Compiling DPDKStack
|
||
|
===================
|
||
|
Ceph dpdkstack is not compiled by default.Therefore,you need to recompile and
|
||
|
enable the DPDKstack component.
|
||
|
Install dpdk and dpdk-devel,and compile do_cmake.sh -DWITH_DPDK=ON.
|
||
|
|
||
|
Setting the DPDK Network Adapter
|
||
|
================================
|
||
|
Most mainstream NICs support SR-IOV and can be virtualized into multiple VF NICs.
|
||
|
Each OSD uses some dedicated NICs through DPDK. The mon,mgr,and client use the PF NICs
|
||
|
through the POSIX protocol stack.
|
||
|
|
||
|
Load the driver on which DPDK depends:
|
||
|
modprobe vfio
|
||
|
modprobe vfio_pci
|
||
|
|
||
|
Configure Hugepage
|
||
|
vm.nr_hugepages = xxx
|
||
|
|
||
|
Configure the number of VFs based on the number of OSDs:
|
||
|
echo $numvfs > /sys/class/net/$port/device/sriov_numvfs
|
||
|
|
||
|
Binding NICs to DPDK Applications:
|
||
|
dpdk-devbind.py -b vfio-pci 0000:xx:yy.z
|
||
|
|
||
|
|
||
|
Configuring OSD DPDKStack
|
||
|
==========================
|
||
|
The DPDK RTE initialization process requires the root permission.
|
||
|
Therefore,you need to grant the root permission to ceph.
|
||
|
modify /etc/passwd to give ceph user root privilege and /var/run folder write:
|
||
|
ceph:x:0:0:Ceph storage service:/var/lib/ceph:/bin/false:/var/run
|
||
|
|
||
|
The OSD selects the NICs using ms_dpdk_devs_allowlist:
|
||
|
1)Configure a single NIC.
|
||
|
ms_dpdk_devs_allowlist=-a 0000:7d:010 or ms_dpdk_devs_allowlist=--allow=0000:7d:010
|
||
|
2)Configure the Bond Network Adapter
|
||
|
ms_dpdk_devs_allowlist=--allow=0000:7d:01.0 --allow=0000:7d:02.6
|
||
|
--vdev=net_bonding0,mode=2,slave=0000:7d:01.0,slave=0000:7d:02.6
|
||
|
|
||
|
DPDK-related configuration items are as follows:
|
||
|
[osd]
|
||
|
ms_type=async+dpdk
|
||
|
ms_async_op_threads=1
|
||
|
|
||
|
ms_dpdk_port_id=0
|
||
|
ms_dpdk_gateway_ipv4_addr=172.19.36.1
|
||
|
ms_dpdk_netmask_ipv4_addr=255.255.255.0
|
||
|
ms_dpdk_hugepages=/dev/hugepages
|
||
|
ms_dpdk_hw_flow_control=false
|
||
|
ms_dpdk_lro=false
|
||
|
ms_dpdk_enable_tso=false
|
||
|
ms_dpdk_hw_queue_weight=1
|
||
|
ms_dpdk_memory_channel=2
|
||
|
ms_dpdk_debug_allow_loopback = true
|
||
|
|
||
|
[osd.x]
|
||
|
ms_dpdk_coremask=0xf0
|
||
|
ms_dpdk_host_ipv4_addr=172.19.36.51
|
||
|
public_addr=172.19.36.51
|
||
|
cluster_addr=172.19.36.51
|
||
|
ms_dpdk_devs_allowlist=--allow=0000:7d:01.1
|
||
|
|
||
|
Debug and Optimization
|
||
|
======================
|
||
|
Locate faults based on logs and adjust logs to a proper level:
|
||
|
debug_dpdk=xx
|
||
|
debug_ms=xx
|
||
|
if the log contains a large number of retransmit messages,reduce the value of ms_dpdk_tcp_wmem.
|
||
|
|
||
|
Run the perf dump command to view DPDKStack statistics:
|
||
|
ceph daemon osd.$i perf dump | grep dpdk
|
||
|
if the "dpdk_device_receive_nombuf_errors" keeps increasing,check whether the
|
||
|
throttling exceeds the limit:
|
||
|
ceph daemon osd.$i perf dump | grep throttle-osd_client -A 7 | grep "get_or_fail_fail"
|
||
|
ceph daemon osd.$i perf dump | grep throttle-msgr_dispatch_throttler -A 7 | grep "get_or_fail_fail"
|
||
|
if the throttling exceeds the threshold,increase the throttling threshold or
|
||
|
disable the throttling.
|
||
|
|
||
|
Check whether the network adapter is faulty or abnormal.Run the following
|
||
|
command to obtain the network adapter status and statistics:
|
||
|
ceph daemon osd.$i show_pmd_stats
|
||
|
ceph daemon osd.$i show_pmd_xstats
|
||
|
|
||
|
Some DPDK versions(eg.dpdk-20.11-3.e18.aarch64)or NIC TSOs are abnormal,
|
||
|
try disabling tso:
|
||
|
ms_dpdk_enable_tso=false
|
||
|
|
||
|
if VF NICs support multiple queues,more NIC queues can be allocated to a
|
||
|
single core to improve performance:
|
||
|
ms_dpdk_hw_queues_per_qp=4
|
||
|
|
||
|
|
||
|
Status and Future Work
|
||
|
======================
|
||
|
Compared with POSIX Stack,In the multi-concurrency test,DPDKStack has the same
|
||
|
4K random write performance,8K random write performance is improved by 28%,and
|
||
|
1 MB packets are unstable.In the single-latency test,the 4K and 8K random write
|
||
|
latency is reduced by 15%(the lower the latency is,the better).
|
||
|
|
||
|
At a high level,our future work plan is:
|
||
|
OSD multiple network support (public network and cluster network)
|
||
|
The public and cluster network adapters can be configured.When connecting or
|
||
|
listening,the public or cluster network adapters can be selected based on the
|
||
|
IP address.During msgr-work initialization,initialize both the public and cluster
|
||
|
network adapters and create two DPDKQueuePairs.
|