doc: Added more glossary-compliant terms and indexing.

Signed-off-by: John Wilkins <john.wilkins@inktank.com>
This commit is contained in:
John Wilkins 2013-05-17 15:59:02 -07:00
parent 5c4b4f0f65
commit feec1b4630

View File

@ -13,22 +13,24 @@ details.
Background
==========
Monitors maintain a "master copy" of the :term:`cluster map`, which means a
client can determine the location of all monitors, OSDs, and metadata servers
just by connecting to one monitor and retrieving a current cluster map. Before
Ceph clients can read from or write to OSDs or metadata servers, they must
connect to a monitor first. With a current copy of the cluster map and the CRUSH
algorithm, a client can compute the location for any object. The ability to
compute object locations allows a client to talk directly to OSDs, which is a
very important aspect of Ceph's high scalability and performance.
Ceph Monitors maintain a "master copy" of the :term:`cluster map`, which means a
:term:`Ceph Client` can determine the location of all Ceph Monitors, Ceph OSD
Daemons, and Ceph Metadata Servers just by connecting to one Ceph Monitor and
retrieving a current cluster map. Before Ceph Clients can read from or write to
Ceph OSD Daemons or Ceph Metadata Servers, they must connect to a Ceph Monitor
first. With a current copy of the cluster map and the CRUSH algorithm, a Ceph
Client can compute the location for any object. The ability to compute object
locations allows a Ceph Client to talk directly to Ceph OSD Daemons, which is a
very important aspect of Ceph's high scalability and performance. See
`Scalability and High Availability`_ for additional details.
The primary role of the monitor is to maintain a master copy of the cluster map.
Monitors also provide authentication and logging services. Ceph monitors write
all changes in the monitor services to a single Paxos instance, and Paxos writes
the changes to a key/value store for strong consistency. Ceph monitors can query
the most recent version of the cluster map during sync operations. Ceph monitors
leverage the key/value store's snapshots and iterators (using leveldb) to
perform store-wide synchronization.
The primary role of the Ceph Monitor is to maintain a master copy of the cluster
map. Ceph Monitors also provide authentication and logging services. Ceph
Monitors write all changes in the monitor services to a single Paxos instance,
and Paxos writes the changes to a key/value store for strong consistency. Ceph
Monitors can query the most recent version of the cluster map during sync
operations. Ceph Monitors leverage the key/value store's snapshots and iterators
(using leveldb) to perform store-wide synchronization.
.. ditaa::
@ -55,7 +57,7 @@ perform store-wide synchronization.
.. deprecated:: version 0.58
In Ceph versions 0.58 and earlier, Ceph monitors use a Paxos instance for
In Ceph versions 0.58 and earlier, Ceph Monitors use a Paxos instance for
each service and store the map as a file.
.. index:: cluster map
@ -65,83 +67,90 @@ Cluster Maps
The cluster map is a composite of maps, including the monitor map, the OSD map,
the placement group map and the metadata server map. The cluster map tracks a
number of important things: which processes are ``in`` the cluster; which
processes that are ``in`` the cluster are ``up`` and running or ``down``;
whether, the placement groups are ``active`` or ``inactive``, and ``clean`` or
in some other state; and, other details that reflect the current state of the
cluster such as the total amount of storage space, and the amount of storage
used.
number of important things: which processes are ``in`` the Ceph Storage Cluster;
which processes that are ``in`` the Ceph Storage Cluster are ``up`` and running
or ``down``; whether, the placement groups are ``active`` or ``inactive``, and
``clean`` or in some other state; and, other details that reflect the current
state of the cluster such as the total amount of storage space, and the amount
of storage used.
When there is a significant change in the state of the cluster--e.g., an OSD
goes down, a placement group falls into a degraded state, etc.--the cluster map
gets updated to reflect the current state of the cluster. Additionally, the
monitor also maintains a history of the prior states of the cluster. The monitor
map, OSD map, placement group map and metadata server map each maintain a
history of their map versions. We call each version an "epoch."
When there is a significant change in the state of the cluster--e.g., a Ceph OSD
Daemon goes down, a placement group falls into a degraded state, etc.--the
cluster map gets updated to reflect the current state of the cluster.
Additionally, the Ceph Monitor also maintains a history of the prior states of
the cluster. The monitor map, OSD map, placement group map and metadata server
map each maintain a history of their map versions. We call each version an
"epoch."
When operating your cluster, keeping track of these states is an important
part of your system administration duties. See `Monitoring a Cluster`_ and
`Monitoring OSDs and PGs`_ for details.
When operating your Ceph Storage Cluster, keeping track of these states is an
important part of your system administration duties. See `Monitoring a Cluster`_
and `Monitoring OSDs and PGs`_ for additional details.
.. index:: high availability, quorum
.. index:: high availability; quorum
Monitor Quorum
--------------
Our 5-minute Quick Start provides a trivial `Ceph configuration file`_ that
Our Getting Started section provides a trivial `Ceph configuration file`_ that
provides for one monitor in the test cluster. A cluster will run fine with a
single monitor; however, **a single monitor is a single-point-of-failure**. To
ensure high availability in a production cluster, you should run Ceph with
multiple monitors so that the failure of a single monitor **WILL NOT** bring
down your entire cluster.
ensure high availability in a production Ceph Storage Cluster, you should run
Ceph with multiple monitors so that the failure of a single monitor **WILL NOT**
bring down your entire cluster.
When a cluster runs multiple monitors for high availability, Ceph monitors use
`Paxos`_ to establish consensus about the master cluster map. A consensus
requires a majority of monitors running to establish a quorum for consensus
about the cluster map (e.g., 1; 2 out of 3; 3 out of 5; 4 out of 6; etc.).
When a Ceph Storage Cluster runs multiple Ceph Monitors for high availability,
Ceph Monitors use `Paxos`_ to establish consensus about the master cluster map.
A consensus requires a majority of monitors running to establish a quorum for
consensus about the cluster map (e.g., 1; 2 out of 3; 3 out of 5; 4 out of 6;
etc.).
.. index:: monitor map, cluster map
.. index:: monitor map; cluster map; consistency
Consistency
-----------
When you add monitor settings to your Ceph configuration file, you need to be
aware of some of the architectural aspects of Ceph monitors. **Ceph imposes
aware of some of the architectural aspects of Ceph Monitors. **Ceph imposes
strict consistency requirements** for a Ceph monitor when discovering another
Ceph monitor within the cluster. Whereas, Ceph clients and other Ceph daemons
Ceph Monitor within the cluster. Whereas, Ceph Clients and other Ceph daemons
use the Ceph configuration file to discover monitors, monitors discover each
other using the monitor map (monmap), not the Ceph configuration file.
A monitor always refers to the local copy of the monmap when discovering other
monitors in the cluster. Using the monmap instead of the Ceph configuration file
avoids errors that could break the cluster (e.g., typos in ``ceph.conf`` when
specifying a monitor address or port). Since monitors use monmaps for discovery
and they share monmaps with clients and other Ceph daemons, **the monmap
provides monitors with a strict guarantee that their consensus is valid.**
A Ceph Monitor always refers to the local copy of the monmap when discovering
other Ceph Monitors in the Ceph Storage Cluster. Using the monmap instead of the
Ceph configuration file avoids errors that could break the cluster (e.g., typos
in ``ceph.conf`` when specifying a monitor address or port). Since monitors use
monmaps for discovery and they share monmaps with clients and other Ceph
daemons, **the monmap provides monitors with a strict guarantee that their
consensus is valid.**
Strict consistency also applies to updates to the monmap. As with any other
updates on the monitor, changes to the monmap always run through a distributed
consensus algorithm called `Paxos`_. The monitors must agree on each update to
the monmap, such as adding or removing a monitor, to ensure that each monitor in
the quorum has the same version of the monmap. Updates to the monmap are
incremental so that monitors have the latest agreed upon version, and a set of
previous versions. Maintaining a history enables a monitor that has an older
version of the monmap to catch up with the current state of the cluster.
updates on the Ceph Monitor, changes to the monmap always run through a
distributed consensus algorithm called `Paxos`_. The Ceph Monitors must agree on
each update to the monmap, such as adding or removing a Ceph Monitor, to ensure
that each monitor in the quorum has the same version of the monmap. Updates to
the monmap are incremental so that Ceph Monitors have the latest agreed upon
version, and a set of previous versions. Maintaining a history enables a Ceph
Monitor that has an older version of the monmap to catch up with the current
state of the Ceph Storage Cluster.
If monitors discovered each other through the Ceph configuration file instead of
through the monmap, it would introduce additional risks because the Ceph
configuration files aren't updated and distributed automatically. Monitors might
inadvertently use an older Ceph configuration file, fail to recognize a monitor,
fall out of a quorum, or develop a situation where `Paxos`_ isn't able to
determine the current state of the system accurately.
If Ceph Monitors discovered each other through the Ceph configuration file
instead of through the monmap, it would introduce additional risks because the
Ceph configuration files aren't updated and distributed automatically. Ceph
Monitors might inadvertently use an older Ceph configuration file, fail to
recognize a Ceph Monitor, fall out of a quorum, or develop a situation where
`Paxos`_ isn't able to determine the current state of the system accurately.
.. index:: bootstrapping monitors
Bootstrapping Monitors
----------------------
In most configuration and deployment cases, tools that deploy Ceph may help
bootstrap the monitors by generating a monitor map for you (e.g., ``mkcephfs``,
``ceph-deploy``, etc). A monitor requires four explicit settings:
bootstrap the Ceph Monitors by generating a monitor map for you (e.g.,
``mkcephfs``, ``ceph-deploy``, etc). A Ceph Monitor requires a few explicit
settings:
- **Filesystem ID**: The ``fsid`` is the unique identifier for your object
store. Since you can run multiple clusters on the same hardware, you must
@ -219,11 +228,11 @@ details.
Cluster ID
----------
Each Ceph cluster has a unique identifier (``fsid``). If specified, it usually
appears under the ``[global]`` section of the configuration file. Deployment
tools usually generate the ``fsid`` and store it in the monitor map, so the
value may not appear in a configuration file. The ``fsid`` makes it possible to
run daemons for multiple clusters on the same hardware.
Each Ceph Storage Cluster has a unique identifier (``fsid``). If specified, it
usually appears under the ``[global]`` section of the configuration file.
Deployment tools usually generate the ``fsid`` and store it in the monitor map,
so the value may not appear in a configuration file. The ``fsid`` makes it
possible to run daemons for multiple clusters on the same hardware.
``fsid``
@ -239,10 +248,11 @@ run daemons for multiple clusters on the same hardware.
Initial Members
---------------
We recommend running a production cluster with at least three monitors to ensure
high availability. When you run multiple monitors, you may specify the initial
monitors that must be members of the cluster in order to establish a quorum.
This may reduce the time it takes for your cluster to come online.
We recommend running a production Ceph Storage Cluster with at least three Ceph
Monitors to ensure high availability. When you run multiple monitors, you may
specify the initial monitors that must be members of the cluster in order to
establish a quorum. This may reduce the time it takes for your cluster to come
online.
.. code-block:: ini
@ -267,23 +277,24 @@ This may reduce the time it takes for your cluster to come online.
Data
----
Ceph provides a default path where monitors store data. For optimal performance
in a production cluster, we recommend running monitors on separate hosts and
drives from OSDs. Monitors do lots of ``fsync()``, which can interfere with OSD
workloads.
Ceph provides a default path where Ceph Monitors store data. For optimal
performance in a production Ceph Storage Cluster, we recommend running Ceph
Monitors on separate hosts and drives from Ceph OSD Daemons. Ceph Monitors do
lots of ``fsync()``, which can interfere with Ceph OSD Daemon workloads.
In Ceph versions 0.58 and earlier, monitors store their data in files. This
In Ceph versions 0.58 and earlier, Ceph Monitors store their data in files. This
approach allows users to inspect monitor data with common tools like ``ls``
and ``cat``. However, it doesn't provide strong consistency.
In Ceph versions 0.59 and later, monitors store their data as key/value pairs.
Monitors require `ACID`_ transactions. Using a data store prevents recovering
monitors from running corrupted versions through Paxos, and it enables multiple
modification operations in one single atomic batch, among other advantages.
In Ceph versions 0.59 and later, Ceph Monitors store their data as key/value
pairs. Ceph Monitors require `ACID`_ transactions. Using a data store prevents
recovering Ceph Monitors from running corrupted versions through Paxos, and it
enables multiple modification operations in one single atomic batch, among other
advantages.
Generally, we do not recommend changing the default data location. If you modify
the default location, we recommend that you make it uniform across monitors by
setting it in the ``[mon]`` section of the configuration file.
the default location, we recommend that you make it uniform across Ceph Monitors
by setting it in the ``[mon]`` section of the configuration file.
``mon data``
@ -293,36 +304,42 @@ setting it in the ``[mon]`` section of the configuration file.
:Default: ``/var/lib/ceph/mon/$cluster-$id``
.. index:: capacity planning
Storage Capacity
----------------
When a Ceph cluster gets close to its maximum capacity (i.e., ``mon osd full
ratio``), Ceph prevents you from writing to or reading from OSDs as a safety
measure to prevent data loss. Therefore, letting a production cluster approach
its full ratio is not a good practice, because it sacrifices high availability.
The default full ratio is ``.95``, or 95% of capacity. This a very aggressive
setting for a test cluster with a small number of OSDs.
When a Ceph Storage Cluster gets close to its maximum capacity (i.e., ``mon osd
full ratio``), Ceph prevents you from writing to or reading from Ceph OSD
Daemons as a safety measure to prevent data loss. Therefore, letting a
production Ceph Storage Cluster approach its full ratio is not a good practice,
because it sacrifices high availability. The default full ratio is ``.95``, or
95% of capacity. This a very aggressive setting for a test cluster with a small
number of OSDs.
.. tip:: When monitoring your cluster, be alert to warnings related to the
``nearfull`` ratio. This means that a failure of some OSDs could result
in a temporary service disruption if one or more OSDs fails. Consider adding
more OSDs to increase storage capacity.
A common scenario for test clusters involves a system administrator removing an
OSD from the cluster to watch the cluster rebalance; then, removing another OSD,
and so on until the cluster eventually reaches the full ratio and locks up. We
recommend a bit of capacity planning even with a test cluster so that you can
gauge how much spare capacity you will need to maintain for high availability.
Ideally, you want to plan for a series of OSD failures where the cluster can
recover to an ``active + clean`` state without replacing those OSDs immediately.
You can run a cluster in an ``active + degraded`` state, but this is not ideal
for normal operating conditions.
A common scenario for test clusters involves a system administrator removing a
Ceph OSD Daemon from the Ceph Storage Cluster to watch the cluster rebalance;
then, removing another Ceph OSD Daemon, and so on until the Ceph Storage Cluster
eventually reaches the full ratio and locks up. We recommend a bit of capacity
planning even with a test cluster. Planning enables you to gauge how much spare
capacity you will need in order to maintain high availability. Ideally, you want
to plan for a series of Ceph OSD Daemon failures where the cluster can recover
to an ``active + clean`` state without replacing those Ceph OSD Daemons
immediately. You can run a cluster in an ``active + degraded`` state, but this
is not ideal for normal operating conditions.
The following diagram depicts a simplistic Ceph cluster containing 33 hosts with
one OSD per host, each OSD having a 3TB capacity. So this exemplary cluster has
a maximum actual capacity of 99TB. With a ``mon osd full ratio`` of ``0.95``, if
the cluster falls to 5TB of remaining capacity, the cluster will not allow Ceph
clients to read and write data. So its operating capacity is 95TB, not 99TB.
The following diagram depicts a simplistic Ceph Storage Cluster containing 33
Ceph Nodes with one Ceph OSD Daemon per host, each Ceph OSD Daemon reading from
and writing to a 3TB drive. So this exemplary Ceph Storage Cluster has a maximum
actual capacity of 99TB. With a ``mon osd full ratio`` of ``0.95``, if the Ceph
Storage Cluster falls to 5TB of remaining capacity, the cluster will not allow
Ceph Clients to read and write data. So the Ceph Storage Cluster's operating
capacity is 95TB, not 99TB.
.. ditaa::
@ -397,6 +414,7 @@ a reasonable number for a near full ratio.
.. tip:: If some OSDs are nearfull, but others have plenty of capacity, you
may have a problem with the CRUSH weight for the nearfull OSDs.
.. index:: heartbeat
Heartbeat
---------
@ -406,6 +424,9 @@ receiving reports from OSDs about the status of their neighboring OSDs. Ceph
provides reasonable default settings for monitor/OSD interaction; however, you
may modify them as needed. See `Monitor/OSD Interaction`_ for details.
.. index:: monitor synchronization; leader; provider; requester
Monitor Store Synchronization
-----------------------------
@ -647,11 +668,11 @@ will not work, because there is a single Paxos instance for all services.
:Default: ``256 * 1024``
Clock
-----
``clock offset``
:Description: How much to offset the system clock. See ``Clock.cc`` for details.
@ -691,6 +712,7 @@ Clock
:Default: ``300.0``
Client
------
@ -799,4 +821,5 @@ Miscellaneous
.. _Monitoring OSDs and PGs: ../../operations/monitoring-osd-pg
.. _Bootstrapping a Monitor: ../../../dev/mon-bootstrap
.. _Changing a Monitor's IP Address: ../../operations/add-or-rm-mons#changing-a-monitor-s-ip-address
.. _Monitor/OSD Interaction: ../mon-osd-interaction
.. _Monitor/OSD Interaction: ../mon-osd-interaction
.. _Scalability and High Availability: ../../../architecture#scalability-and-high-availability