2023-03-10 23:39:51 +00:00
|
|
|
.. _read_balancer:
|
|
|
|
|
|
|
|
=======================================
|
|
|
|
Operating the Read (Primary) Balancer
|
|
|
|
=======================================
|
|
|
|
|
|
|
|
You might be wondering: How can I improve performance in my Ceph cluster?
|
|
|
|
One important data point you can check is the ``read_balance_score`` on each
|
|
|
|
of your replicated pools.
|
|
|
|
|
|
|
|
This metric, available via ``ceph osd pool ls detail`` (see :ref:`rados_pools`
|
|
|
|
for more details) indicates read performance, or how balanced the primaries are
|
|
|
|
for each replicated pool. In most cases, if a ``read_balance_score`` is above 1
|
|
|
|
(for instance, 1.5), this means that your pool has unbalanced primaries and that
|
|
|
|
you may want to try improving your read performance with the read balancer.
|
|
|
|
|
|
|
|
Online Optimization
|
|
|
|
===================
|
|
|
|
|
2024-01-18 18:57:24 +00:00
|
|
|
Enabling
|
|
|
|
--------
|
|
|
|
|
|
|
|
To enable automatic read balancing, you must turn on the *balancer module*
|
|
|
|
(enabled by default in new clusters) and set the mode to ``read`` or ``upmap-read``:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
ceph balancer on
|
|
|
|
ceph balancer mode <read|upmap-read>
|
|
|
|
|
|
|
|
Both ``read`` and ``upmap-read`` mode make use of ``pg-upmap-primary``. In order
|
|
|
|
to use ``pg-upmap-primary``, the cluster cannot have any pre-Reef clients.
|
|
|
|
|
|
|
|
If you want to use a different balancer or if you want to make your
|
|
|
|
own custom ``pg-upmap-primary`` entries, you might want to turn off the balancer in
|
|
|
|
order to avoid conflict:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
ceph balancer off
|
|
|
|
|
|
|
|
To allow use of the new feature on an existing cluster, you must restrict the
|
|
|
|
cluster to supporting only Reef (and newer) clients. To do so, run the
|
|
|
|
following command:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
ceph osd set-require-min-compat-client reef
|
|
|
|
|
|
|
|
This command will fail if any pre-Reef clients or daemons are connected to
|
|
|
|
the monitors. To see which client versions are in use, run the following
|
|
|
|
command:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
ceph features
|
|
|
|
|
|
|
|
Balancer Module
|
|
|
|
---------------
|
|
|
|
|
|
|
|
The `balancer` module for ``ceph-mgr`` will automatically balance the number of
|
|
|
|
primary PGs per OSD if set to ``read`` or ``upmap-read`` mode. See :ref:`balancer`
|
|
|
|
for more information.
|
2023-03-10 23:39:51 +00:00
|
|
|
|
|
|
|
Offline Optimization
|
|
|
|
====================
|
|
|
|
|
|
|
|
Primaries are updated with an offline optimizer that is built into the
|
|
|
|
:ref:`osdmaptool`.
|
|
|
|
|
|
|
|
#. Grab the latest copy of your osdmap:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
ceph osd getmap -o om
|
|
|
|
|
|
|
|
#. Run the optimizer:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
osdmaptool om --read out.txt --read-pool <pool name> [--vstart]
|
|
|
|
|
|
|
|
It is highly recommended that you run the capacity balancer before running the
|
|
|
|
balancer to ensure optimal results. See :ref:`upmap` for details on how to balance
|
|
|
|
capacity in a cluster.
|
|
|
|
|
|
|
|
#. Apply the changes:
|
|
|
|
|
|
|
|
.. prompt:: bash $
|
|
|
|
|
|
|
|
source out.txt
|
|
|
|
|
|
|
|
In the above example, the proposed changes are written to the output file
|
|
|
|
``out.txt``. The commands in this procedure are normal Ceph CLI commands
|
|
|
|
that can be run in order to apply the changes to the cluster.
|
|
|
|
|
|
|
|
If you are working in a vstart cluster, you may pass the ``--vstart`` parameter
|
|
|
|
as shown above so the CLI commands are formatted with the `./bin/` prefix.
|
|
|
|
|
|
|
|
Note that any time the number of pgs changes (for instance, if the pg autoscaler [:ref:`pg-autoscaler`]
|
|
|
|
kicks in), you should consider rechecking the scores and rerunning the balancer if needed.
|
|
|
|
|
|
|
|
To see some details about what the tool is doing, you can pass
|
|
|
|
``--debug-osd 10`` to ``osdmaptool``. To see even more details, pass
|
|
|
|