2012-12-28 23:55:46 +00:00
|
|
|
================
|
|
|
|
Upgrading Ceph
|
|
|
|
================
|
|
|
|
|
|
|
|
You can upgrade daemons in your Ceph cluster one-by-one while the cluster is
|
|
|
|
online and in service! The upgrade process is relatively simple:
|
|
|
|
|
|
|
|
#. Login to a host and upgrade the Ceph package.
|
|
|
|
#. Restart the daemon.
|
|
|
|
#. Ensure your cluster is healthy.
|
|
|
|
|
|
|
|
.. important:: Once you upgrade a daemon, you cannot downgrade it.
|
|
|
|
|
|
|
|
Certain types of daemons depend upon others. For example, metadata servers and
|
|
|
|
RADOS gateways depend upon Ceph monitors and OSDs. We recommend upgrading
|
|
|
|
daemons in this order:
|
|
|
|
|
|
|
|
#. Monitors (or OSDs)
|
|
|
|
#. OSDs (or Monitors)
|
|
|
|
#. Metadata Servers
|
|
|
|
#. RADOS Gateway
|
|
|
|
|
|
|
|
As a general rule, we recommend upgrading all the daemons of a specific type
|
|
|
|
(e.g., all ``ceph-osd`` daemons, all ``ceph-mon`` daemons, etc.) to ensure that
|
|
|
|
they are all on the same release. We also recommend that you upgrade all the
|
2013-05-01 00:39:50 +00:00
|
|
|
daemons in your cluster before you try to exercise new functionality in a
|
2013-05-01 00:32:15 +00:00
|
|
|
release.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Release-specific Upgrade Details
|
|
|
|
================================
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Each release of Ceph may have some additional steps. Refer to the following
|
|
|
|
sections to identify release-specific procedures for your cluster before
|
2013-05-01 00:39:50 +00:00
|
|
|
using the upgrade procedures.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Upgrading from Argonaut to Bobtail
|
|
|
|
----------------------------------
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
When upgrading from Argonaut to Bobtail, you need to be aware of several things:
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
#. Authentication now defaults to **ON**, but used to default to **OFF**.
|
|
|
|
#. Monitors use a new internal on-wire protocol.
|
|
|
|
#. RBD ``format2`` images require upgrading all OSDs before using it.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Ensure that you update package repository paths. For example::
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
sudo rm /etc/apt/sources.sources.list.d/ceph.list
|
|
|
|
echo deb http://ceph.com/debian-bobtail/ $(lsb_release -sc) main | sudo tee /etc/apt/sources.list.d/ceph.list
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
See the following sections for additional details.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Authentication
|
|
|
|
~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
The Ceph Bobtail release enables authentication by default. Bobtail also has
|
|
|
|
finer-grained authentication configuration settings. In previous versions of
|
|
|
|
Ceph (i.e., actually v 0.55 and earlier), you could simply specify::
|
|
|
|
|
|
|
|
auth supported = [cephx | none]
|
|
|
|
|
|
|
|
This option still works, but is deprecated. New releases support
|
|
|
|
``cluster``, ``service`` and ``client`` authentication settings as
|
|
|
|
follows::
|
|
|
|
|
|
|
|
auth cluster required = [cephx | none] # default cephx
|
|
|
|
auth service required = [cephx | none] # default cephx
|
|
|
|
auth client required = [cephx | none] # default cephx,none
|
|
|
|
|
|
|
|
.. important:: If your cluster does not currently have an ``auth
|
|
|
|
supported`` line that enables authentication, you must explicitly
|
|
|
|
turn it off in Bobtail using the settings below.::
|
|
|
|
|
|
|
|
auth cluster required = none
|
|
|
|
auth service required = none
|
|
|
|
|
|
|
|
This will disable authentication on the cluster, but still leave
|
|
|
|
clients with the default configuration where they can talk to a
|
|
|
|
cluster that does enable it, but do not require it.
|
|
|
|
|
|
|
|
.. important:: If your cluster already has an ``auth supported`` option defined in
|
|
|
|
the configuration file, no changes are necessary.
|
|
|
|
|
|
|
|
See `Ceph Authentication - Backward Compatibility`_ for details.
|
|
|
|
|
|
|
|
|
|
|
|
Monitor On-wire Protocol
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
We recommend upgrading all monitors to Bobtail. A mixture of Bobtail and
|
|
|
|
Argonaut monitors will not be able to use the new on-wire protocol, as the
|
|
|
|
protocol requires all monitors to be Bobtail or greater. Upgrading only a
|
|
|
|
majority of the nodes (e.g., two out of three) may expose the cluster to a
|
|
|
|
situation where a single additional failure may compromise availability (because
|
|
|
|
the non-upgraded daemon cannot participate in the new protocol). We recommend
|
|
|
|
not waiting for an extended period of time between ``ceph-mon`` upgrades.
|
|
|
|
|
|
|
|
|
|
|
|
RBD Images
|
|
|
|
~~~~~~~~~~
|
|
|
|
|
|
|
|
The Bobtail release supports ``format 2`` images! However, you should not create
|
|
|
|
or use ``format 2`` RBD images until after all ``ceph-osd`` daemons have been
|
|
|
|
upgraded. Note that ``format 1`` is still the default. You can use the new
|
|
|
|
``ceph osd ls`` and ``ceph tell osd.N version`` commands to doublecheck your
|
|
|
|
cluster. ``ceph osd ls`` will give a list of all OSD IDs that are part of the
|
|
|
|
cluster, and you can use that to write a simple shell loop to display all the
|
|
|
|
OSD version strings: ::
|
|
|
|
|
|
|
|
for i in $(ceph osd ls); do
|
|
|
|
ceph tell osd.${i} version
|
|
|
|
done
|
|
|
|
|
|
|
|
|
|
|
|
Upgrading from Argonaut to Cuttlefish
|
|
|
|
-------------------------------------
|
|
|
|
|
|
|
|
To upgrade your cluster from Argonaut to Cuttlefish, please read this section,
|
|
|
|
and the sections on upgrading from Argonaut to Bobtail and upgrading from
|
|
|
|
Bobtail to Cuttlefish carefully. When upgrading from Argonaut to Cuttlefish,
|
|
|
|
**YOU MUST UPGRADE YOUR MONITORS FROM ARGONAUT TO BOBTAIL FIRST!!!**. All other
|
|
|
|
Ceph daemons can upgrade from Argonaut to Cuttlefish without the intermediate
|
|
|
|
upgrade to Bobtail.
|
|
|
|
|
|
|
|
.. important:: Ensure that the repository specified points to Bobtail, not
|
|
|
|
Cuttlefish.
|
|
|
|
|
|
|
|
For example::
|
|
|
|
|
|
|
|
sudo rm /etc/apt/sources.sources.list.d/ceph.list
|
|
|
|
echo deb http://ceph.com/debian-bobtail/ $(lsb_release -sc) main | sudo tee /etc/apt/sources.list.d/ceph.list
|
|
|
|
|
|
|
|
We recommend upgrading all monitors to Bobtail before proceeding with the
|
|
|
|
upgrade of the monitors to Cuttlefish. A mixture of Bobtail and Argonaut
|
|
|
|
monitors will not be able to use the new on-wire protocol, as the protocol
|
|
|
|
requires all monitors to be Bobtail or greater. Upgrading only a majority of the
|
|
|
|
nodes (e.g., two out of three) may expose the cluster to a situation where a
|
|
|
|
single additional failure may compromise availability (because the non-upgraded
|
|
|
|
daemon cannot participate in the new protocol). We recommend not waiting for an
|
|
|
|
extended period of time between ``ceph-mon`` upgrades. See `Upgrading a
|
|
|
|
Monitor`_ for details.
|
|
|
|
|
|
|
|
.. note:: See the `Authentication`_ section and the
|
|
|
|
`Ceph Authentication - Backward Compatibility`_ for additional information
|
|
|
|
on authentication backward compatibility settings for Bobtail.
|
|
|
|
|
|
|
|
Once you complete the upgrade of your monitors from Argonaut to Bobtail, you
|
|
|
|
must upgrade the monitors from Bobtail to Cuttlefish. Ensure that you have
|
|
|
|
a quorum before beginning this upgrade procedure. Before upgrading, remember
|
|
|
|
to replace the reference to the Bobtail repository with a reference to the
|
|
|
|
Cuttlefish repository. For example::
|
|
|
|
|
|
|
|
sudo rm /etc/apt/sources.sources.list.d/ceph.list
|
|
|
|
echo deb http://ceph.com/debian-cuttlefish/ $(lsb_release -sc) main | sudo tee /etc/apt/sources.list.d/ceph.list
|
|
|
|
|
|
|
|
See `Upgrading a Monitor`_ for details.
|
|
|
|
|
|
|
|
The architecture of the monitors changed significantly from Argonaut to
|
|
|
|
Cuttlefish. See `Monitor Config Reference`_ and `Joao's blog post`_ for details.
|
|
|
|
Once you complete the monitor upgrade, you can upgrade the OSD daemons and the
|
|
|
|
MDS daemons using the generic procedures. See `Upgrading an OSD`_ and `Upgrading
|
|
|
|
a Metadata Server`_ for details.
|
|
|
|
|
|
|
|
|
|
|
|
Upgrading from Bobtail to Cuttlefish
|
|
|
|
------------------------------------
|
|
|
|
|
|
|
|
Upgrading your cluster from Bobtail to Cuttlefish has a few important
|
|
|
|
considerations. First, the monitor uses a new architecture, so you should
|
|
|
|
upgrade the full set of monitors to use Cuttlefish. Second, ensure metadata
|
|
|
|
servers have unique names. See the following sections for details.
|
|
|
|
|
|
|
|
|
|
|
|
Monitor
|
|
|
|
~~~~~~~
|
|
|
|
|
|
|
|
The architecture of the monitors changed significantly from Bobtail to
|
|
|
|
Cuttlefish. See `Monitor Config Reference`_ and `Joao's blog post`_ for
|
|
|
|
details. This means that v0.59 and pre-v0.59 monitors do not talk to each other
|
|
|
|
(Cuttlefish is v.0.61). When you upgrade each monitor, it will convert its
|
|
|
|
local data store to the new format. Once you upgrade a majority of monitors,
|
|
|
|
the monitors form a quorum using the new protocol and the old monitors will be
|
|
|
|
blocked until they get upgraded. For this reason, we recommend upgrading the
|
|
|
|
monitors in immediate succession.
|
|
|
|
|
|
|
|
.. important:: Do not run a mixed-version cluster for an extended period.
|
|
|
|
|
|
|
|
|
|
|
|
MDS Unique Names
|
|
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
The monitor now enforces that MDS names be unique. If you have multiple daemons
|
|
|
|
start with with the same id (e.g., mds.a) the second one will implicitly mark
|
|
|
|
the first as failed. Multi-MDS configurations with identical names must be
|
|
|
|
adjusted accordingly to give daemons unique names.
|
|
|
|
|
|
|
|
|
|
|
|
Upgrade Procedures
|
|
|
|
==================
|
|
|
|
|
|
|
|
The following sections describe the upgrade process.
|
|
|
|
|
|
|
|
.. important:: Each release of Ceph may have some additional steps. Refer to
|
|
|
|
release-specific sections for details **BEFORE** you begin upgrading daemons.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
|
|
|
|
Upgrading a Monitor
|
2013-05-01 00:32:15 +00:00
|
|
|
-------------------
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
To upgrade a monitor, perform the following steps:
|
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
#. Upgrade the ceph package::
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
ssh {mon-host}
|
2012-12-30 03:54:24 +00:00
|
|
|
sudo apt-get update && sudo apt-get install ceph
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
#. Restart the monitor::
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
service ceph restart mon.{name}
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
#. Ensure the monitor has rejoined the quorum. ::
|
|
|
|
|
|
|
|
ceph mon stat
|
|
|
|
|
|
|
|
Once you have successfully upgraded a monitor, you may upgrade another monitor
|
|
|
|
until you have completed the upgrade cycle for all of your monitors.
|
|
|
|
|
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
Upgrading an OSD
|
|
|
|
----------------
|
|
|
|
|
|
|
|
To upgrade an OSD peform the following steps:
|
|
|
|
|
|
|
|
#. Upgrade the OSD package::
|
|
|
|
|
|
|
|
ssh {osd-host}
|
|
|
|
sudo apt-get update && sudo apt-get install ceph
|
|
|
|
|
|
|
|
#. Restart the OSD, where ``N`` is the OSD number::
|
|
|
|
|
|
|
|
service ceph restart osd.N
|
|
|
|
|
|
|
|
#. Ensure the upgraded OSD has rejoined the cluster::
|
|
|
|
|
|
|
|
ceph osd stat
|
|
|
|
|
|
|
|
Once you have successfully upgraded an OSD, you may upgrade another OSD until
|
|
|
|
you have completed the upgrade cycle for all of your OSDs.
|
|
|
|
|
|
|
|
|
2012-12-28 23:55:46 +00:00
|
|
|
Upgrading a Metadata Server
|
2013-05-01 00:32:15 +00:00
|
|
|
---------------------------
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
To upgrade an MDS, perform the following steps:
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
#. Upgrade the ceph package::
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
ssh {mds-host}
|
2013-04-16 20:28:18 +00:00
|
|
|
sudo apt-get update && sudo apt-get install ceph-mds
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
#. Restart the metadata server::
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
service ceph restart mds.{name}
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
#. Ensure the metadata server is up and running::
|
|
|
|
|
|
|
|
ceph mds stat
|
|
|
|
|
|
|
|
Once you have successfully upgraded a metadata, you may upgrade another metadata
|
|
|
|
server until you have completed the upgrade cycle for all of your metadata
|
|
|
|
servers.
|
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
|
2012-12-28 23:55:46 +00:00
|
|
|
Upgrading a Client
|
2013-05-01 00:32:15 +00:00
|
|
|
------------------
|
2012-12-28 23:55:46 +00:00
|
|
|
|
2012-12-30 03:54:24 +00:00
|
|
|
Once you have upgraded the packages and restarted daemons on your Ceph
|
|
|
|
cluster, we recommend upgrading ``ceph-common`` and client libraries
|
|
|
|
(``librbd1`` and ``librados2``) on your client nodes too.
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
#. Upgrade the package::
|
|
|
|
|
|
|
|
ssh {client-host}
|
2012-12-30 03:54:24 +00:00
|
|
|
apt-get update && sudo apt-get install ceph-common librados2 librbd1 python-ceph
|
2012-12-28 23:55:46 +00:00
|
|
|
|
|
|
|
#. Ensure that you have the latest version::
|
|
|
|
|
|
|
|
ceph --version
|
|
|
|
|
|
|
|
|
2013-05-01 00:32:15 +00:00
|
|
|
.. _Monitor Config Reference: ../../rados/configuration/mon-config-ref
|
|
|
|
.. _Joao's blog post: http://ceph.com/dev-notes/cephs-new-monitor-changes
|
2012-12-28 23:55:46 +00:00
|
|
|
.. _Ceph Authentication: ../../rados/operations/authentication/
|
|
|
|
.. _Ceph Authentication - Backward Compatibility: ../../rados/operations/authentication/#backward-compatibility
|