CRUSH Location
|
||||
==============
|
||||
|
||||
The location of an OSD in terms of the CRUSH map's hierarchy is referred to
|
||||
as a 'crush location'. This location specifier takes the form of a list of
|
||||
key and value pairs describing a position. For example, if an OSD is in a
|
||||
particular row, rack, and host, and is part of the 'default' CRUSH tree, its
|
||||
crush location could be described as::
|
||||
particular row, rack, chassis and host, and is part of the 'default' CRUSH
|
||||
tree, its crush location could be described as::
|
||||
|
||||
root=default row=a rack=a12 host=foohost
|
||||
root=default row=a rack=a2 chassis=a2a host=a2a1
|
||||
|
||||
Note:
|
||||
|
||||
#. Note that the order of the keys does not matter.
|
||||
#. The key name (left of ``=``) must be a valid CRUSH ``type``. By default
|
||||
these include root, datacenter, row, rack, chassis and host, but those types
|
||||
can be customized to be anything appropriate by modifying the CRUSH map.
|
||||
these include root, datacenter, room, row, pod, pdu, rack, chassis and host,
|
||||
but those types can be customized to be anything appropriate by modifying
|
||||
the CRUSH map.
|
||||
#. Not all keys need to be specified. For example, by default, Ceph
|
||||
automatically sets a ``ceph-osd`` daemon's location to be
|
||||
``root=default host=HOSTNAME`` (based on the output from ``hostname -s``).
|
||||
@ -198,7 +200,8 @@ There are four main sections to a CRUSH Map.
|
||||
|
||||
#. **Bucket Types**: Bucket ``types`` define the types of buckets used in your
|
||||
CRUSH hierarchy. Buckets consist of a hierarchical aggregation of storage
|
||||
locations (e.g., rows, racks, hosts, etc.) and their assigned weights.
|
||||
locations (e.g., rows, racks, chassis, hosts, etc.) and their assigned
|
||||
weights.
|
||||
|
||||
#. **Bucket Instances:** Once you define bucket types, you must declare bucket
|
||||
instances for your hosts, and any other failure domain partitioning
|
||||
@ -216,7 +219,8 @@ to better ensure data safety and availability.
|
||||
|
||||
.. note:: The generated CRUSH map doesn't take your larger grained failure
|
||||
domains into account. So you should modify your CRUSH map to account for
|
||||
larger grained failure domains such as racks, rows, data centers, etc.
|
||||
larger grained failure domains such as chassis, racks, rows, data
|
||||
centers, etc.
|
||||
|
||||
|
||||
|
||||
@ -274,7 +278,15 @@ For example::
|
||||
# types
|
||||
type 0 osd
|
||||
type 1 host
|
||||
type 2 rack
|
||||
type 2 chassis
|
||||
type 3 rack
|
||||
type 4 row
|
||||
type 5 pdu
|
||||
type 6 pod
|
||||
type 7 room
|
||||
type 8 datacenter
|
||||
type 9 region
|
||||
type 10 root
|
||||
|
||||
|
||||
|
||||
@ -292,9 +304,10 @@ devices and the logical elements that contain them.
|
||||
To map placement groups to OSDs across failure domains, a CRUSH map defines a
|
||||
hierarchical list of bucket types (i.e., under ``#types`` in the generated CRUSH
|
||||
map). The purpose of creating a bucket hierarchy is to segregate the
|
||||
leaf nodes by their failure domains, such as hosts, racks, rows, rooms, and data
|
||||
centers. With the exception of the leaf nodes representing OSDs, the rest of the
|
||||
hierarchy is arbitrary, and you may define it according to your own needs.
|
||||
leaf nodes by their failure domains, such as hosts, chassis, racks, power
|
||||
distribution units, pods, rows, rooms, and data centers. With the exception of
|
||||
the leaf nodes representing OSDs, the rest of the hierarchy is arbitrary, and
|
||||
you may define it according to your own needs.
|
||||
|
||||
We recommend adapting your CRUSH map to your firms's hardware naming conventions
|
||||
and using instances names that reflect the physical hardware. Your naming
|
||||
@ -328,12 +341,15 @@ and two node buckets named ``host`` and ``rack`` respectively.
|
||||
.. note:: The higher numbered ``rack`` bucket type aggregates the lower
|
||||
numbered ``host`` bucket type.
|
||||
|
||||
Since leaf nodes reflect storage devices declared under the ``#devices`` list at
|
||||
the beginning of the CRUSH map, you do not need to declare them as bucket
|
||||
Since leaf nodes reflect storage devices declared under the ``#devices`` list
|
||||
at the beginning of the CRUSH map, you do not need to declare them as bucket
|
||||
instances. The second lowest bucket type in your hierarchy usually aggregates
|
||||
the devices (i.e., it's usually the computer containing the storage media, and
|
||||
uses whatever term you prefer to describe it, such as "node", "computer",
|
||||
"server," "host", "machine", etc.).
|
||||
"server," "host", "machine", etc.). In high density environments, it is
|
||||
increasingly common to see multiple hosts/nodes per chassis. You should account
|
||||
for chassis failure too--e.g., the need to pull a chassis if a node fails may
|
||||
result in bringing down numerous hosts/nodes and their OSDs.
|
||||
|
||||
When declaring a bucket instance, you must specify its type, give it a unique
|
||||
name (string), assign it a unique ID expressed as a negative integer (optional),
|
||||
|