doc/rados/troubleshooting: description of upgrade procedure - stopping/starting OSDs
Fixes: https://tracker.ceph.com/issues/14730 Signed-off-by: Anthony D'Atri <anthony.datri@gmail.com>
This commit is contained in:
parent
1464a7d588
commit
84757fc202
@ -12,8 +12,6 @@ are running properly, because networks may have a significant impact on OSD
|
||||
operation and performance. Look for dropped packets on the host side
|
||||
and CRC errors on the switch side.
|
||||
|
||||
|
||||
|
||||
Obtaining Data About OSDs
|
||||
=========================
|
||||
|
||||
@ -60,7 +58,6 @@ The admin socket, among other things, allows you to:
|
||||
- Dump operations in flight
|
||||
- Dump perfcounters
|
||||
|
||||
|
||||
Display Freespace
|
||||
-----------------
|
||||
|
||||
@ -71,7 +68,6 @@ Filesystem issues may arise. To display your file system's free space, execute
|
||||
|
||||
Execute ``df --help`` for additional usage.
|
||||
|
||||
|
||||
I/O Statistics
|
||||
--------------
|
||||
|
||||
@ -79,7 +75,6 @@ Use `iostat`_ to identify I/O-related issues. ::
|
||||
|
||||
iostat -x
|
||||
|
||||
|
||||
Diagnostic Messages
|
||||
-------------------
|
||||
|
||||
@ -88,7 +83,6 @@ or ``tail``. For example::
|
||||
|
||||
dmesg | grep scsi
|
||||
|
||||
|
||||
Stopping w/out Rebalancing
|
||||
==========================
|
||||
|
||||
@ -110,24 +104,28 @@ Or an entire CRUSH bucket at a time. Say you're going to take down
|
||||
|
||||
ceph osd set-group noout prod-ceph-data1701
|
||||
|
||||
Once the flag is set you can begin stopping the OSDs within the
|
||||
failure domain that requires maintenance work. ::
|
||||
Once the flag is set you can stop the OSDs and any other colocated Ceph
|
||||
services within the failure domain that requires maintenance work. ::
|
||||
|
||||
stop ceph-osd id={num}
|
||||
systemctl stop ceph\*.service ceph\*.target
|
||||
|
||||
.. note:: Placement groups within the OSDs you stop will become ``degraded``
|
||||
while you are addressing issues with within the failure domain.
|
||||
|
||||
Once you have completed your maintenance, restart the OSDs. ::
|
||||
Once you have completed your maintenance, restart the OSDs and any other
|
||||
daemons. If you rebooted the host as part of the maintenance, these should
|
||||
come back on their own without intervention. ::
|
||||
|
||||
start ceph-osd id={num}
|
||||
sudo systemctl start ceph.target
|
||||
|
||||
Finally, you must unset the cluster from ``noout``. ::
|
||||
Finally, you must unset the cluster-wide``noout`` flag::
|
||||
|
||||
ceph osd unset noout
|
||||
ceph osd unset-group noout prod-ceph-data1701
|
||||
|
||||
|
||||
Note that most Linux distributions that Ceph supports today employ ``systemd``
|
||||
for service management. For other or older operating systems you may need
|
||||
to issue equivalent ``service`` or ``start``/``stop`` commands.
|
||||
|
||||
.. _osd-not-running:
|
||||
|
||||
@ -184,7 +182,6 @@ If you start your cluster and an OSD won't start, check the following:
|
||||
may activate connection tracking anyway, so a "set and forget" strategy for
|
||||
the tunables is advised. On modern systems this will not consume appreciable
|
||||
resources.
|
||||
|
||||
|
||||
- **Kernel Version:** Identify the kernel version and distribution you
|
||||
are using. Ceph uses some third party tools by default, which may be
|
||||
@ -202,7 +199,6 @@ If you start your cluster and an OSD won't start, check the following:
|
||||
release being run, ``ceph.conf`` (with secrets XXX'd out),
|
||||
your monitor status output and excerpts from your log file(s).
|
||||
|
||||
|
||||
An OSD Failed
|
||||
-------------
|
||||
|
||||
@ -224,7 +220,6 @@ or ::
|
||||
|
||||
ceph osd tree down
|
||||
|
||||
|
||||
If there is a drive
|
||||
failure or other fault preventing ``ceph-osd`` from functioning or
|
||||
restarting, an error message should be present in its log file under
|
||||
@ -241,7 +236,6 @@ unexpected error), search the archives and tracker as above, and
|
||||
report it to the `ceph-devel`_ email list if there's no clear fix or
|
||||
existing bug.
|
||||
|
||||
|
||||
No Free Drive Space
|
||||
-------------------
|
||||
|
||||
@ -317,11 +311,10 @@ some space deleting a few placement group directories in the full OSD.
|
||||
|
||||
See `Monitor Config Reference`_ for additional details.
|
||||
|
||||
|
||||
OSDs are Slow/Unresponsive
|
||||
==========================
|
||||
|
||||
A commonly recurring issue involves slow or unresponsive OSDs. Ensure that you
|
||||
A common issue involves slow or unresponsive OSDs. Ensure that you
|
||||
have eliminated other troubleshooting possibilities before delving into OSD
|
||||
performance issues. For example, ensure that your network(s) is working properly
|
||||
and your OSDs are running. Check to see if OSDs are throttling recovery traffic.
|
||||
@ -330,7 +323,6 @@ and your OSDs are running. Check to see if OSDs are throttling recovery traffic.
|
||||
recovering OSDs from using up system resources so that ``up`` and ``in``
|
||||
OSDs are not available or are otherwise slow.
|
||||
|
||||
|
||||
Networking Issues
|
||||
-----------------
|
||||
|
||||
@ -350,7 +342,6 @@ Check network statistics. ::
|
||||
|
||||
netstat -s
|
||||
|
||||
|
||||
Drive Configuration
|
||||
-------------------
|
||||
|
||||
@ -370,7 +361,6 @@ we recommend against using ``Btrfs`` for production deployments.)
|
||||
sequential read/write limits. Running a journal in a separate partition
|
||||
may help, but you should prefer a separate physical drive.
|
||||
|
||||
|
||||
Bad Sectors / Fragmented Disk
|
||||
-----------------------------
|
||||
|
||||
@ -378,7 +368,6 @@ Check your drives for bad blocks, fragmentation, and other errors that can cause
|
||||
performance to drop substantially. Invaluable tools include ``dmesg``, ``syslog``
|
||||
logs, and ``smartctl`` (from the ``smartmontools`` package).
|
||||
|
||||
|
||||
Co-resident Monitors/OSDs
|
||||
-------------------------
|
||||
|
||||
@ -394,7 +383,6 @@ OSDs, you may incur performance issues related to:
|
||||
In these cases, multiple OSDs running on the same host can drag each other down
|
||||
by doing lots of commits. That often leads to the bursty writes.
|
||||
|
||||
|
||||
Co-resident Processes
|
||||
---------------------
|
||||
|
||||
@ -405,7 +393,6 @@ recommend optimizing hosts for use with Ceph and using other hosts for other
|
||||
processes. The practice of separating Ceph operations from other applications
|
||||
may help improve performance and may streamline troubleshooting and maintenance.
|
||||
|
||||
|
||||
Logging Levels
|
||||
--------------
|
||||
|
||||
@ -414,7 +401,6 @@ logging levels back down, the OSD may be putting a lot of logs onto the disk. If
|
||||
you intend to keep logging levels high, you may consider mounting a drive to the
|
||||
default path for logging (i.e., ``/var/log/ceph/$cluster-$name.log``).
|
||||
|
||||
|
||||
Recovery Throttling
|
||||
-------------------
|
||||
|
||||
@ -422,21 +408,18 @@ Depending upon your configuration, Ceph may reduce recovery rates to maintain
|
||||
performance or it may increase recovery rates to the point that recovery
|
||||
impacts OSD performance. Check to see if the OSD is recovering.
|
||||
|
||||
|
||||
Kernel Version
|
||||
--------------
|
||||
|
||||
Check the kernel version you are running. Older kernels may not receive
|
||||
new backports that Ceph depends upon for better performance.
|
||||
|
||||
|
||||
Kernel Issues with SyncFS
|
||||
-------------------------
|
||||
|
||||
Try running one OSD per host to see if performance improves. Old kernels
|
||||
might not have a recent enough version of ``glibc`` to support ``syncfs(2)``.
|
||||
|
||||
|
||||
Filesystem Issues
|
||||
-----------------
|
||||
|
||||
@ -454,7 +437,6 @@ For more information, see `Filesystem Recommendations`_.
|
||||
|
||||
.. _Filesystem Recommendations: ../configuration/filesystem-recommendations
|
||||
|
||||
|
||||
Insufficient RAM
|
||||
----------------
|
||||
|
||||
@ -467,7 +449,6 @@ when OSDs experience recovery their memory utilization spikes. If
|
||||
there is insufficient RAM available, OSD performance will slow considerably
|
||||
and the daemons may even crash or be killed by the Linux ``OOM Killer``.
|
||||
|
||||
|
||||
Blocked Requests or Slow Requests
|
||||
---------------------------------
|
||||
|
||||
@ -485,7 +466,6 @@ New versions of Ceph complain about ``slow requests``::
|
||||
{date} {osd.num} [WRN] 1 slow requests, 1 included below; oldest blocked for > 30.005692 secs
|
||||
{date} {osd.num} [WRN] slow request 30.005692 seconds old, received at {date-time}: osd_op(client.4240.0:8 benchmark_data_ceph-1_39426_object7 [write 0~4194304] 0.69848840) v4 currently waiting for subops from [610]
|
||||
|
||||
|
||||
Possible causes include:
|
||||
|
||||
- A failing drive (check ``dmesg`` output)
|
||||
|