with cephx .TP .B \fBip\fP my ip .TP .B \fBnoshare\fP create a new client instance, instead of sharing an existing instance of a client mounting the same cluster .TP .B \fBdirstat\fP funky \fIcat dirname\fP for stats, Default: off .TP .B \fBnodirstat\fP no funky \fIcat dirname\fP for stats .TP .B \fBrbytes\fP Report the recursive size of the directory contents for st_size on directories. Default: on .TP .B \fBnorbytes\fP Do not report the recursive size of the directory contents for st_size on directories. .TP .B \fBnocrc\fP no data crc on writes .TP .B \fBnoasyncreaddir\fP no dcache readdir .UNINDENT .SH EXAMPLES .sp Mount the full file system: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount.ceph monhost:/ /mnt/foo .ft P .fi .UNINDENT .UNINDENT .sp If there are multiple monitors: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount.ceph monhost1,monhost2,monhost3:/ /mnt/foo .ft P .fi .UNINDENT .UNINDENT .sp If \fBceph\-mon\fP(8) is running on a non\-standard port: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount.ceph monhost1:7000,monhost2:7000,monhost3:7000:/ /mnt/foo .ft P .fi .UNINDENT .UNINDENT .sp To mount only part of the namespace: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount.ceph monhost1:/some/small/thing /mnt/thing .ft P .fi .UNINDENT .UNINDENT .sp Assuming mount.ceph(8) is installed properly, it should be automatically invoked by mount(8) like so: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C mount \-t ceph monhost:/ /mnt/foo .ft P .fi .UNINDENT .UNINDENT .SH AVAILABILITY .sp \fBmount.ceph\fP is part of the Ceph distributed storage system. Please refer to the Ceph documentation at \fI\%http://ceph.com/docs\fP for more information. .SH SEE ALSO .sp \fBceph\-fuse\fP(8), \fBceph\fP(8) .SH COPYRIGHT 2010-2013, Inktank Storage, Inc. and contributors. Licensed under Creative Commons BY-SA .\" Generated by docutils manpage writer. .